Laserfiche WebLink
on Connelly Avenue with a reading of 1.4 foot candles. As a condition of approval, all lighting <br />shall be downward directed shoebox style with flush lenses. Details about the proposed lighting <br />are found in Attachment H. <br />D. Site Furnishings — Flexibility Requested <br />Section 1325.05 Subd. 8, J, establishes provisions for site furnishings and seating areas for new <br />development, redevelopment, and modifications to existing sites in the B-2 Zoning District. Per <br />the code, benches and decorative plantings shall be provided near the primary entrance of all <br />buildings on a site. <br />At the July 10, 2024 Planning Commission meeting, Condition 18 was added to the recommended <br />conditions of approval, reading "The Applicant shall provide benches near the primary entrance <br />of the building." The Applicant has submitted updated Architectural and Civil Plans indicating a <br />bench to be placed near the main entrance to the restaurant space. <br />Also noted in J of Subd. 8, restaurants shall include a functional outdoor seating area with tables, <br />chairs, planting and access to the restaurant. As a restaurant is part of the Master PUD, and the use <br />will be established at the Subject Property in Phase II of development, the proposed development <br />is subject to this requirement. The Applicant noted in this application that there are no plans for an <br />outdoor seating area and that the porch area on the east side of the building is a designated smoke <br />area and would not be used for outside seating for the restaurant or the event center. <br />The Applicant also stated as part of the narrative that the proposed development is intended to be <br />fully enclosed to ensure noise is contained within the venue. The City Council may comment on <br />the proposed site furnishings as they apply to both Phase I and Phase II of development. <br />E. Screening — For Review <br />Under Section 1325.05, Subd. 8, K, Trash and recycling equipment, materials, and containers shall <br />be fully enclosed and integrated into the architecture of the buildings. All mechanical equipment, <br />whether roof -mounted or ground -mounted should be integrated into the architecture of the <br />building. It shall be completely screened from the ground -level view of adjacent properties and <br />public streets. Wood screening shall not be permitted. <br />There is a trash enclosure proposed for the Subject Property and located on the north side of the <br />site. This enclosure will feature metal trash enclosure gates and the other three elevations will be <br />constructed of a metal panel material consistent with the building design. <br />The Applicant has noted that all mechanical equipment is located on the ground along the west <br />side of the building. There are no existing roof -mounted systems, and none will be added as part <br />of the proposed development. The Applicant is proposing all ground mounted mechanical <br />equipment will be screened from view by new on -site landscaping which is shown in the <br />landscaping plans in Attachment F. The Applicant states that the equipment will not be visible <br />from the right of way on the west side of Snelling Avenue. <br />At the July 10, 2024 Planning Commission meeting, Condition 20 was added to the conditions of <br />approval, reading "Screening for ground -mounted mechanical equipment shall meet the <br />requirements of the Zoning Code." In updated landscaping plans, the Applicant updated the <br />proposed screening plantings to an evergreen shrub to provide year-round screening. The updated <br />narrative includes a statement from the landscape engineer, stating that the proposed planting will <br />Page 15 of 23 <br />