Laserfiche WebLink
FLOOR PLAN GENERAL NOTESA.1ALL DIMENSIONS SHOWN ARE FRAMING DIMENSIONS (FACE OF STUD/JAMB) UNLESS OTHERWISE NOTED. A.2FASTENERS, ANCHORS, CLIPS, STRAPS, ETC WHICH ARE IN CONTACT WITH PRESERVATIVE AND/OR FIRE TREATED WOOD SHALL BE OF G-185 HOT DIPPED ZINC-COATED GALVANIZED STEEL, STAINLESS STEEL, OR AN APPROVED EQUAL. A.3REFER TO CIVIL AND LANDSCAPE FOR LOCATIONS OF WALKS, BOLLARDS, LANDSCAPING AREAS, FLAG POLE, AND OTHER SITE ITEMS.A.4REFER TO INTERIOR ELEVATIONS FOR LOCATIONS AND TYPES OF CORNER GUARDS.A.5CONTRACTOR TO COORDINATE LOCATION OF POLE MOUNTED EXTERIOR CAMERA WITH STRONG SYSTEMS AND INSTALL UNDERGROUND CONDUIT AS REQUIRED. RE: ELECTRICAL.A.6REFER TO ACCESSIBILITY PLAN AND FURNITURE DRAWINGS FOR SEATING LAYOUT & SPECIFICATIONS. CONTACT: OWNER. A.7REFER TO ACCESSIBILITY PLAN AND OWNER DRAWINGS FOR CONDIMENT COUNTERS AND TRASH RECEPTACLES. A.8REFER TO IT WALLBOARD USER GUIDE FOR WALLBOARD INSTALLATION, IF APPLICABLE.WALL INSULATION NOTESWALL NOTESINTERIOR WALL FRAMING NOTESEXTERIOR WALL FRAMING NOTESD.1SEE STRUCTURAL DRAWINGS FOR STUD DIMENSIONS AND SPACING.D.2AT WOOD STUD EXTERIOR WALLS, USE TREATED SILL PLATES. EXTERIOR SHEATHING NOTESE.1REFER TO STRUCTURAL FOR EXTERIOR SHEATHING TYPES.BLOCKING NOTESF.1WALL BLOCKING SHALL BE THE GENERAL CONTRACTOR’S RESPONSIBILITY. BLOCKING SHALL INCLUDE, BUT IS NOT LIMITED TO: AREAS INDICATED ON INTERIOR ELEVATIONS FOR GRAB BARS, SHELVING BRACKETS, MONITORS, FIXTURES, ETC, AS WELL AS BLOCKING FOR WINDOWS, CANOPIES ROOF FRAMING, ROOF TOP UNITS, ETC. INTERIOR WALL FINISH & INTERIOR SHEATHING NOTESAT MATERIALS LABELED "INTERIOR SHEATHING”ON WALL TYPE DRAWINGS AND DETAILS, SHEATHING SHALL BE AS FOLLOWS UNLESS NOTED OTHERWISE. REFER TO FINISH PLAN AND INTERIOR ELEVATIONS FOR FINISH MATERIAL ON INTERIOR SHEATHING. DO NOT USE WOOD SHEATHING WITHIN 18" OF HOODS. G.1WHERE SHEATHING IS EXPOSED: 1/2" GYPSUM BOARD. PAINTED PER INTERIOR ELEVATIONS AND FINISH PLAN. G.2BETWEEN WALL TILE AND STUDS: 1/2" CEMENTITIOUS BACKER BOARD.G.3BETWEEN FRP PANELS AND WOOD STUDS AT BACK OF HOUSE: COMPOSEAL GOLD 40 MIL WATERPROOF MEMBRANE AND 1/2" CEMENTITIOUS BOARD TO 1'-0" ABOVE SLAB. 1/2”CDX PLYWOOD SUBSTRATE ABOVE CEMENTIOUS BOARD TO 1'-0" ABOVE CEILING. RE: TYPICAL WALL BASE DETAIL. G.4BETWEEN FRP PANELS AND METAL STUDS: COMPOSEAL GOLD 40 MIL WATERPROOF MEMBRANE AND 1/2" CEMENTIOUS BOARD TO 1'-0" ABOVE SLAB. 1/2" CEMENTITIOUS BOARD TO 4" ABOVE CEILING, EXCEPT AT AREAS WHERE DRAFTSTOPPING IS REQUIRED. REFER TO DRAFTSTOPPING DETAILS FOR THOSE AREAS. G.5BETWEEN FRP PANELS AND WOOD STUDS AT PLAY AREA: 1/2" GYPSUM BOARD.G.6BETWEEN STAINLESS STEEL PANELS AND METAL STUDS: 1/2" CEMENTIOUS BOARD.G.7BETWEEN STAINLESS STEEL PANELS AND WOOD STUDS: 1/2" CEMENTIOUS BOARD.G.8BETWEEN WALLCOVERING AND STUDS: 1/2" GYPSUM BOARD. G.9BETWEEN WOOD WAINSCOT AND WOOD STUDS: 1/2" PLYWOOD.G.10BETWEEN WOOD WAINSCOT AND METAL STUDS: 1/2”PLYWOOD. G.11BETWEEN FREEZER/COOLER WALLS AND WOOD STUD WALLS: 1 FT TALL CEMENT BOARD BASE WITH 1/2" GYPSUM BOARD (LEVEL 1 FINISH) TO 6”ABOVE FINISH CEILING. EXTEND 40 MIL COMPOSEAL GOLD WATERPROOF MEMBRANE FROM FLOOR AS INDICATED ON FINISH PLAN UP WALL AS INDICATED ON FREEZER AND COOLER SCREED DETAILS. G.12BEHIND WOOD BOARD FINISH AT ICON WALL: 3/4" PLYWOOD. G.13BEHIND WOOD BOARD FINISH AT OTHER LOCATIONS: 1/2" PLYWOOD.INTERIOR BASE FINISH & SHEATHING NOTESAT MATERIALS LABELED "INTERIOR SHEATHING”ON WALL TYPE DRAWINGS AND DETAILS, MATERIALS SHALL BE AS FOLLOWS UNLESS NOTED OTHERWISE. REFER TO FINISH PLAN AND INTERIOR ELEVATIONS FOR BASE FINISH MATERIAL. H.1BETWEEN TILE BASE AT KITCHEN AND STUDS: 1/2" CEMENTITIOUS BACKER BOARD TO MINIMUM 1'-0" ABOVE SLAB.H.2BETWEEN TILE BASE AT NON-KITCHEN AREAS AND STUD WALLS: 1/2" CEMENT BACKER BOARD TO MINIMUM 5" ABOVE SLAB. H.3BETWEEN VINYL BASE AND WOOD STUD WALLS: 1/2" GYPSUM BOARD. B.1WHERE EXTERIOR METAL STUD WALL TYPE REQUIRES BATT INSULATION, USE R-19 FOIL FACED BATT INSULATION. B.2WHERE EXTERIOR WOOD STUD WALL REQUIRES BATT INSULATION, USE R-19 KRAFT FACED FIBERGLASS BATT INSULATION WITH FLAME SPREAD INDEX OF NOT MORE THAN 25 AND SMOKE DEVELOPED INDEX OF NOT MORE THAN 450. B.3WHERE EXTERIOR STUD WALLS REQUIRE BATT INSULATION, EXTEND INSULATION UP 12" ABOVE ROOFTOP RIGID INSULATION. B.4AT INTERIOR METAL STUD WALLS WHERE INSULATION IS SCHEDULED, USE 3-1/2" FOIL FACED BATT INSULATION. B.5AT INTERIOR WOOD STUD WALLS WHERE INSULATION IS SCHEDULED, USE 3-1/2" BATT INSULATION WITH MAXIMUM FLAME SPREAD INDEX OF 25. B6.NOT USEDC.1UNLESS NOTED OTHERWISE, EXTEND FRAMING TO 6" ABOVE ADJACENT CEILINGC.2AT DRAFT STOPPING PARTITION INTERIOR WALLS, EXTEND FRAMING TO ROOF DECK AS REQUIRED TO ACCOMMODATE SMOKE BARRIER. C.3WHERE INTERIOR WALLS ARE NOT INSULATED AND NOT A DRAFT STOPPING PARTITION, FRAMING MAY STOP 6" ABOVE HIGHEST ABUTTING FINISH CEILING. C.4WHERE INTERIOR WALL FRAMING DOES NOT EXTEND TO STRUCTURE ABOVE, BRACE INTERIOR WALLS AS REQUIRED FOR COMPLIANCE WITH BUILDING CODE, REF BUILDING DATA ON COVER SHEET.C.5FRAMING AT NON-LOADBEARING INTERIOR WALLS SHALL MEET REQUIREMENTS OF APPLICABLE BUILDING CODES AND LOCAL AMENDMENTS.FLOOR PLAN WALL & PARTITION LEGENDWOOD STUD WALLMETAL STUD WALLNOTE: SEE WALL & PARTITION TYPES AND SMOKE BARRIER INDICATED ON REFLECTED CEILING PLAN FOR ADDITIONAL INFORMATIONBATT INSULATIOND1A-301B1A-301B3A-301C1A-301A-621785A-6011432A-60110987A-602576A-611D3A-6035A-60212786141315A-62212A-6226A-6219A-6022A-62110111213A-62211A-60244A-62231E2A-604_____________________E1A-604_____________________A-6211A-623B3A-62210A3A-401A-701A3A2A-401A4A-401A1A-4016A-701A2A-701A4A-631522LW6W4W4W4W4SW6SW6W822LSW635'-5 1/2"33'-8 1/4"4'-11 1/2"11'-6 1/2"4'-3 3/4"W4W4W4WOMENSMENSRR VEST31CLOSET32304'-6 1/4"6'-0"14'-5"6'-0"4'-6 1/4"KK22LW6W63'-4"40'-1"3'-7 1/2"W618L3LKITCHENTEAM MEMBERROOM1'-7 21/32"41'-11"5'-4"8'-5 1/2"8'-5 1/2"18LW6W630'-7 1/2"7'-11"2 3/4"8'-5 3/4"8'-5 1/2"8'-5 1/2"W822LHOOD #15L1LSM6DRIVE THRU4L6 1/2"3'-4"8'-11 3/4"10'-1"4'-3 1/4"6"2'-4"HOOD #3SERVING10M84L9L2LHOOD #2SW6SW6PROVIDE MINIMUM 9" CLEAR FROM EDGE OF PANEL TO ADJACENT WALL SURFACE TO AVOID CONFLICT WITH LADDER 18LMAINTAIN 1" GAP -TYPICAL TRIMW6419'-6"64'-4"W6W6W6SM6SW6.1SM6SW6.17'-4 1/8"8'-2 3/8"4'-4"8'-10 3/8"5'-3 5/8"3'-4"2'-8 1/2"2'-5"25A02.0L24A02.0L22LSW615FCC17'-1 3/4"7'-9 1/2"W63'-4"1'-9 1/8"10'-7 3/4"7'-0 1/2"1'-9 3/4"7'-9"6'-0"20'-8"6'-0"23'-11"5L14'-4 3/4"6'-0"13'-3 1/2"SERVICEDTT CLOSETOFFICESTORAGE33SW6401211167'-8"4'-0"19'-5"9'-0"C1'-10"3'-10"13W6W6W614METAL INFILL4'-4 1/2"11'-4"METAL INFILL17'-3"8'-4 1/2"3'-3 1/2"3'-8 1/2"4'-4"SW647'-0 1/2"REFER TO A-105 FOR OMD CANOPY INFO4L22L22L22L22L22L20L1981922L22L19L9'-6 1/2"4'-8 1/2"4'-4 1/2"4'-0 1/2"17'-2"4L10'-5"6'-4 1/2"1'-10 3/4"4'-9 3/4"6'-0"4'-8"6'-0"4'-7 3/4"3'-4 1/2"2'-9"AA22LE20H21AO23AAAA3'-6 3/8"6'-0"6'-0"6'-0"3'-9 7/8"4'-10 1/8"6'-0"4'-4 5/8"40'-7"7'-3"2'-8"6'-4 1/2"5"23'-0 3/4"7'-0"VESTIBULEDINING1'-8"6'-0"4'-8"6'-0"4'-8"6'-0"1'-7 7/8"35'-9"50'-11 1/4"W6W6W6SW6SW6SW6.2SW6.2SW65'-2"120'-1"SW6.214'-11"8'-8 1/2"5'-7 3/4"1GC SHALL PROVIDE 5-1/2" HIGH CONCRETE MILLWORK CURBS. RE: OWNER SHOP DRAWINGS FOR EXACT LOCATIONS & DIMENSIONS.3FREEZER AND COOLER DOORS AND HARDWARE SUPPLIED BY FREEZER/ COOLER MANUFACTURER.2GC SHALL SECURE SAFE USING (4) HILTI-HAS-E 1/2" x 4-1/2" ANCHOR BOLTS WITH HILTI HVU ADHESIVE CAPSULE. AT EACH HOLE FASTEN THRU PHENOLIC BASE OF CABINET AND INTO CONCRETE CURB BELOW. VERIFY LOCATION WITH SAFE MANUFACTURER. 4DASHED LINE INDICATES SOFFIT OR BULKHEAD ABOVE, RE: REFLECTED CEILING PLAN.5RECESSED PIN AND SLEEVE BOX, RE: A4/A-620 & ELECTRICAL. 2'-1" ROUGH OPENING WIDTH AT HOOD #2. 11" ROUGH OPENING WIDTH AT HOOD #38STEEL WALL BY OWNER (TYP.) RE: OWNER FOR EXACT LOCATION.9 SAFE SCREEN BY OWNER.15NETWORK CABINET.18 ELECTRICAL PANEL. RE: ELECTRICAL.19 ITEM BY OWNER. 20 2-SIDED ICON. RE: OWNER DRAWINGS. 22 CANOPY ABOVE BY OWNER. 23 DROP SLAB IN PLAY AREA 1-1/2". RE: STRUCTURAL. 24 MDP. RE: ELECTRICAL. 25CT CABINET. RE: ELECTRICAL.FLOORPLAN KEYNOTES26HAND SANITIZER CENTERED UNDER PLAY RULES SIGNAGE (WITH DECAL ON OPPOSITE SIDE IF MOUNTED ON STOREFRONT). RE: SCHEDULE ON A-701 FOR MODEL INFO./A4A-604Chick-fil-A5200 Buffington Road Atlanta, Georgia 30349-2998Information contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from authorized project representatives.CONSULTANT PROJECT #PRINTED FORDATESHEETSHEET NUMBERDRAWN BYREVISION SCHEDULEA1234BCDEABCDE1234CHICK-FIL-ABUILDING TYPE / SIZE:RELEASE:#3/24/2021 1:47:46 PMBIM 360://MN_04807_Arden Hills FSU_2021.2_FSR/04807_Arden Hills FSU_ARC.rvtA-201FLOOR PLANPROJECT STATUS02/19/21AuthorARDEN HILLS (MN) FSU048073855 LEXINGTON AVENUEARDEN HILLS, MN 5512610-LS-04807-A-201-FLOOR PLAN####21.02P13 LSFSRI HEREBY CERTIFY THAT THESE PLANS HAVE BEENPREPARED UNDER MY SUPERVISION AND THAT TOTHE BEST OF MY KNOWLEDGE, THE SAME COMPLYWITH ALL RULES, REGULATIONS AND ORDINANCES OFARDEN HILLS, MN RELATING TO STRUCTURES ANDBUILDINGS.NOTE: SQUARE FOOTAGE INDICATED IN STATISTICS IS NET SQUARE FOOTAGE AND DOES NOT INCLUDED INTERIOR OR EXTERIOR WALLS. REFER TO FOOTPRINT FOR BUILDING SQUARE FOOTAGE.1/4" = 1'-0"FLOOR PLANC4WALL TYPE SCHEDULE - INTERIORMARK DESCRIPTION (DOES NOT INCLUDE FINISHES)M8 8" MTL STUDS @ 24" O.C. MAX, WITH ONE LAYER 1/2" SHEATHING EAEXPOSED SIDEW4 2x4 WD STUDS @ 24" O.C. MAX, WITH ONE LAYER 1/2" SHEATHING EAEXPOSED SIDEW6 2x6 WD STUDS @ 24" O.C. MAX, WITH ONE LAYER 1/2" SHEATHING EAEXPOSED SIDEW8 2x8 WD STUDS @ 24" O.C. MAX, WITH ONE LAYER 1/2" SHEATHING EAEXPOSED SIDEW64 2X6 & 2X4 PAIR WD STUDS @ 24" O.C. MAX, WITH ONE LAYER OF 1/2"SHEATHING EA EXPOSED SIDEBUILDING FOOTPRINT:WALL TYPE SCHEDULE - EXTERIORMARK DESCRIPTION (DOES NOT INCLUDE FINISHES)SM6 6" MTL STUD EXTERIOR WALL WITH 1/2" SHEATHING ON EXTERIORFACES - REF STRUCT DRAWINGS AND ARCH SECTIONS/ELEVATIONSFOR CONSTRUCTION/MATERIAL INFORMATIONSW6 2X6 WD STUD EXTERIOR WALL WITH 1/2" SHEATHING EA SIDE - REFSTRUCT DRAWINGS AND ARCH SECTIONS/ELEVATIONS FORCONSTRUCTION/MATERIAL INFORMATIONSW6.1 2X6 WD STUD EXTERIOR WALL WITH ONE LAYER 1/2" SHEATHINGEXTERIOR SIDE AND TWO LAYERS 1/2" SHEATHING INTERIOR SIDE -REF STRUCT DRAWINGS AND ARCH SECTIONS/ELEVATIONS FORCONSTRUCTION/MATERIAL INFORMATIONSW6.2 2X6 WD STUD EXTERIOR FURRING WALL WITH ONE LAYER 1/2"SHEATHING EXPOSED SIDE - REF STRUCT DRAWINGS AND ARCHSECTIONS/ELEVATIONS FOR CONSTRUCTION/MATERIAL INFORMATIONSTATISTICS (NET)Name AreaCLOSET 11 SFDINING 1571 SFDRIVE THRU 279 SFDTT CLOSET 27 SFKITCHEN 1518 SFMENS 188 SFOFFICE 56 SFRR VEST 83 SFSERVICE 149 SFSERVING 233 SFSTORAGE 63 SFTEAM MEMBER ROOM 225 SFVESTIBULE 57 SFWOMENS 181 SF4987 SFNO.DATEDESCRIPTION Attachment D