Laserfiche WebLink
SHEETDESIGNED <br />DRAWN <br />CHECKED <br />CLIENT PROJ. NO. <br />ISSUED FOR DATENO. <br />R <br />12224 NICOLLET AVENUE <br />BURNSVILLE, MINNESOTA 55337 <br />Phone: (952) 890-0509 <br />Email: Burnsville@bolton-menk.com <br />www.bolton-menk.com <br />ARDEN HILLS, MINNESOTA <br />LIFT STATION NO. 10 REHABILITATION <br />JEH <br />SWP <br />JEH <br />M20.121694 <br />0 04/05/2021 <br />56751DATELIC. NO. <br />SIGNATURE:PRINTED NAME: <br />TYPED OR Jacob E. Humburg <br />I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION OR REPORT WAS PREPARED BY ME OR UNDER MY <br />DIRECT SUPERVISION, AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF <br />THE STATE OF MINNESOTA <br />04/05/2021 <br />5.01EXISTING LIFT STATION DEMOLITION <br />PLAN AND SECTION Bolton & Menk, Inc. 2021, All Rights ReservedcH:\ARDH\M20121694\CAD\ENV\121694 DEMO LIFT STATION PLAN-SECTION.dwg 3/3/2021 8:44 PMREXISTING WET WELL AND VALVE VAULT - TOB SLAB PLAN <br />1/2" = 1'-0" <br />EXISTING WET WELL AND VALVE VAULT - PLAN <br />1/2" = 1'-0" <br />1 <br />5.01 <br />SECTION <br />1/2" = 1'-0" <br />1 <br />5.01 <br />Graphic Scale for 1/2"=1'-0" <br />1 20 643R ELEV=870.83 <br />ELEV=894.41 <br />ELEV=885.16 <br />ELEV=894.41 <br />8" PVC INFLUENT INV=872.02 <br />℄ <br />EXISTING <br />WET <br />WELL <br />EXISTING <br />WET <br />WELL <br />℄ <br />EXISTING <br />VALVE <br />VAULT <br />EXISTING <br />VALVE <br />VAULT <br />EXISTING HATCH <br />EXISTING CASTING <br />EXISTING 72" Ø MANHOLEEXISTING 72" Ø MANHOLE <br />℄ <br />EXISTING <br />WET <br />WELL <br />EXISTING <br />WET <br />WELL <br />℄ <br />EXISTING <br />VALVE <br />VAULT <br />EXISTING <br />VALVE <br />VAULT <br />EXISTING 4" CHECK VALVE <br />EXISTING 4" GATE VALVE <br />EXISTING 4" TEE WITH <br />BLIND FLANGE AND AIR <br />RELEASE <br />EXISTING 4" CHECK VALVE <br />EXISTING 4" GATE VALVE <br />EXISTING 4" TEE WITH <br />BLIND FLANGE AND AIR <br />RELEASE <br />EXISTING 4" 90° BEND <br />EXISTING 4" 90° BEND <br />EXISTING SUBMERSIBLE PUMP <br />EXISTING SUBMERSIBLE PUMP <br />EXISTING 4" <br />EXISTING 4" <br />EXISTING 4" <br />EXISTING 4"EXISTING 4" PVCINFLUENTEXISTING 72" Ø MANHOLE <br />EXISTING 72" Ø MANHOLE <br />EXISTING HATCHEXISTING CASTING <br />EXISTING CONC TOP SLABEXISTING CONC TOP SLAB <br />EXISTING <br />WET <br />WELL <br />EXISTING <br />VALVE <br />VAULT <br />EXISTING 72" Ø MANHOLE <br />REMOVE EXISTING 4" PIPING <br />IN WET WELL, UP TO AND <br />INCLUDING 90° ELBOWS <br />EXISTING 4" <br />EXISTING 4" CHECK <br />VALVE <br />EXISTING 4" GATE <br />VALVE <br />EXISTING 4" TEE WITH <br />BLIND FLANGE AND AIR <br />RELEASE <br />EXISTING 4" <br />℄ ELEV = 886.67 <br />EXISTING VALVE VAULT BASE SLAB <br />EXISTING SUBMERSIBLE PUMPS <br />EXISTING WET WELL BASE SLAB <br />REMOVE ALL FITTINGS <br />AND VALVES FROM <br />EXISTING VALVE VAULT <br />REMOVE EXISTING PUMPS, <br />BASE ELBOWS, RAILS, <br />CONTROLS, AND ALL <br />RELATED APPURTENCES <br />FROM EXISTING WET WELL <br />REMOVE ALL FITTINGS <br />AND VALVES FROM <br />EXISTING VALVE VAULT REMOVE ALL COMPONENTS <br />AND APPURTENANCES <br />FROM EXISTING WET WELL <br />REMOVE EXISTING <br />CONCRETE TOP SLAB <br />REMOVE EXISTING <br />CONCRETE TOP SLAB <br />EXISTING 72" Ø MANHOLE