Laserfiche WebLink
ILLUMINATION SUMMARYNot to be reproduced in whole or part without the written consent of MuscoSports Lighting, LLC. ©1981, 2021 Musco Sports Lighting, LLC.ENGINEERED DESIGNBy: Joe Seda · File #209568B · 09-Feb-21OVERHEADPOWER LINESMULTI-PURPOSEFIELD(~195'x345')0141018201601411192019015101722210141017252001410171915014101818100141221261301410192515013915172001381522240137132325001481316130'58'130'152'F3F4SCALE IN FEET 1 : 500'50'100'EQUIPMENT LIST FOR AREAS SHOWNPole LuminairesQTYLOCATIONSIZEGRADEELEVATIONMOUNTINGHEIGHTLUMINAIRETYPEQTY /POLETHISGRIDOTHERGRIDS2F3-F480'.43'80.43'80.43'19.43'80.43'TLC-LED-1200TLC-LED-400TLC-BT-575TLC-LED-150011*29/3*000311292TOTALS32626 * This structure uƟlizes a back-to-back mounƟng conĮguraƟonPole locaƟon(s)dimensions are relaƟveto 0,0 reference point(s)Bethel University Royal Stadium FootballSaint Paul, MN USAGRID SUMMARYName: Soccer 2Size: 345' x 195'Spacing: 30.0' x 30.0'Height: 3.0' above gradeILLUMINATION SUMMARYMAINTAINED HORIZONTAL FOOTCANDLESEnƟre GridScan Average:9.85Maximum: 26Minimum: 0Avg / Min: 33028.69Max / Min:88833.59UG (adjacent pts): 1166.11CU: 0.79No. of Points: 84LUMINAIRE INFORMATIONApplied Circuits: BNo. of Luminaires: 6Total Load: 8.58 kWGuaranteed Performance:The ILLUMINATION describedabove is guaranteed per your MuscoWarranty document and includes a 0.95dirt depreciaƟon factor.Field Measurements:Individual Įeld measurements may vary fromcomputer-calculated predicƟons and should be takenin accordance with IESNA RP-6-15.Electrical System Requirements:Refer to AmperageDraw Chart and/or the"Musco Control System Summary"for electrical sizing.InstallaƟon Requirements:Results assume ± 3%nominal voltage at line side of the driver and structureslocated within 3 feet (1m) of design locaƟons.