Laserfiche WebLink
ARDEN HILLS CITY COUNCIL—OCTOBER 28, 2013 4 <br /> to authorize execution of all necessary documents contained therein. The <br /> motion carried unanimously (5-0). <br /> 6. PULLED CONSENT ITEMS <br /> A. Planning Case#13-016—Variance— 1226 Ingerson Road <br /> Councilmember Holmes requested further information regarding the variance requested. <br /> City Planner Streff stated the applicant has requested two (2) variances for the proposed project <br /> located at 1226 Ingerson Road. <br /> 1) The first variance is being requested to exceed the Floor Area Ratio (FAR) by 313 <br /> square feet. <br /> 2) The second variance is being requested to allow flexibility in the setback <br /> regulations to expand the existing deck, construct a front entrance overhang and <br /> add sunshades to the south facing elevations of the home. <br /> City Planner Streff indicated the applicants own the property located at 1226 Ingerson Road, <br /> which is zoned R-1 Single Family Residential. The property is generally positioned north of Lake <br /> Josephine, south of Ingerson Road, east of Snelling Avenue/Highway 51 and west of Lexington <br /> Avenue. The existing structure is a two-story home on slab with no basement with its front access <br /> positioned along Ingerson Road to the north. The topography on the site is fairly flat, slopping <br /> approximately two (2) feet from north to south. Ingerson Court curves to the north, wrapping <br /> around the west side of the parcel, where it intersects with Ingerson Road creating a triangular <br /> shaped lot, which for zoning purposes has three (3) front yards along the north, south and west <br /> sides of the lot. On this property the Zoning Code requires a forty (40) foot front yard setback on <br /> the north, south and west sides. The existing structure encroaches approximately fourteen(14) feet <br /> along Ingerson Road and thirty-three (33) feet along Ingerson Court. The remaining yard on the <br /> east side of the lot has a typical side yard setback of ten (10) feet. The residential structure has <br /> been determined to be non-conforming as it relates to the setback requirements within the R-1 <br /> Single Family Residential District. <br /> City Planner Streff stated the property owner is proposing to construct a 787 square foot third <br /> floor addition to the existing home. The proposed addition would exceed the Floor Area Ratio <br /> (FAR) by 313 square feet. For this particular lot, a maximum principle structure size of 2,977 <br /> square feet is permitted under the Zoning Code. The proposed project would expand the structure <br /> to 3,290 square feet. A variance is being requested to increase the FAR by 313 square feet. <br /> City Planner Streff explained a deck addition is being proposed on the southern side of the <br /> structure along Ingerson Court. The deck addition would expand approximately three (3) feet <br /> along the eastern half of the south fagade and four (4) to four and one half (4.5) feet along the <br /> western half of the south facade. Sunscreens are also being proposed along the entire southern <br /> fagade that would mirror the deck's dimensions. The deck and sunscreens would encroach further <br /> into the existing setback along Ingerson Court than the existing structure. At its closest point the <br /> deck would be approximately two (2) feet from the south property line. A variance is being <br /> requested to encroach an additional four and one half(4.5) feet into the existing setback. <br />