My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
11-28-12-PC
ArdenHills
>
Administration
>
Commissions, Committees, and Boards
>
Planning Commission
>
Planning Commission Packets
>
2010-2019
>
PC Packets 2012
>
11-28-12-PC
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/9/2024 12:22:27 AM
Creation date
11/30/2012 3:52:46 PM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
54
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DRAWN BY: DESIGN BY: <br /> LEGEND A.G. A.G. <br /> CHCKD BY: PROJ.NO. <br /> EXISTING LIGHT POLE �y)� PROPOSED STORM SEWER C.W.P. 10-1292 <br /> 0 EXISTING UTILITY POLE o- -- PROPOSED DRAINTILE 8:CLEAN-OUTS ORIGINAL DATE: <br /> 0 EXISTING WATER VALVE NOVEMBER 5,2012 <br /> 1 -91 PROPOSED 1-FT CONTOURS <br /> <j EXISTING HYDRANT w <br /> EXISTING STREET SIGN PROPOSED SILT FENCE <br /> G EXISTING STORM MANHOLE PROPOSED RIP-RAP <br /> 0 <br /> ® EXISTING SANITARY MANHOLE PROPOSED FILTRATION MEDIA w <br /> Q EXISTING TELEPHONE MANHOLE <br /> w- EXISTING OVERHEAD ELECTRIC X40.90 PROPOSED SPOT ELEVATION(+900) o- <br /> O <br /> (GUTIERUNE,BITUMINOUS d <br /> ----mow EXISTING UNDERGROUND ELECTRIC SURFACE,OR GROUND SURFACE <br /> UNLESS 07HERMSE NOTED) Z <br /> --- �. EXISTING UNDERGROUND TELEPHONE p <br /> PROPOSED INLET PROTECTION = <br /> o EXISTING GAS O W <br /> WARNINGII EXISTING SANITARY SEWER a Z <br /> BURIED FIBER OPTIC CABLE » EXISTING STORM SEWER w w <br /> FIELD VERIFY LOCATION PRIOR W EXISTING WATERMAIN O I¢ <br /> TO ANY EXCAVATIONS EXISTING SPOT ELEVATION GUTTEROf <br /> O <br /> EXISTING SPOT ELEVATION rn <br /> > F <br /> W u <br /> EXISTING 1-FT CONTOURS w <br /> \ \ ` HM-FIELD VERIFY �@� EXISTING TREE H No <br /> N,SZE AND INVERT <br /> ELEVATIONS OF EXSITIN0024•CAST IRON P1E <br /> UNDER RAINROAD AND PROVIDE INFORMATION TO <br /> \ ENGINEER-CLEAN-OUT PIPE TO ALLOW FOR co <br /> (2'X 1'_) \ \\ FREE-ROWING CONDITIONS y z 3 ao <br /> IM 401w1 I ¢w w O1 <br /> INV 3 40 �v- 0'S2 g v <br /> NEENAH R-3087V'' ,^ �� z i 7 w <br /> \ \ \ EDGE OF WATER g 5.'.W.d z <br /> EXISTING 24'CIP /I AUGUST 2, 2010 m w o w d <br /> FIBER INV 933.83 I W <br /> .WARN/NCPSICN ABLE // I ¢z a S Y <br /> / �oaw <br /> n ` �C 12"X ') v �` 18'INV APRON / j r`w,z-U' Q N <br /> lu Ja z o <br /> INV9 40 ^ }Z Q o <br /> a NEENAH R-3 <br /> O0 <br /> 7V �. \ \'^�`_` FOUND IPE NOT <br /> U z <br /> EXISTING 24"CIP / / m w O <br /> INV 934.03 / / ¢22 <br /> ocj ( / \\ \\�� \ \ EXIS1)N / I // ircw <br /> •) N <br /> RIM 40.40 NM 93B.40 <br /> INV 935.80-5 \ 51'-18'ROP <br /> MH 17(0-48") NEEN RR-3067V O 0.89x <br /> R \ / <br /> AH -308N \\ --U1V-935.w �� \ -- \\ \_• _a / <br /> 2Y-30'RCP O 0.371E \ \\ __ <br /> IN <br /> 55'-30'PIPE - -_ -� I a; DPRC EVS / <br /> IN 9JBA5 7067V O 0.27x \\- \ I OUTLET STRUCTURE \ SI CggLE TiNG P / <br /> ,� \•~ \\ I (• (ALSO SEE DETAIL) \ DND EXISTING <br /> \\\ \\ •\ \1.�RC APRON I 1• I I NV 939.60-NE WALK H <br /> 141'- INV 93J.00 __/ I INV 833.20-SW \ ^ = N <br /> o. <br /> 12W-18'PIPE O 0.237E 128'-24'PIPE O 0.20>< 128-24 PIPE O 0.28x I-Ra'' <br /> UNKNOWN M.H. / \ Lu <br /> RETAINING WALL Z <br /> M 5( ) RIM=942. \ ��------�/ / I O a <br /> CBMH 0 M4B' 14 \ / r------------ <br /> OVERHANG / <br /> RIM 4b <br /> NV 938:5-N m L-_- -----• I 0 3 F <br /> OA IIIIIIIIAIIIII <br /> NV 938.35-E.w <br /> /10(M4B' -.c---_.c __ .c _ c __..c----.c__ 944, <br /> 4 NM BJ9.70 __ / / RIM=INV-9 Q WC <br /> �OUMPSTER 81 <br /> CBMH 13(�w�•) � INV 9J8.15 _ STORM M.H�/ / I N.E.INV.=923.6 Ej� <br /> RIM 940.00 EENAH R-308N RIM=944.60 <br /> INV 935.75 140'-18'PIPE O 0.32>< <br /> A, RI MH 0.(M4B') 15"E.INV.=93B.fi <br /> INV 940.SU NEENAH R-3TXi7V A.C.UNIT (FOR FUTURE DEVELOPMENT) 15"W.INV.938.4 <br /> INV 938.R-2554 95 END NV 936.60 <br /> NEENAH BULKHEAD END OF PIPE / <br /> Z " FURIRE PROPERTY LINE // I \\ SAN.M.H. <br /> // 1201 WEST COUNTY ROAD E" <br /> 2-4 STORY BRICK BUKDIRC-------- --��--� / RIM S.IN 3 PREPARED FOR: <br /> AUTO SPRINKLER BUILDING HEIGHT ABOVE GRADE 18 FEET WET SIDE 42 FEET EAST SIDE ELEC.TRANS. STORM M.H� a I 15"S.INV.=923.fi <br /> m RIM=944.66 i I IS"N.E.INV.=923.6 ROB <br /> �p BUILDING FOOTPRINT AREA 5(369 SO.FT. 15"S.E.INV.=940.6 <br /> 2 <br /> z .w.r CB/B(2'x S) I 15"W.INV.=990.1 OO <br /> INV 93.S DAVIDSON <br /> x I7 I I 360 S.F. AY <br /> w � NEENAH R-JOBN0 <br /> O I AUTOCOVERED CANOPY(TO BE REMOVED) SIGNAGE �J <br /> FNT(1 <br /> O / AUTO SPRINKLER <br /> S+ / LXIS ING Z <br /> i� B-12 FT SIDEWALK EASEMENT ^� WAL EXISTING I' <br /> A /W / \ BENCH <br /> 12-FT WIDE PUBLIC STREET 'r x <br /> I / n AND UTILITIES EASEMENT / I W <br /> _-2SO\� CONSTRUCT MANHOLE OVER 356 FEET 2� \ / I / J SITE PLANNING <br /> 111 IH 1(��•) \/ 8 ENGINEERING <br /> CBM <br /> po //II <br /> r RIM 840.00 I-T-T--I--��-T-�-� <br /> SIGN [� 11 -INV�38.pp - -- -- --_- __IJ 11L1�-11 L1_ 11 LIJ- �7I�. --- <br /> i_ H , Lv NEENAH It=308N - --- �w --- <br /> _ -- <br /> ------- c-- -mowr <br /> ELEC.TRANS. -- ----- - - - - -- �� I L � �� <br /> c�-----� ELEC.BO% IV <br /> OWE <br /> -"- n EN6INEERIN6,INC. <br /> TEX 1 "VCP SAN �< - nX<12"VCPAN < < 6E%10"VCP SAN �, c c <- c ^ " " �-EXISTING / I SUITE 110 LAKEDRIVE <br /> -w � �w-- NM �' (- w- w_y w L' w w w w w n w ww " ww w w \ LINO LAKES,MN 55014 <br /> M�w TRAFFIC <br /> -� rw w PHONE:651 361-6210 <br /> -• c --r�w EX HYDRANT w-�Ir wEX 6"W.M. E%HYDRANT \ LIGHT / ( ) <br /> w <br /> E%6 W.M. SAN_M_H.�� 11 >` FAX:)851)361-8701 <br /> \ ( RIM=941.23 A 111 - <br /> 6"N.INV.=928.6 11 1 �N_M-H_ v <br /> 12"S.INV.=928.3 I 1 �� REPLACE 8'PIPE - I RIM=943.37 / <br /> `/--UNDERGROUND ELEC.UTILITY 111 \ WITH le PIPE 1 10"w.INV=929.9 .J rJORTI••I <br /> AND PEDESTRIAN WAY EASE. r I vo--- �.--- �. --- -- _ <br /> PER DOC.NO.2114719 WEST 1 jCOUNTY ROAD j 11,E <br /> 1 <br /> II 1 _STORM M.H. 0 20 40 <br /> RIM=.INV- 1'15AN_M_H.4 <br /> 6-N.INV.=935.8 RIM.M H.4 <br /> SAN_M_IT 15"S.INV.=935.9 8"S.INV.=926.4 <br /> 11`TORM M.H. 10"E.INV.=928.2 <br /> RIM=938.46 11NCH=90 FEET <br /> UTILITY PLAN 2"N.INV.9276 RIM=."? 8"N.INV.=928. <br /> 12' 928.8 <br /> E.INV.=926.9 6"W.?�?INV.=92].6 12"W.INV.=928.2 <br /> 12"W.INV=926.R 80TTOM INV.=926.3 <br /> THE ARDEN REVELOPMENT CZ <br />
The URL can be used to link to this page
Your browser does not support the video tag.