Laserfiche WebLink
Catalog Number:Project No. <br />Project Name <br />Type: <br />T (800) 236-6800 F (262) 504-5415US: www.cree.com/lighting T (800) 473-1234 F (800) 890-7507Canada: www.cree.com/canada <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />Product Specifications <br />CREE TRUEWHITE® TECHNOLOGY <br />A revolutionary way to generate high-quality white light, Cree TrueWhite® Technology is a <br />patented approach that delivers an exclusive combination of 90+ CRI, beautiful light <br />characteristics and lifelong color consistency, all while maintaining high luminous <br />efficacy – a true no compromise solution. <br />CONSTRUCTION & MATERIALS <br />• Slim, low profile, minimizing wind load <br />• Luminaire sides are rugged die cast aluminum with integral, weathertight LED driver compartments and high performance heat sinks <br />• Adjustable arm that mounts to a horizontal or vertical 2" (51mm) IP, 2.375-2.50" (60-64mm) O.D. steel tenon. Tenon length must be a minimum of 3.75" (95mm) <br />• Surface-mount directly to a vertical or horizontal surface with direct mount bracket (refer to Tenons and Brackets table on page 12) <br />• Luminaire may be field adjusted for use in uplight position. Please refer to installation instructions for details <br />• Extruded aluminum adjustable mounting shaft <br />• Luminaire is adjustable from horizontal 90˚ towards pole and 120˚ away from pole <br />• Exclusive Colorfast DeltaGuard® finish features an E-Coat epoxy primer with an ultra-durable powder topcoat, providing excellent resistance to corrosion, ultraviolet degradation and abrasion. Silver, bronze, black, and white are available <br />• Weight: See weight charts on pages 1 and 13 <br />ELECTRICAL SYSTEM <br />• Input Voltage : 120-277V or 347-480V, 50/60Hz, Class 1 drivers <br />• Power Factor : > 0.9 at full load <br />• Total Harmonic Distortion : < 20% at full load <br />• Integral 10kV surge suppression protection standard <br />• To address inrush current, slow blow fuse or type C/D breaker should be used <br />• Maximum 10V Source Current: 120 LED: 0.40mA; 240 LED: 0.80mA <br />REGULATORY & VOLUNTARY QUALIFICATIONS <br />• cULus Listed <br />• Suitable for wet locations <br />• Consult factory for CE Certified products <br />• 10kV surge suppression protection tested in accordance with IEEE/ANSI C62.41.2 <br />• Meets FCC Part 15, Subpart B, Class A standards for conducted and radiated emissions <br />• Certified to ANSI C136.31-2001, 3G bridge and overpass vibration standards <br />• DLC qualified. Exceptions apply when ordered with backlight control, 5000K CCT with 1000mA drive current, or 5000K CCT with 700mA drive current and 2M, 3M or 70 optics. Please refer to www.designlights.org/QPL for most current information <br />• Luminaire and finish endurance tested to withstand 5,000 hours of elevated ambient salt fog conditions as defined in ASTM Standard B 117 <br />• Meets Buy American requirements within ARRA <br />• Dark Sky Friendly, IDA Approved. Please refer to www.darksky.org/ for most current information <br />• RoHS compliant. Consult factory for additional details <br />Recommended Cree® Edge High Output Series Lumen Maintenance Factors (LMF)1 <br />Ambient Initial <br />LMF <br />25K hr <br />Projected2 <br />LMF <br />50K hr <br />Projected2 <br />LMF <br />75K hr <br />Calculated3 <br />LMF <br />100K hr <br />Calculated3 <br />LMF <br />5˚C <br />(41˚F)1.04 0.99 0.97 0.95 0.93 <br />10˚C <br />(50˚F)1.03 0.98 0.96 0.94 0.92 <br />15˚C <br />(59˚F)1.02 0.97 0.95 0.93 0.91 <br />20˚C <br />(68˚F)1.01 0.96 0.94 0.92 0.90 <br />25˚C <br />(77˚F)1.00 0.95 0.93 0.91 0.89 <br />1 Lumen maintenance values at 25˚C are calculated per TM-21 based on LM-80 data and in-situ luminaire testing <br />2 In accordance with IESNA TM-21-11, Projected Values represent interpolated value based on time durations that are within six times <br /> (6X) the IESNA LM-80-08 total test duration (in hours) for the device under testing ((DUT) i.e. the packaged LED chip) <br />3 In accordance with IESNA TM-21-11, Calculated Values represent time durations that exceed six times (6X) the IESNA LM-80-08 total <br /> test duration (in hours) for the device under testing ((DUT) i.e. the packaged LED chip) <br />Electrical Data* <br />LED Count <br />(x10) <br />System Watts <br />120-480V <br />Total Current <br />120V 208V 240V 277V 347V 480V <br />700mA <br />12 267 2.24 1.29 1.12 0.99 0.80 0.58 <br />24 533 4.49 2.57 2.24 1.97 1.62 1.16 <br />1000mA <br />12 421 3.61 2.06 1.80 1.61 1.25 0.90 <br />24 831 7.16 4.04 3.54 3.14 2.50 1.81 <br />Cree Edge™ LED High Output Area/Flood Luminaire <br />* Electrical data at 25˚C (77˚F). Actual wattage may differ by +/- 10% when operating between 120-480V +/- 10%