My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
02-05-2020 PC
ArdenHills
>
Administration
>
Commissions, Committees, and Boards
>
Planning Commission
>
Planning Commission Packets
>
2020
>
02-05-2020 PC
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/3/2020 9:29:26 AM
Creation date
2/3/2020 9:28:04 AM
Metadata
Fields
Template:
General
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
72
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
/EEKsd/KEtzEEEEEEEEEEDGE OF WOODSEDGE OF WOODS8" Ash10" Poplar10" Poplar10" Poplar10" Poplar6" Poplar10" Poplar12" Poplar10" Poplar12" Poplar8" Poplar10" Poplar8" Ash12" Box12" Box8" Poplar7" Poplar7" Poplar8" Poplar9" Poplar12" Poplar8" Poplar8" Poplar8" Poplar8" Poplar7" Poplar6" Poplar6" PoplarCDDD.EDFDGD5D6DT-01T-02T-03T-04T-05T-06T-07T-08T-09T-10T-11T-12T-13T-14T-15T-16T-17T-18T-19T-20T-21T-22T-23T-24T-25T-26T-27LIMIT OF WORKLIMIT OF WORKT-28T-29T-304' CLEAR235" CAL. OF TOTAL TREES REMOVED-131" CAL OF ASH REMOVEDSYMBOL SPECIES CAL/SIZETYPESTATUSPINE8"SOFTWOOD DEMOPOPLAR10"SOFTWOOD DEMOPOPLAR12"SOFTWOOD DEMOASH4"HARDWOOD DEMOSPRUCE7"SOFTWOOD DEMOASH2"EVERGREEN DEMOASH8"HARDWOOD DEMOASH10"HARDWOOD DEMOASH9"HARDWOOD DEMOASH10"HARDWOOD DEMOASH12"HARDWOOD DEMOASH10"SOFTWOOD DEMOPOPLAR8"SOFTWOOD DEMOPOPLAR8"SOFTWOOD DEMOPOPLAR8"SOFTWOOD DEMOASH7"HARDWOOD DEMOASH8"HARDWOOD DEMOASH8"HARDWOOD DEMOBOX2"SOFTWOOD DEMOPOPLAR10"HARDWOOD DEMOASH14"HARDWOOD DEMOASH14"HARDWOOD DEMOASH8"HARDWOOD DEMOASH7"HARDWOOD DEMOSPRUCE8"SOFTWOOD DEMOSPRUCE6"SOFTWOOD DEMOSPRUCE14"SOFTWOOD DEMOCOTTONWOOD3"HARDWOOD DEMOCOTTONWOOD24"HARDWOOD DEMOCOTTONWOOD4"HARDWOOD DEMOT-01T-02T-03T-04T-05T-06T-07T-08T-09T-10T-11T-12T-13T-14T-15T-16T-17T-18T-19T-20T-21T-22T-23T-24T-25T-26T-27TREE PRESERVATION SCHEDULET-28T-29T-30L003TREE PROTECTIONPLANProject No.Revisions1220 Marshall Street NEMinneapolisMinnesota 55413-1036612.677.7100612.677.7499 faxwww.rsparch.comRSP ArchitectsCertificationProject ForI hereby certify that this plan, specification or reportwas prepared by me or under my direct supervision andthat I am a duly licensed Architect under the laws of theState of Minnesota.DateRegistration NumberSignatureDrawn ByChecked ByDateNOTICE: The designs shown and described hereinincluding all technical drawings, graphics, and modelsthereof, are proprietary and cannot be copied,duplicated or commercially exploited, in whole or inpart, without express written permission of RSPArchitects. These are available for limited review andevaluation by clients, consultants, contractors,government agencies, vendors and office personnelonly in accordance with this Notice.© Copyright RSP Architects 2019. All rights reserved.Consultants3/21/2019 5:30:14 PMC:\Revit Projects\A17_02-579_HCR Molding_JLarson.rvt>'ϭϬZdK</d/KEͲW,^ϭKEVIN HENNCHUCK EVENSNo. Date Description401 North 2nd Avenue, Suite 410Minneapolis, MN 55401 p: 612.332.7522CITY REVIEW12/02/196132.012.18EXISTING CONDITIONS &SITE REMOVAL NOTESSITE REMOVAL NOTES1. EXISTING SITE INFORMATION WAS PROVIDED BY OTHERS. ACTUAL FIELD CONDITIONS MAY VARY. FIELD VERIFYUTILITY LOCATIONS AND ELEVATIONS PRIOR TO CONSTRUCTION.2. THE LOCATIONS OF EXISTING UTILITIES SHOWN ON THIS PLAN HAVE BEEN DETERMINED FROM THE BESTINFORMATION AVAILABLE AND ARE GIVEN FOR THE CONVENIENCE OF THE CONTRACTOR. THE LANDSCAPEARCHITECT ASSUMES NO RESPONSIBILITY FOR THEIR ACCURACY. PRIOR TO THE START OF DEMOLITIONACTIVITY, THE CONTRACTOR SHALL NOTIFY THE UTILITY COMPANIES FOR ONSITE LOCATIONS OF EXISTINGUTILITIES. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT EXISTINGUTILITIES OR STRUCTURES LOCATED AT THE WORK SITE.3. CONTRACTOR TO VERIFY THE LOCATION OF UNDERGROUND UTILITIES PRIOR TO BEGINNING ANY CONSTRUCTIONBY CALLING GOPHER STATE ONE-CALL AT 651-454-0002 (METRO) OR 1-800-252-1166 (OUT-STATE).4. THE CONTRACTOR SHALL COORDINATE WITH RESPECTIVE UTILITY COMPANIES PRIOR TO THE REMOVAL AND/ORRELOCATION OF UTILITIES. THE CONTRACTOR SHALL COORDINATE WITH THE UTILITY COMPANY CONCERNINGPORTIONS OF WORK WHICH MAY BE PERFORMED BY UTILITY COMPANY'S FORCES AND FEES WHICH ARE TO BEPAID TO THE UTILITY COMPANY FOR THEIR SERVICES. THE CONTRACTOR IS RESPONSIBLE FOR PAYING FEES ANDCHARGES.5. ALWAYS VERIFY BENCHMARK ELEVATIONS BETWEEN TWO BENCHMARKS.6. REMOVAL ITEMS BECOME THE PROPERTY OF THE CONTRACTOR UNLESS SPECIFIED OTHERWISE. THECONTRACTOR IS RESPONSIBLE FOR REMOVING DEBRIS FROM THE SITE AND DISPOSING THE DEBRIS IN A LAWFULMANNER PER LOCAL GOVERNING AGENCIES. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING PERMITSREQUIRED FOR DEMOLITION AND DISPOSAL. FACILITIES TO BE REMOVED SHALL BE UNDERCUT TO SUITABLEMATERIAL AND BROUGHT TO GRADE WITH SUITABLE COMPACTED FILL MATERIAL PER THE SPECIFICATIONS.7. PRIOR TO DEMOLITION, EROSION CONTROL DEVICES ARE TO BE INSTALLED WHERE NECESSARY AND OBTAIN ANNPDES STORM WATER PERMIT. REFER TO CIVIL FOR EROSION CONTROL.8. DAMAGE TO REMAINING EXISTING CONDITIONS WILL BE REPLACED AT CONTRACTOR'S EXPENSE AND SHALL BEEQUAL TO OR EXCEED THE QUALITY OF CONSTRUCTION PRIOR TO DAMAGE.9. CONCRETE PAVEMENT, SIDEWALKS, CURB AND GUTTER, AND OTHER POURED CONCRETE ITEMS ARE TO BEREMOVED TO AN EXISTING EXPANSION OR CONTRACTION JOINT.10. CONTRACTOR SHALL LIMIT SAW-CUT AND PAVEMENT REMOVAL TO ONLY THOSE AREAS WHERE IT IS REQUIREDAS SHOWN ON THESE CONSTRUCTION PLANS. IF DAMAGE IS INCURRED ON THE SURROUNDING PAVEMENT, ETC.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ITS REMOVAL AND REPAIR AT NO ADDITIONAL COST TO THEOWNER. BITUMINOUS PAVEMENT REMOVALS ARE TO BE MADE WITH A VERTICAL SAW CUT OR TO A NEAT MILLEDEDGE.11. CONTRACTOR SHALL PRESERVE VEGETATION NOT TO BE REMOVED BY CONSTRUCTION. CONTRACTOR SHALL BERESPONSIBLE FOR RE-SEEDING OR SODDING AREAS DISTURBED BY CONSTRUCTION.12. LOCATION AND ELEVATIONS OF IMPROVEMENTS TO BE MET (OR AVOIDED) SHALL BE CONFIRMED BY THECONTRACTOR THROUGH FIELD EXPLORATIONS PRIOR TO CONSTRUCTION. CONTRACTOR SHALL REPORT TO THELANDSCAPE ARCHITECT DISCREPANCIES BETWEEN THEIR MEASUREMENTS AND THESE PLANS. CONTRACTORSHALL ALSO MAKE EXPLORATION EXCAVATIONS AND LOCATE EXISTING UNDERGROUND UTILITIES SUFFICIENTLYAHEAD OF CONSTRUCTION TO PERMIT REVISIONS TO PLANS IF REVISIONS ARE NECESSARY BECAUSE OF ACTUALLOCATION OF EXISTING FACILITIES. CONTRACTOR IS REQUIRED TO TAKE PRECAUTIONARY MEASURES TOPROTECT THE UTILITY LINES SHOWN AND OTHER EXISTING LINES NOT OF RECORD OR NOT SHOWN ON THESEPLANS.13. EXISTING UTILITIES TO REMAIN IN PLACE UNLESS SPECIFICALLY MARKED ON THIS SHEET.BUILDING 10NORTH0SCALE:1" = 10'10 2030CITY SUBMITTAL - 16 DECEMBER 2019(REVISION 1 - 10 JANUARY 2020)
The URL can be used to link to this page
Your browser does not support the video tag.