Laserfiche WebLink
Bolton & Menk, Inc. <br />Project B2204011.00 <br />May 9, 2023 <br />Page 3 <br /> <br />Summary <br /> <br />While copper, non-carcinogenic PAHs, and carcinogenic PAHs were detected across the Site, none of the <br />samples contained concentrations greater than MPCA SRVs. <br /> <br />Quality Assurance/Quality Control <br /> <br />Samples were placed in clean, laboratory supplied containers, preserved, labeled, and transported to the <br />Pace laboratory under refrigerated conditions using chain-of-custody procedures. Analyses were <br />performed using EPA or other recognized standard procedures. A quality assessment of field procedures <br />and analytical laboratory reports was performed to evaluate potential effects on data quality used to <br />support project objectives. All applicable Braun Intertec SOPs were followed as prescribed unless <br />otherwise noted in this report. <br /> <br />Due to high moisture content and to provide the highest-resolution results, analytical results were <br />reported to the method detection limit, which introduced “J” flagged results, which are considered <br />estimated concentrations, reported at less than the laboratory reporting limit. The results were reported <br />to the method detection limit, and the data was evaluated using the MPCA standard procedures as <br />described in Appendix B of “Managing Stormwater Sediment BMP Guidance for Municipalities.” <br /> <br />Recommendations <br /> <br />Based on analytical results from our sampling and testing, excavated stormwater sediments from the <br />Colleen Avenue project area fall within the Residential/Recreational SRV management category and may <br />be used with no restrictions. <br /> <br />General <br /> <br />Our scope of our work was determined by our understanding of the rules and guidance of the MPCA as <br />they apply to needs of Bolton & Menk, Inc., working on behalf of the City of Arden Hills. Therefore, the <br />scope of work is not represented to conform explicitly to current MPCA written guidance. <br /> <br />