Laserfiche WebLink
Bolton & Menk, Inc. <br />Proposal QTB172950 <br />February 17, 2023 <br />Page 2 <br />Depending on access requirements, ground conditions or potential utility conflicts, our field crew may <br />alter the exploration locations from those proposed to facilitate accessibility. <br />Our drilling activities may also impact the vegetation and may rut the surface to access boring locations. <br />Restoration of vegetation and turf, if disturbed, is not part of our scope of services. <br />Staking <br />We will stake prospective subsurface exploration locations, as selected in consultation with you, and <br />obtain surface elevations at those locations using GPS (Global Positioning System) technology. For <br />purposes of linking the GPS data to an appropriate reference, we request that you provide CAD files <br />indicating location/elevation references appropriate for this project. <br />Utility Clearance <br />Prior to drilling or excavating, we will contact Gopher State One Call and arrange for notification of the <br />appropriate utility vendors to mark and clear the exploration locations of public underground utilities. <br />You, or your authorized representative, are responsible to notify us before we begin our work of the <br />presence and location of any underground objects or private utilities that are not the responsibility of <br />public agencies. <br />Permits <br />We will obtain a right-of-way permit with the City of Arden Hills prior to beginning our fieldwork. We <br />assume the City will waive permit fees as we will be completing the work for the City. <br />Traffic Control <br />Based on the low traffic levels on James Avenue, we propose to limit our traffic control to signs and <br />cones to alert motorists to our work in the area. <br />Penetration Test Borings <br />We propose to drill two standard penetration test (SPT) borings for the project to nominal depths of <br />141/2 feet. We will perform standard penetration tests at 2 1/2-foot vertical intervals to a depth of <br />about 14 1/2 feet, and at 5-foot intervals at greater depths, if required. <br />If the intended boring depths do not extend through unsuitable material, we will extend the borings at <br />least 5 feet into suitable material at greater depths. The additional information will help evaluate such <br />issues as excavation depth and consolidation settlement among others. If we identify a need for deeper <br />(or additional) borings, we will contact you prior to increasing our total estimated drilled footage and <br />submit a Change Order summarizing the anticipated additional effort and the associated cost, for your <br />review and authorization. <br />Groundwater Measurements <br />If the borings encounter groundwater during or immediately after drilling of each boring, we will record <br />the observed depth on the boring logs. <br />MDH Notification and Sealing Record <br />Since our planned exploration will be less than 15 feet in depth, the Minnesota Statutes will not require that <br />we complete any notifications or sealing records. If we extend any of the borings to a depth of 15 feet or <br />BRAUN <br />INTERTEC <br />