Laserfiche WebLink
that are recessed at least one inch rather than being flush with the facade. If the building is a <br />one story design and the first floor elevation exceeds twelve feet, then only the first twelve <br />feet shall be included in calculating the facade area. <br />The proposed CVS Pharmacy has substantially more glass than the previously approved plan. <br />The east facade, facing Lexington Avenue, would have 52 percent glass. The west facade, <br />facing County Road E, would have 34 percent, and the south facade would have 49 percent. <br />The Code allows reductions in the required amount of glass for buildings with a use or <br />function that does not readily allow windows (e.g. cooler or freezer areas, mechanical rooms, <br />security areas, storage areas). However, the architectural detailing must be provided by the <br />use of upper level windows, which may include the partial use of simulated windows, or <br />architectural detailing that provides arches, patterning, recesses, and shadowing that provide <br />aesthetic interest. Architectural detailing may include such things as change in materials, <br />change in color and other significant visual relief provided in a manner or at intervals in <br />keeping with the size, mass, and scale of the wall. The applicant has revised the building to <br />add architectural detailing and recesses around four sides, and enlarged the building at the <br />corner of County Road E and Lexington to mimic the main entrance to the south. <br />3. Sign Code <br />A. Wall and Monument Signage <br />The application does not include a signage plan for the development. The previously <br />approved Final PUD for Phase I allowed 99 square feet of wall signage on Building 1 (an <br />excess of 19 square feet from the Code allowance), all other provisions of the Sign Code are <br />required to be met. Staff understands that CVS Pharmacy is not requesting any signage <br />above and beyond 99 square feet, and will design their signage plan to meet this provision. <br />In the B -2 District each property is allowed one 100 square foot monument sign, not to <br />exceed 16 feet in height. Properties that have more than one street access are allowed an <br />additional 50 square foot monument sign. The CVS Pharmacy proposal would be required to <br />meet this requirement of the Code. <br />B. Gateway Sign <br />As part of their project, the applicants have agreed to partner with the City on implementing <br />a gateway sign. The applicant would construct the sign foundation, support structure (i.e. <br />columns), and put in the landscaping shown on the landscaping plan. The City would <br />provide the sign face structure, sign lighting, and would be responsible for future <br />maintenance of the sign, lighting, and landscaping. While this partnership is contingent upon <br />approval of the proposal, the City could not approve or deny the application due to this <br />City of Arden Hills <br />Planning Commission Meeting for August 3, 2011 <br />P: IPlanning1Planning Cases12011111 -016 - Arden Plaza - PUD Amendment (Pending)I08-03-11 - PC Report - Arden Plaza - PUD <br />Amendment.docx <br />Page 7of10 <br />