Laserfiche WebLink
SHEET <br />DESIGNED <br />DRAWN <br />CHECKED <br />CLIENT PROJ. NO. <br />ISSUED FOR DATENO. <br />R <br />12224 NICOLLET AVENUE <br />BURNSVILLE, MINNESOTA 55337 <br />Phone: (952) 890-0509 <br />Email: Burnsville@bolton-menk.com <br />www.bolton-menk.com <br />ARDEN HILLS, MINNESOTA <br />LIFT STATION NO. 10 REHABILITATION <br />SJS <br />CML2 <br />SJS <br />0 04/05/2021 <br />7.02LIFT STATION ELECTRICAL DETAILS <br />18925DATELIC. NO. <br />SIGNATURE:PRINTED NAME: <br />TYPED OR Sheldon J. Sorensen <br />I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION OR REPORT WAS PREPARED BY ME OR <br />UNDER MY DIRECT SUPERVISION, AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER <br />UNDER THE LAWS OF THE STATE OF MINNESOTA <br />04/05/2021FILE: M:\ADEPTWORK\CHAD LAKOSE\23191319.58_7.02.DWG2021 Barr Engineering CompanyCSEE GENERAL DRAWINGS FOR PLAN <br />LAYOUT AND EQUIPMENT LOCATIONS. <br />NOTE: <br />PUMP AND LEVEL <br />SENSOR CABLES. <br />CABLE HOLDER BY HATCH MFR6" THICK CONCRETE PAD <br />W/ 6"x 6" 10/10 W.W.F. SEE <br />PLAN FOR DIMENSIONS <br />VENTILATED ENCLOSURE. VENTILATION LOUVERS TO BE 12"x36" <br />(MINIMUM) ON BOTH FRONT & BACK PANELS W/LOUVER BLADES IN A <br />DOWNWARD & OUTWARD DIRECTION & INSECT SCREEN INSIDE <br />ENCLOSURE. <br />CROUSE-HINDS TYPE CGB CONNECTORS. ONE PER CABLE. SIZE PER <br />CABLE O.D. <br />LIFT STATION CONTROL ENCLOSURE. <br />5' EXTRA EACH CABLE. <br />TYPICAL. <br />SCHEDULE 80 PVC CONDUITS. <br />SEE PLAN. <br />CONDUITS PER PLAN <br />GROUND ROD(S) PER <br />PLAN. <br />GROUND CONDUCTOR(S) <br />PER PLAN <br />12" LAYER COMPACTED <br />SAND. <br />GRADE <br />SEAL CONDUITS W/ 1/4" <br />SILICONE CAULK <br />PUMP AND LEVEL SENSOR <br />CABLES. TYPICAL <br />48" MIN.18"BELL ENDS <br />PUMP CABLE BY MFR. <br />30A/3P <br />MCP-TYPE <br />20A/1P 15A/1P 15A/1P <br />WETWELLFLOATSWITCHESPANEL INTERNAL HEATERGFCI RECEPTACLEPANEL MOUNTED100A/3P <br />100A/3P <br />4-1/C-#3-1.5" <br />SCHEDULE 80 PVC <br />100A <br />120/208V, <br />3Ø <br />NEMA 3R <br />METER <br />120/208V, <br />3Ø, 4W <br />UTILITY <br />SERVICE 4-1/C-#3-1.5" <br />SCHEDULE 80 PVC <br />GROUND <br />RODS. <br />SEE <br />PLAN <br />NEUTRAL BUS <br />GROUND BUS <br />PUMP 1PUMP 2CONTROL <br />EQUIPMENT. <br />SEE <br />SPECIFICATION <br />CELL PHONE <br />ALARM SYSTEM. <br />SEE SPECIFICATION <br />TO UTILITY <br />SERVICE <br />UTILITY METER. <br />VERIFY <br />LOCATION. <br />PHASE <br />MONITOR/ <br />VOLTAGE <br />RELAY <br />TRANSIENT <br />VOLTAGE <br />SURGE <br />SUPPRESSOR <br />(TVSS)NEMA <br />SIZE 2 <br />STARTER <br />NEMA <br />SIZE 2 <br />STARTER <br />WETWELLLEVELTRANSMITTERCELL PHONE <br />ANTENNA <br />30A/3P <br />MCP-TYPEMECHANICAL <br />INTERLOCK <br />CROUSE-HINDS <br />100A, 4P <br />PIN & SLEEVE <br />CONNECTOR W/ <br />ANGLE ADAPTER <br />AND SPRING COVER <br />COMPATIBLE W/ <br />OWNER'S PORTABLE <br />GENERATOR PLUG. <br />LIFT STATION SECTION <br />NO SCALE <br />ONE-LINE DIAGRAM <br />NO SCALE <br />5HP <br />15A <br />5HP <br />15A <br />100A, 120/208V, 3Ø, 4W, BUSSING, 35KAIC RATING <br />WHM