Laserfiche WebLink
<br />_____________________________________________________________________________________________ <br />City of Arden Hills <br />City Council Meeting for August 21, 2017 <br />P:\Planning\Planning Cases\2017\PC 17-021 - Pulte Homes - Concept Plan Review - Parkshore Drive <br />Properties\Memos_Reports_17-021 <br /> <br />Page 4 of 5 <br />Amendment would also be required to change the Future Land Use designation of the site to <br />High Density Residential, which supports densities of 9 to 12 units per acre. <br /> <br />Additional flexibility would be needed in the areas of impervious surface coverage, structure <br />setbacks, and building height. The maximum impervious surface coverage permitted in the R-3 <br />District is 35 percent. As a whole, the project would have an impervious surface coverage of <br />58.9 percent. Pulte has stated that the proposed amount of impervious surface is typical for this <br />type of townhome project and has expressed a willingness to explore creative stormwater <br />management solutions to satisfy the concerns of the City and the Rice Creek Watershed District. <br /> <br />The development would also deviate from the R-3 District setback requirements. A 40-foot front <br />yard setback is required from the Parkshore Drive and Old Highway 10 right-of-way lines. In <br />discussions with Pulte, staff recommended that the townhomes be located closer to Parkshore <br />Drive considering the front of the buildings will be oriented towards the perimeter and private <br />garages would be rear-loaded. The concept plan indicates a setback of 15 feet from the Parkshore <br />Drive and Old Highway 10 property lines. In shifting the buildings closer to Parkshore Drive, a <br />larger setback from the adjacent single-family residential property could be accommodated. The <br />closest townhome to the southeast side property line would be 40 feet. The R-3 District requires <br />a minimum side yard setback of 5 feet. <br /> <br />The final area where flexibility would be needed is in building height. The maximum height <br />permitted in the R-3 District is 35 feet. The townhomes would be three stories and Pulte expects <br />them to have a height of up to 39 feet. The additional building height is requested to allow for a <br />steeper roof line that can accommodate more uses within the attic space. <br /> <br />Below is a table of the R-3 District performance standards and which standards would likely be <br />exceeded by the proposal: <br /> <br />Performance Standards <br />R-3 District <br />Requirements Pulte Proposal <br />Maximum Building Height 35 feet 39 feet <br />Maximum Floor Area Ratio 0.3 To Be Determined <br />Maximum Lot Coverage by Structures 25% 25.2% <br />Maximum Impervious Surface 35% 58.9% <br />Minimum Landscape Lot Area 65% 41.1% <br />Minimum Principle Building Setback <br />Front Yard (Parkshore and Old Hwy 10) 40 feet 15 feet <br />Rear Yard (Interstate 694) 30 feet 30 feet <br />Side Yard (East and West Lot Lines) <br />5 feet minimum/ <br />15 feet total <br />40 feet (East Lot Line) <br />15 feet (West Lot Line) <br /> <br /> <br />