Laserfiche WebLink
DEMOLITION PLAN KEYED NOTES <br />DE01 FLOOR TRENCH TO REMAIN <br />DE02 DEMOLISH WINDOW <br />DE03 FIXED CASEWORK ISLAND TO REMAIN <br />DE04 CASEWORK AND FUME HOOD TO REMAIN <br />DE05 DEMOLISH MASONRY RETAINING WALL, SEE CIVIL <br />DE06 DEMOLISH WINDOW STOOL, WINDOW TO REMAIN <br />DE07 DEMOLISH WINDOW AND STOOL <br />DE08 NOT USED <br />NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN OR BID PACK <br />DEMOLITION GENERAL NOTES <br />DESIGN BUILDER SHALL COORDINATE ALL DEMOLITION WORK, PHASING AND <br />SEQUENCING WITH THE OWNER. ANY INFORMATION REGARDING SEQUENCING <br />PROVIDED IN THESE DOCUMENTS IS FOR ARCHITECT - OWNER PLANNING <br />PURPOSES ONLY, UNLESS NOTED OTHERWISE. <br />DESIGN BUILDER SHALL BE RESPONSIBLE FOR COORDINATING WITH ALL <br />TRADES FOR THE DEMOLITION WORK REQUIRED FOR THIS PROJECT. <br />WHERE PARTITIONS ARE INDICATED TO BE REMOVED, REMOVE PARTITION <br />ALONG WITH ALL ITEMS CONTAINED WITHIN, INCLUDING DOORS, FRAMES, <br />HARDWARE, SIDELIGHTS, WINDOWS, MECHANICAL AND ELECTRICAL <br />EQUIPMENT, ETC. TO STRUCTURE ABOVE, UNLESS NOTED OTHERWISE. <br />WHERE FLOOR FINISH IS INDICATED TO BE DEMOLISHED, REMOVE FINISH TO <br />FLOOR SLAB AS REQUIRED AND PREPARE SLAB SURFACE FOR SCHEDULED <br />FINISHES WITHIN AREA TO BE REMODELED, UNLESS NOTED OTHERWISE. SEE <br />FINISH SCHEDULE FOR EXISTING FLOOR FINISHES TO REMAIN UNDISTURBED. <br />WHERE CEILING IS INDICATED TO BE DEMOLISHED, REMOVE CEILING <br />SUSPENSION SYSTEM ALONG WITH ALL ASSOCIATED MECHANICAL AND <br />ELECTRICAL ITEMS, UNLESS NOTED OTHERWISE. SEE MECHANICAL AND <br />ELECTRICAL DRAWINGS FOR EXTENT OF CONDUIT, PIPING AND DUCTWORK <br />DEMOLITION WITHIN AREA TO BE REMODELED. <br />WHERE INDICATED, REMOVE ALL WALL/PARTITION EXISTING FINISHES AND <br />PREPARE THE SURFACES FOR SCHEDULED FINISHES, SEE FINISH SCHEDULE <br />FOR FINISHES. <br />ALL DISTURBED AREAS, WALLS, PARTITIONS, FLOORS, ETC, DAMAGED BY <br />DEMOLITION WORK SHALL BE PATCHED TO MATCH ADJACENT AREA. <br />OWNER RESERVES THE RIGHT OF FIRST REFUSAL OF ALL SALVAGED ITEMS <br />SUCH AS: DOORS, LIGHT FIXTURES, PLUMBING FIXTURES ETC. <br />SALVAGED ITEMS SCHEDULED FOR REUSE SHALL BE CLEANED, RESTORED <br />AND/OR REFINISHED TO LIKE NEW CONDITION, UNLESS NOTED OTHERWISE. <br />DO NOT REMOVE ANY EXISTING STRUCTURAL SUPPORT MEMBERS SUCH AS <br />COLUMNS, BEAMS, JOISTS, LOAD-BEARING PARTITIONS ETC, UNTIL ADEQUATE <br />PERMANENT OR TEMPORARY SUPPORT IS IN PLACE. ALL EXISTING <br />STRUCTURAL MEMBERS SHALL BE ADEQUATELY PROTECTED, COORDINATE <br />WITH STRUCTURAL ENGINEER. <br />SEE STRUCTURAL, DESIGN-BUILD MECHANICAL AND DESIGN-BUILD <br />ELECTRICAL DRAWINGS FOR RELATED DEMOLITION AND PREP WORK. <br />WALL AND CEILING MOUNTED ITEMS SHOWN DASHED, SUCH AS WALL <br />CABINETS, SHELVING, PROJECTION SCREENS ETC, SHALL BE REMOVED, <br />UNLESS NOTED OTHERWISE. <br />WITHIN ALL EXISTING ROOMS/SPACES RECEIVING SCHEDULED FLOOR, OR <br />WALL, OR CEILING FINISHES, REMOVE ALL EXISTING FLOOR, OR WALL, OR <br />CEILING FINISHES DOWN TO THE SUBSTRATE. INCLUDE THE REMOVAL OF ALL <br />ITEMS LOCATED WITHIN THE EXISTING FINISH REMOVALS U.N.O. PATCH AND <br />PREP ALL SUBSTRATES TO RECEIVE SCHEDULED FINISHES. FOR ADDITIONAL <br />INFORMATION, SEE KEYNOTED ITEMS, FINISH PLANS AND/OR SCHEDULES, <br />STRUCTURAL, MECHANICAL AND ELECTRICAL. <br />Revised 08-23-2016 <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br />8. <br />9. <br />10. <br />11. <br />12. <br />13. <br />A <br />DEMOLITION SYMBOLS LEGEND <br />PARTITION OR <br />WALL TO BE <br />DEMOLISHED <br />PARTITION OR <br />WALL TO REMAIN <br />DOOR, FRAME AND <br />HARDWARE TO BE <br />DEMOLISHED <br />DOOR, FRAME AND <br />HARDWARE TO <br />REMAIN <br />EXISTING <br />GRIDLINE <br />NEW GRIDLINE <br />NOTE: NOT ALL SYMBOLS MAY BE USED ON EACH PLAN <br />Revised 08-23-2016 <br />A <br />DE01 KEYNOTE <br />ALL DASHED LINES INDICATE AN ITEM <br />TO BE REMOVED, UNLESS NOTED OTHERWISE <br />101 <br />PR1 <br />101B <br />101A <br />8'-0" <br />M100 <br />OFFICE <br />100'-0" <br />FLOOR PLAN SYMBOLS LEGEND <br />WALL <br />EXISTING <br />WALL TO <br />REMAIN <br />EQUIPMENT <br />NUMBER <br />WORKING POINT <br />INTERIOR SECTION <br />REFERENCE TAG <br />EXTERIOR <br />SECTION <br />REFERENCE TAG <br />EXTERIOR <br />ELEVATION <br />REFERENCE TAG <br />INTERIOR <br />ELEVATION <br />REFERENCE TAG <br />PLAN <br />DETAIL <br />REFERENCE <br />TAG <br />KEYNOTE <br />GROMMET <br />REVISION <br />TAG <br />CENTERLINE <br />NEW GRIDLINE <br />REVISION <br />CLOUD <br />FLOOR <br />ELEVATION <br />ROOM NAME <br />AND NUMBER <br />EXTENDED <br />DIMENSION <br />LINE, NOMINAL <br />DIMENSION LINE <br />NOMINAL <br />INTERIOR <br />BORROWED <br />LIGHT <br />EXISTING DOOR <br />AND FRAME TO <br />REMAIN <br />DOOR <br />WALL TAGA3 <br />D <br />A <br />A <br />5101A <br />6051A 2A <br />620 <br />1A <br />500 <br />1A <br />500 <br />1A <br />8'-0" <br />FL01 <br />CL <br />EXISTING <br />GRIDLINE <br />Revised 08-23-2016 <br />FLOOR AND ENLARGED PLAN KEYED NOTES <br />NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN OR BID PACK <br />FL01 ACCESSIBLE FUME HOOD, SINK, OR WORKSTATION. <br />FL02 SLOTTED METAL CHANNEL FRAMING, SEE REFLECTED CEILING PLANS FOR <br />LOCATIONS. INCLUDE WEIGHT CAPACITY PER LINEAR FOOT IN SUBMITTAL <br />FL03 LASER IN USE SIGN AND LIGHT, SEE ELECTRICAL <br />FL04 SNORKEL EXHAUST, SEE MECHANICAL <br />FL05 NOT USED <br />FL08 FIRE DEPARTMENT CONNECTION, SEE DESIGN-BUILD FIRE SUPPRESSION <br />FL06 2" CONSTRUCTION EXPANSION JOINT <br />FL07 PROVIDE RECESSED SHELVING, SEE ELEVATION FOR MORE <br />INFORMATION. <br />FL09 BRANDING / GRAPHICS BY OWNER <br />9'-0" AFF <br />ACT <br />REFLECTED CEILING PLAN SYMBOLS LEGEND <br />GPBD <br />CEILING / <br />SOFFIT <br />ACT CEILING <br />SYSTEM <br />EXISTING ACT <br />CEILING <br />SYSTEM <br />ACCESS PANEL <br />CEILING <br />ELEVATION <br />AND FINISH <br />MECHANICAL <br />SUPPLY GRILLE <br />MECHANICAL <br />RETURN GRILLE <br />RECESSED <br />LIGHT <br />FIXTURE <br />PENDANT STRIP <br />LIGHT FIXTURE <br />PENDANT STRIP <br />LIGHT FIXTURE <br />1' X 4' <br />LIGHT <br />FIXTURE <br />2' X 2' <br />LIGHT <br />FIXTURE <br />2' X 4' <br />LIGHT <br />FIXTURE <br />NOTE: NOT ALL SYMBOLS MAY BE USED ON EACH PLAN <br />Revised 11-17-2016 <br />SYMBOLS LEGEND - ROOF PLAN <br />KEYNOTE <br />NOTE: NOT ALL SYMBOLS MAY BE USED ON EACH PLAN <br />PRIMARY AND OVERFLOW <br />ROOF DRAINS <br />+4" INSULATION THICKNESS <br />FLAT STRUCTURE WITH TAPERED <br />INSULATION (1/4" PER FOOT SLOPE <br />UNLESS NOTED OTHERWISE) <br />ROOF PAVERSRP01 <br />CONSTRUCTION LIMITS <br />CRICKET AT EQUIPMENT <br />CRICKET BETWEEN <br />ROOF DRAINS <br />EQUIPMENT PLAN GENERAL NOTES <br />EQUIPMENT SHOWN IS OWNER PROVIDED AND OWNER INSTALLED, FOR <br />REFENCE ONLY, UNLESS OTHERWISE NOTED <br />SEE DESIGN-BUILD MECHANICAL AND DESIGN-BUILD ELECTRICAL FOR <br />EQUIPMENT RELATED SERVICES <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br />8. <br />9. <br />10. <br />Revised <br />08-23-2016 <br />FINISH PLAN GENERAL NOTES <br />Revised 08-23-2016 <br />ALL LOUVERS, VENTS, GRILLES AND OTHER MISC MECHANICAL AND <br />ELECTRICAL DEVICES SHALL BE PAINTED TO MATCH SURFACE WHICH THEY <br />APPEAR, UNLESS OTHERWISE NOTED. <br />HM FRAMES TO BE PNT2, UNLESS NOTED OTHERWISE. <br />EXISTING WALLS TO RECEIVE SCHEDULED FINISHES SHALL HAVE EXISTING <br />FINISHES REMOVED AND SURFACES PREPARED TO RECEIVE FINISHES. <br />ALL FLOOR FINISHES SHALL CHANGE AT CENTERLINE OF DOOR, UNLESS NOTED <br />OTHERWISE. <br />CONTRACTOR IS RESPONSIBLE FOR MAKING SMOOTH, FLAT JOINTS BETWEEN <br />TRANSITIONS OF DIFFERENT FLOORING MATERIALS. FEATHER AS NEEDED <br />UNDER FLOORING TO CREATE FLUSH TRANSITION. <br />REFER TO SCHEDULE OF INTERIOR MATERIALS FOR FLOORING TRANSITION <br />TYPES. <br />REFER TO SCHEDULE OF INTERIOR MATERIALS FOR CORNER GUARD HEIGHTS. <br />1. <br />2. <br />3. <br />6. <br />13. <br />7. <br />14. <br />8. <br />16. <br />PAINT AND WOOD STAIN DRAW DOWNS MUST BE SUBMITTED AND APPROVED <br />BY INTERIOR DESIGNER. <br />9. <br />ALL WINDOW STOOLS TO BE SSM1, UNLESS NOTED OTHERWISE. 10. <br />NO RB AT MASONRY WALLS - TYPICAL, UNLESS NOTED OTHERWISE. 11. <br />NO RB AT STONE WALLS - TYPICAL.12. <br />15. <br />REFER TO ELEV/DETAILS FOR ADDITIONAL CASEWORK AND FINISH NOTES.5. <br />ALL COUNTERTOPS AND CASEWORK TO BE LAB CASEWORK, UNLESS NOTED <br />OTHERWISE. REFER TO SHEET 600 AND SPEC FOR MORE INFORMATION. <br />17. <br />WHEN MORE THAN ONE FINISH IS LISTED IN A ROOM FINISH TAG THE FIRST <br />FINISH LISTED IS THE PRIMARY FINISH. OTHER FINISHES LISTED ARE <br />SPECIFICALLY CALLED OUT AND ARE SHOWN IN ELEVATION. <br />4. <br />INSTALL WOOD AND GRAPHIC FILM WITH GRAIN VERTICAL, UNLESS NOTED <br />OTHERWISE. <br />REFER TO RCP PLANS AND NOTES FOR ALL CEILING FINISHES. <br />MAINTAIN RED BRICK MASONRY IN INTERIOR LOCATIONS WHERE POSSIBLE. <br />18.WHERE CASEWORK IS OPEN BELOW CONTINUE SCHEDULE FLOOR AND BASE. <br />REFLECTED CEILING PLAN GENERAL NOTES <br />GENERAL CONTRACTOR TO COORDINATE ALL CEILING MOUNTED EQUIPMENT <br />SUPPORT REQUIREMENTS, LOCATIONS, DIMENSIONS, ETC WITH EQUIPMENT <br />SUPPLIER AND OWNER, PRIOR TO INSTALLATION. <br />ALL CEILING MOUNTED ITEMS SUCH AS LIGHT FIXTURES, GRILLES, DIFFUSERS, <br />SPEAKERS, EXIT LIGHTS, ETC SHALL BE LOCATED IN THE CENTER OF ACT/ACB <br />PANELS, GPBD SOFFITS AND/OR PLASTER SOFFIT BAYS, UNLESS NOTED <br />OTHERWISE. COORDINATE WITH MECHANICAL AND ELECTRICAL DRAWINGS. <br />FINISHED GPBD SOFFITS SHALL EXTEND 1" BEYOND FACE AND EXPOSED ENDS <br />OF WALL CABINETS, FULL-HEIGHT CABINETS, ETC UNLESS NOTED OTHERWISE. <br />COORDINATE CABINET DIMENSIONS WITH SUPPLIER. GPBD FASCIA/SOFFIT <br />DETAILS ARE REFERENCED FROM THE REFLECTED CEILING PLAN. <br />SEE DESIGN-BUILD MECHANICAL DRAWINGS FOR SPRINKLER HEAD TYPES AND <br />LOCATIONS. CENTER ALL HEADS IN ACT OR ACB UNLESS NOTED OTHERWISE. <br />AT REMODELING WORK IN EXISTING ACT SUSPENSION SYSTEM, REMOVE <br />EXISTING PANELS, CUT AS REQUIRED FOR CONSTRUCTION AND RE-INSTALL. <br />REPLACE ALL DAMAGED AND EXTREMELY SOILED PANELS WITH ACT TO MATCH <br />EXISTING. <br />ALL GPBD CEILINGS AND SOFFITS TO BE PNT3, UNLESS NOTED OTHERWISE. <br />Revised <br />08-23-2016 <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />FINISH PLAN KEYED NOTES <br />FN01 WALL FINISHES VARY, SEE ELEVATIONS FOR FURTHER INFORMATION. <br />FN02 NO WORK IN THIS AREA, EXISTING FINISHES TO REMAIN. <br />FN03 PATCH TO MATCH EXISTING FINISHES AS DISTURBED BY CONSTRUCTION. <br />FN04 PROVIDE WT2, FULL HEIGHT, FULL WIDTH OF EACH WINDOW. <br />FN05 APPLY GF1 TO INTERIOR SIDE OF GLAZING. FULL HEIGHT, FULL WIDTH OF <br />GLAZING. <br />FN06 BASE TO MATCH EXISTING BASE OF ROOM. <br />FN07 MATCH ADJACENT ROOM FINISHES. <br />FN08 REPLACE EXISTING WINDOW STOOL WITH EPOXY STOOL TO MATCH LAB <br />CASEWORK COUNTERTOP. <br />FN09 EXISTING DOOR PANEL AND FRAME TO BE PAINTED PNT1. <br />NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN OR BID PACK <br />FN10 EXISTING WINDOW TREATMENTS TO REMAIN. COORDINATE WITH OWNER. <br />REFLECTED CEILING PLAN KEYED NOTES <br />RC01 EXPOSED STRUCTURE AND MEP COMPONENTS, PNT3 <br />RC02 EXPOSED STRUCTURE. NO FINISH REQUIRED <br />RC03 METAL RECESS FOR RETRACTABLE ELECTRICAL CORD REEL, SEE <br />RC04 RETRACTABLE ELECTRICAL CORD REEL, SURFACE MOUNTED TO STRUCTURE <br />ABOVE, SEE ELECTRICAL <br />RC05 SLOTTED METAL CHANNEL FRAMING, VISIBLE IN ROOM, 2" CLEAR BELOW <br />CEILING, THROUGH CEILING TO STRUCTURE ABOVE - INCLUDE WEIGHT <br />CAPACITY PER LINEAR FOOT IN SUBMITTAL <br />RC06 BLACKOUT CURTAIN ON TRACK <br />RC07 SNORKEL EXHAUST DROP, SEE MECHANICAL <br />NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN OR BID PACK <br />/1H 640 <br />ROOF DEMOLITION AND PLAN KEYED NOTES <br />RP04 ROOF TYPE EPDM-1A, SEE ROOF TYPES. <br />RP05 ROOF TYPE EPDM-1B, SEE ROOF TYPES. <br />RP02 PROVIDE CONCRETE CURB AT PENETRATIONS THROUGH CONCRETE PLANK <br />RP06 SCREEN WALL ON STRUCTURAL STEEL <br />RP01 DEMOLISH ROOFING AND CONCRETE PLANK FOR DUCT PENETRATION OR AHU, <br />SEE MECHANICAL AND STRUCTURAL <br />RP03 PATCH AND REPAIR ROOF AT DUCT PENETRATION OR AHU, SEE MECHANICAL <br />NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN OR BID PACK <br />CG <br />FINISH SYMBOLS LEGEND & ABBREVIATIONS <br />MATERIAL <br />CHANGE <br />LOCATION <br />MATERIAL <br />INSTALL <br />DIRECTION <br />ACCENT WALL <br />FINISH <br />KEYNOTE <br />PNT <br />VCTCPT <br />FLOOR FINISH(ES) <br />BASE FINISH <br />WALL FINISH(ES) <br />WALL <br />PROTECTION <br />CORNER GUARD <br />ROOM NUMBER <br />FN01 <br />Revised 08-23-2016