PROJECT SUMMARYNot to be reproduced in whole or part without the written consent of MuscoSports Lighting, LLC. ©1981, 2021 Musco Sports Lighting, LLC.ENGINEERED DESIGNBy: Joe Seda · File #209568B · 09-Feb-21Bethel University Royal Stadium FootballSaint Paul, MN USALighƟng System Pole / Fixture SummaryPole IDPole HeightMtg HeightFixture QtyLuminaire TypeLoadCircuitF1-F290'90'1TLC-LED-12001.17 kWA90'10TLC-LED-150014.30 kWA90'1TLC-LED-4000.40 kWA20'2TLC-BT-5751.15 kWAF3-F480'80'1TLC-LED-12001.17 kWA80'9TLC-LED-150012.87 kWA19'2TLC-BT-5751.15 kWA80'3TLC-LED-15004.29 kWB80'1TLC-LED-4000.40 kWA46073.80 kW Circuit SummaryCircuitDescriptionLoadFixture QtyAFootball65.22 kW54BSoccer 28.58 kW6 Fixture Type SummaryTypeSourceWattageLumensL90L80L70QuantityTLC-LED-1500LED 5700K - 75 CRI1430W160,000>120,000>120,000>120,00044TLC-LED-400LED 5700K - 75 CRI400W46,500>120,000>120,000>120,0004TLC-BT-575LED 5700K - 75 CRI575W52,000>120,000>120,000>120,0008TLC-LED-1200LED 5700K - 75 CRI1170W136,000>120,000>120,000>120,0004Light Level Summary Calculation Grid SummaryIlluminationGrid NameCalculation MetricAveMinMaxMax/MinAve/MinCircuitsFixture QtyFootballHorizontal Illuminance53.639671.741.37A54Home BleachersHorizontal14.76213.402.44A54Property LineHorizontal0.1100.370.00A,B60Property LineMax Candela (by Fixture)2709117.51094726273.161552.48A,B60Property LineMax Vertical Illuminance Metric0.3701.280.00A,B60Soccer 2Horizontal Illuminance9.8502688833.59B6SoccerHorizontal Illuminance53.839661.691.38A54Track SpillHorizontal Illuminance0.0300.0741.34A54Track SpillMax Candela Metric95563082812591.3431.04A54Track SpillMax Vertical Illuminance Metric0.120.010.2641.3011.60A54TrackHorizontal Illuminance22.55499.184.51A54Visitor BleachersHorizontal11.77162.321.67A54 $WWDFKPHQW(