Laserfiche WebLink
T (800) 236-6800 F (262) 504-5415US: lighting.cree.com/lighting T (800) 473-1234 F (800) 890-7507Canada: www.cree.com/canada <br />Product Specifications <br />CONSTRUCTION & MATERIALS <br />• Slim, low profile, minimizing wind load requirements <br />• Luminaire sides are rugged die cast aluminum with integral, <br />weathertight LED driver compartment, spun vented cover, and high <br />performance aluminum heat sinks <br />• R3 spider mount hub slip-fits over a 2.375" (60mm) to 3" (76mm) O.D. <br />steel or aluminum tenon or pole and secures with eight set screws <br />• R4 spider mount fits directly inside 4" (102mm) square pole and secures <br />to pole with four set screws <br />• R5 spider mount fits directly inside of a 5" (127mm) round pole to provide <br />a clean hardware-less outer appearance <br />• Includes leaf/debris guard <br />• Exclusive Colorfast DeltaGuard® finish features an E-Coat epoxy primer <br />with an ultra-durable powder topcoat, providing excellent resistance to <br />corrosion, ultraviolet degradation and abrasion. Black, bronze, silver, <br />and white are available <br />• Weight: See Dimensions and Weight charts on pages 1 and 14 <br />ELECTRICAL SYSTEM <br />• Input Voltage : 120-277V or 347-480V, 50/60Hz, Class 1 drivers <br />• Power Factor : > 0.9 at full load <br />• Total Harmonic Distortion : < 20% at full load <br />• 10V Source Current: 40-80 LEDs: 0.15mA; 100-120 LEDs: 0.30mA <br />• Integral 10kV surge suppression protection standard <br />• When code dictates fusing, a slow blow fuse or type C/D breaker should <br />be used to address inrush current <br />REGULATORY & VOLUNTARY QUALIFICATIONS <br />• cULus Listed <br />• Suitable for wet locations <br />• Meets FCC Part 15, Subpart B, Class A standards for conducted and <br />radiated emissions <br />• Enclosure rated IP66 per IEC 60529 when ordered without P option <br />• Certified to ANSI C136.31-2001, 1.5G normal vibration standards when <br />ordered with R3, R4 and R5 mounts <br />• 10kV surge suppression protection tested in accordance with IEEE/ANSI <br />C62.41.2 <br />• Luminaire and finish endurance tested to withstand 5,000 hours of <br />elevated ambient salt fog conditions as defined in ASTM Standard B 117 <br />• DLC qualified. Exceptions apply when ordered with full backlight control <br />or 3MP optic. Please refer to www.designlights.org/QPL for most current <br />information <br />• Meets Buy American requirements within ARRA <br />Cree Edge™ LED Area Luminaire – Round <br />Electrical Data* <br />LED Count <br />(x10) <br />System <br />Watts <br />120-480V <br />Total Current (A) <br />120V 208V 240V 277V 347V 480V <br />350mA <br />04 46 0.36 0.23 0.21 0.20 0.15 0.12 <br />06 66 0.52 0.31 0.28 0.26 0.20 0.15 <br />08 90 0.75 0.44 0.38 0.34 0.26 0.20 <br />10 110 0.92 0.53 0.47 0.41 0.32 0.24 <br />12 130 1.10 0.63 0.55 0.48 0.38 0.28 <br />525mA <br />04 70 0.58 0.34 0.31 0.28 0.21 0.16 <br />06 101 0.84 0.49 0.43 0.38 0.30 0.22 <br />08 133 1.13 0.66 0.58 0.51 0.39 0.28 <br />10 171 1.43 0.83 0.74 0.66 0.50 0.38 <br />12 202 1.69 0.98 0.86 0.77 0.59 0.44 <br />700mA <br />04 93 0.78 0.46 0.40 0.36 0.27 0.20 <br />06 134 1.14 0.65 0.57 0.50 0.39 0.29 <br />* Electrical data at 25˚C (77˚F). Actual wattage may differ by +/- 10% when operating between 120-480V +/- 10% <br />Recommended Cree Edge™ Series Lumen Maintenance Factors (LMF)1 <br />Ambient Initial <br />LMF <br />25K hr <br />Projected2 <br />LMF <br />50K hr <br />Projected2 <br />LMF <br />75K hr <br />Calculated3 <br />LMF <br />100K hr <br />Calculated3 <br />LMF <br />5˚C <br />(41˚F)1.04 1.01 0.99 0.98 0.96 <br />10˚C <br />(50˚F)1.03 1.00 0.98 0.97 0.95 <br />15˚C <br />(59˚F)1.02 0.99 0.97 0.96 0.94 <br />20˚C <br />(68˚F)1.01 0.98 0.96 0.95 0.93 <br />25˚C <br />(77˚F)1.00 0.97 0.95 0.94 0.92 <br />1 Lumen maintenance values at 25˚C are calculated per TM-21 based on LM-80 data and in-situ luminaire testing <br />2 In accordance with IESNA TM-21-11, Projected Values represent interpolated value based on time durations that are <br /> within six times (6X) the IESNA LM-80-08 total test duration (in hours) for the device under testing ((DUT) i.e. the <br /> packaged LED chip) <br />3 In accordance with IESNA TM-21-11, Calculated Values represent time durations that exceed six times (6X) the IESNA <br /> LM-80-08 total test duration (in hours) for the device under testing ((DUT) i.e. the packaged LED chip)