PROPOSED BUILDING ADDITION 'B'PROPOSED BUILDINGADDITION 'F'PROPOSED BUILDING ADDITION 'G'SOUTH PARKING(14 BUS STALLS)45°0'0REFER TO ARCHITECTURAL PLANSFOR DIMENSIONS AND LAYOUTREFER TO ARCHITECTURAL PLANSFOR DIMENSIONS AND LAYOUTREFER TO ARCHITECTURAL PLANSFOR DIMENSIONS AND LAYOUTMATCH EXISTING FENCEHEIGHT AND LAYOUT - NOMAINTENANCE STRIPMATCH EXISTING FENCE HEIGHTAND LAYOUT INCLUDING GATESIZES AND LOCATIONSMATCH EXISTING FENCEHEIGHT AND LAYOUT - NOMAINTENANCE STRIPMATCH EXISTING FENCEHEIGHT AND LAYOUT - NOMAINTENANCE STRIPTO12' WALK1C2.131C2.131C2.131C2.131C2.131C2.13TRANSFORMER - REFER TOELECTRICAL PLANSFUEL OIL TANK - REFER TOMECHANICAL PLANS1C2.131C2.131C2.13C2.1318C2.11244C2.135C2.135C2.135C2.136C2.136C2.136C2.137C2.137C2.1311C2.1311C2.1311C2.1311C2.1311C2.1311C2.1311C2.1311C2.1311C2.1311C2.1311C2.1311C2.13C2.1318C2.1124C2.1318C2.1124C2.1320C2.1318C2.123C2.1221C2.12C2.1320C2.13181C2.12C2.123C2.1221C2.12C2.1320C2.1318C2.123C2.1221C2.12C2.1320C2.1318C2.123C2.12221C2.135C2.135C2.131C2.1324C2.1118C2.13TIE INTO EXISTING RETAINING WALL. DISMANTLEEXISTING RETAINING WALL SYSTEM AS REQUIRED.TIE INTO EXISTING RETAINING WALL. DISMANTLEEXISTING RETAINING WALL SYSTEM AS REQUIRED.TIE INTO EXISTING RETAINING WALL AND EXISTINGFENCE. DISMANTLE EXISTING RETAINING WALL SYSTEMAS REQUIRED. MATCH EXISTING FENCE HEIGHT ANDCONCRETE MAINTENANCE STRIP / MOUNTING TO WALL.18C2.1318C2.136C2.136C2.136C2.136C2.13PLACE POST AS CLOSE ASPOSSIBLE TO BUILDINGPLACE POST MIN. 12"INSIDE BITUMINOUS LIMITS18C2.133' WIDE SINGLE SWING GAWITH LATCHING DEVICE5C2.135C2.13TIE INTO EXISTING RETAINING WALL AND EXISTINGFENCE. DISMANTLE EXISTING RETAINING WALL SYSTEMAS REQUIRED. MATCH EXISTING FENCE HEIGHT ANDCONCRETE MAINTENANCE STRIP / MOUNTING TO WALL.1C2.13C2.131C2.13C2.1318C2.11246C2.139C2.1314C2.13NOTES:LEGENDREFERENCE KEY TO SITE DETAILS DETAIL I.D NUMBER (TOP) DETAIL SHEET NUMBER (BOTTOM)PROPOSED CONCRETE WALKPROPOSED CONCRETE SLABPROPOSED MEDIUM DUTY BITUMINOUS PAVEMENTPROPOSED HEAVY DUTY BITUMINOUS PAVEMENTPROPOSED LAKE VALENTINE ROAD BITUMINOUS PAVEMENTPROPOSED RETAINING WALLPROPOSED REINFORCED SOIL SLOPE (RSS)PROPOSED CHAIN LINK / DECORATIVE METAL FENCING WITH MAINTENANCE STRIPPROPOSED TRAFFIC CONTROL SIGNPAINTED ACCESSIBLE SYMBOLPROPOSED MANHOLE (MH)PROPOSED CATCH BASIN (CB)PROPOSED FLARED END SECTION (FES)PROPOSED HYDRANT (HYD)PROPOSED GATE VALVE (GV)PROPOSED BUILDING STOOP - REFER TO ARCHITECTURAL PLANSPROPERTY LINE1C2.116C2.137C2.1310C2.1311C2.1312C2.1324C2.111C2.122C2.123C2.1218C2.1319C2.1320C2.1313C2.1314C2.1315C2.1316C2.1317C2.1315C2.1119C2.1120C2.1122C2.1123C2.1117C2.1116C2.11LANDSCAPE ARCHITECTURE SITE PLANNING CIVIL ENGINEERINGANDERSON - JOHNSONASSOCIATES,INC.7575 GOLDEN VALLEY ROAD SUITE 200 MINNEAPOLIS. MN 55427FAX (763) 544-0531 PH (763) 544-7129DateRegistration NumberCheckDrawnDate:CommI hereby certify that this plan, specification or report was prepared byme or under my direct supervision and that I am a duly Licensedunder the laws of the State ofRevisionsDescription Date NumScale:North501 South Eighth StreetMinneapolis, MN 55404krausanderson.com | 612 332 7281MOUNDS VIEWHIGH SCHOOL 2019IMPROVEMENTS1900 Lake Valentine RoadARDEN HILLS, MINNESOTA 551124570 VICTORIA STREET NSHOREVIEW, MINNESOTA 55126ISD #621: MOUNDS VIEWPUBLIC SCHOOLSPROFESSIONAL ENGINEERMINNESOTAC1.231" = 30'DARMET02/06/20191722704018002/06/2019DAVID A. REYSOUTHPLANFINISHINGAddendum #2 02/22/201911. REFER TO SHEET C1.34, GRADING AND DRAINAGE PLAN FIELDS, FOR GENERAL NOTES.2. CHECK ALL PLAN AND DETAIL DIMENSIONS AND VERIFY SAME BEFORE FIELD LAYOUT.3. SIGNAGE SHALL GENERALLY BE INSTALLED 18" BEHIND THE BACK OF CURB.4. ALL DISTURBED AREAS OUTSIDE THE BUILDING PAD WHICH ARE NOT DESIGNATED TO BEPAVED SHALL RECEIVE AT LEAST 6" OF TOPSOIL AND SHALL BE SODDED OR SEEDED.5. WHERE NEW SOD MEETS EXISTING TURF, EXISTING TURF EDGE SHALL BE CUT TO ALLOW FORA CONSISTENT, UNIFORM STRAIGHT EDGE. JAGGED OR UNEVEN EDGES WILL NOT BEACCEPTABLE. REMOVE TOPSOIL AT JOINT BETWEEN EXISTING AND NEW AS REQUIRED TOALLOW NEW SOD SURFACE TO BE FLUSH WITH EXISTING.6. FAILURE OF TURF DEVELOPMENT: IN THE EVENT THE CONTRACTOR FAILS TO PROVIDE ANACCEPTABLE TURF, THE CONTRACTOR SHALL RE-SOD OR RE-SEED ALL APPLICABLE AREAS,AT NO ADDITIONAL COST TO THE OWNER, TO THE SATISFACTION OF THE ENGINEER.7. ALL DIMENSIONS ARE TO FACE OF CURB, CENTERLINE OF FENCE, OR PROPERTY LINE UNLESSOTHERWISE NOTED.Addendum #3 02/26/2019 2