My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
09-25-17-R
ArdenHills
>
Administration
>
City Council
>
City Council Packets
>
2010-2019
>
2017
>
09-25-17-R
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/22/2017 11:54:32 AM
Creation date
9/22/2017 11:32:54 AM
Metadata
Fields
Template:
General
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
417
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br /> <br /> <br />Geotechnical Report <br />2018 PMP Streets <br />Arden Hills, Minnesota <br />WSB Project No. 010111-000 Page 9 <br /> <br />4.8 Cold Weather Construction <br />It is our understanding that construction is unlikely to occur during the winter months. However, if the <br />construction does continue into the winter months we recommend the following guidelines. <br /> <br />Only unfrozen fill should be used. Placement of fill must not be permitted on frozen soil. <br /> <br />4.9 Field Observation and Testing <br />The soil conditions illustrated on the Logs of Test Borings in Appendix A are indicative of the conditions <br />only at the boring locations. <br /> <br />WSB also recommends a representative number of field density tests be taken in all engineered fill and <br />backfill placed to aid in judging its suitability. Fill placement and compaction should be monitored and <br />tested to determine that the resulting fill and backfill conforms to specified density, strength or <br />compressibility requirements. We recommend at least one compaction test for every 300 linear feet of <br />utility trench, at vertical intervals not exceeding 2 feet. Prior to use, any proposed fill and backfill material <br />should be submitted to the WSB laboratory for testing to verify compliance with recommendations and <br />project specifications. <br /> <br />Dynamic Cone Penetrometer (DCP) tests can be completed in the aggregate base in lieu of density <br />testing. W e recommend following MnDOT Specification 2211-3. <br /> <br />WSB would be pleased to provide the necessary field observation, monitoring and testing services during <br />construction. <br /> <br />4.10 Plan Review and Remarks <br />The observations, recommendations and conclusions described in this report are based primarily on <br />information provided to WSB, obtained from our subsurface exploration, our experience, several <br />necessary assumptions and the scopes of service developed for this project and are for the sole us e of <br />our client. We recommend that WSB be retained to perform a review of final design drawing and <br />specifications to evaluate that the geotechnical engineering report has not been misinterpreted. Should <br />there be any changes in the design related to this project or if there are any uncertainties in the report we <br />should be notified. We would be pleased to review any project changes and modify the <br />recommendations in this report (if necessary) or provide any clarification in writing. <br /> <br />The entire report should be kept together; for example, boring logs should not be removed and placed in <br />the specifications separately. <br /> <br />The boring logs and related information included in this report are indicators of the subsurface conditions <br />only at the specific locations indicated on the Soil Boring Exhibit and times noted on the Logs of Test <br />Boring sheets in Appendix A. The subsurface conditions, including groundwater levels, at other <br />locations on the site may differ significantly from conditions that existed at the time of sampling and at the <br />boring locations. <br /> <br />The test borings were put down by WSB solely to obtain indications of subsurface conditions as part of a <br />geotechnical exploration program. No services were performed to evaluate subsurface environmental <br />conditions. <br /> <br />WSB has not performed any observations, investigations, studies or testing that is not specifically listed in <br />the scope of service. WSB shall not be liable for failing to discover any condition whose discovery <br />required the performance of services not authorized by the Agreement.
The URL can be used to link to this page
Your browser does not support the video tag.