V1 <br />I" X 2" X 24" LONG WOODEN STAKES. <br />STAKES SHALL BE DRIVEN THROUGH THE <br />BACK HALF OF THE SEDIMENT CONTROL LOG SEDIMENT CONTROL LOG <br />AT AN ANGLE OF 45 DEGREES WITH THE <br />TOP OF THE STAKE POINTING UPSTREAM. QI <br />45' <br />FLOW <br />BACKFILL AND COMPACT SOIL FROM B"-1[ <br />TRENCH ON UPGRADIENT SIDE OF .�•� <br />SEDIMENT CONTROL LOG <br />PLACE SEDIMENT CONTROL <br />LOG IN SHALLOW TRENCH <br />(1" TO 2" DEPTH) <br />TYPES, STRAW, WOOD FIBER, OR COIR <br />EMBEDMENT DEPTH <br />1" X 2" X 24" LONG WOODEN STAKES AS <br />NEEDED. STAKES SHALL BE DRIVEN OVER <br />THE SEDIMENT CONTROL LOG AT AN ANGLE <br />OF 45 DEGREES WITH THE TOP OF THE SEDIMENT CONTROL LOG <br />STAKE POINTING UPSTREAM. 02 <br />FLOW <br />45' <br />8"-10" EMBEDMENT DEPTH ,•`•'- <br />TYPES: WOOD CHIP, COMPOST, OR ROCK <br />SEDIMENT CONTROL LOGS <br />POINT <br />GEOTEXTILE FABRIC TYPE IV (SPEC. 3T31 <br />ALONG BOTTOM OF RIPRAP <br />•�•'i <br />ROCK DITCH CHECKS <br />FILTER BERMS TYPE 3 (ROCK WEEPER)OR FILTER TYPE 5 (ROCK) 03 <br />FOR USE ON ROUGH -GRADED AREAS <br />ONLY FOR USE OUTSIDE CLEAR ZONE 02 <br />BOTTOM OF UPPER CHECK SHOULD BE SAME <br />ELEVATION AS THE TOP OF THE LOWER <br />CHECK TO PROVIDE FOR POOLING <br />FLOW FILTER BERM TYPE 3 OR 5 <br />—' (SHOWN) <br />SPACING (Y) DETERMINED Y <br />BY FORMULA (SEE NOTES) <br />DITCH CHECK SPACING <br />FOR ALL FILTER BERM TYPES <br />COMPOST,SLASH REPP CATEGORY 25 (BLANKET) <br />COARSE FILTER AGGREGATE MULCH, OR TOPSOIL "'j I" X 2" X 24" LONG WOODEN STAKES AT 12" MAXIMUM <br />12 SLOPE <TYPI CLASS ]I RIPRAP 1^ \ BLANKET ANCHOR TRENCH. SPACING. STAKES SHALL BE DRIVEN THROUGH THE BACK HALF <br />4" X 4" TRENCH BACKFILLED OVER OF THE SEDIMENT CONTROL LOG AT AN ANGLE OF 45 <br />CLASS I RIPRAP NATURAL WITH TAMPED <br />DITCH EROSION CONTROL BLANKET <br />2' DITCH PROFILE 2' 2''y::;� DITCH POINT POINT NATURAL SOIL. DEGREES WITH THE TOP OF THE STAKE POINTING UPSTREAM. <br />WATER PROFILE MIN• ,,.,, . f•,.•• PROFILE "B" Y "A' 10 <br />FLOW —� ••'•' ai SEDIMENT CONTROL LOG TYPE WOOD FIBER <br />8,I REPP CATEGORY 25 <br />4MIN' <br />TYPE IV GEOTEXTILE 5' TYPE IV GEOTEXTILE 4" MINIMUM FLOW 8'MINIMUM WIDTH <br />ALONG BOTTOM ALONG BOTTOM \ <br />OF FILTER BERM OF FILTER BERM �J• •'� ••✓ •i <br />TYPE 3 (ROCK WEEPER) TYPE 5 (ROCK) TYPE 1 (COMPOST). TYPE 2 (SLASH a V <br />STAPLE BLANKET IN ROWS WITH 6" STAPLES AT IB" <br />0 8", 11 GA. STAPLES 4" MINIMUM MAXIMUM SPACING WITHIN ROWS AND 24" MAXIMUM <br />MULCH), OR TYPE 4 (TOPSOIL) o SPACED 12" ON CENTER SPACING BETWEEN ROWS. <br />TRAILING GE <br />FILTER BERMS THY ICA E STAPLED APPROXIMATELY 6" FROMEDGE. <br />TWO 2" X 2" WOOD STAKES OR <br />°i <br />REPP CATEGORY 25 <br />6'WIDE MINIMUM Q <br />REINFORCING BARS IN EACH BALE <br />EMBEDDED 10" MINIMUM IN THE -_ - <br />_ <br />_ <br />NOTES: <br />^ GROUND. FLOW - = STANDING <br />FLOW - STANDING <br />LO <br />REPP = ROLLED EROSION PREVENTION PRODUCT. <br />y - WATER <br />s - WATER <br />- 7 <br />SEE SPECS. 2573, 3149, 3874, 3882, 3885, 3886, AND 3897. <br />'L <br />QI SPACE BETWEEN STAKES SHALL BE A MAXIMUM OF I'FOR DITCH CHECKS OR 2'FOR OTHER <br />EMBED BALES 4" INTO GROUND 4„ <br />y <br />6" STAPLES AT V O.C. <br />APPLICATIONS. <br />EMBEDMENT METHOD <br />REPP (BLANKET) METHOD (ALTERNATE) <br />02 PLACE STAKES AS NEEDED TO PREVENT MOVEMENT OF SEDIMENT CONTROL LOGS PLACED ON <br />a <br />SLOPES OR AS NEEDED DUE TO OTHER FACTORS. STAKES SHALL BE INCIDENTAL. <br />c <br />BALE <br />BARRIERS03 <br />(DTO BE USED FOR CRITICAL PERIMETER CONTROL AREAS WHERE STANDING WATER OCCURS IS" <br />MAXIMUM DEPTH). BALES SHALL CONSIST OF TYPE I MULCH OF APPROXIMATELY 141, X Is" X 361, <br />LONG. BALES SHALL BE PLACED ON EDGE AND BUTTED TIGHT TO ADJACENT BALES. <br />04 INSTEAD OF TRENCHING, PLACE BALE ON THE REPP (BLANKET)AND WRAP BLANKET AROUND THE <br />BALE. PLACE STAKE THROUGH BALE AND BLANKET. <br />REVISION: <br />STANDARD PLAN <br />5-297.405 2 OF 8 <br />M11 <br />TEMPORARY SEDIMENT CONTROL <br />APPROV DI JANUARY S. 2020 <br />--------- --- taIXAiF'-- <br />MINN250TA <br />APPROVED: I-8-2020 <br />REVISED: FILTER BERMS,SEDIMENT CONTROL LOGS,AND BALE BARRIERS <br />x „A"",s,: <br />R� FNYYpNEIIT.L WIM <br />DEPARTMENT <br />OF <br />I <br />o <br />STATE PROD. NO. (T.H. ) SHEET NO. OF SHEETS <br />TI OIWAnox <br />srATE N ENGINEER <br />INLET SPECIFICATIONS AS PER THE PLAN <br />DIMENSION LENGTH AND WIDTH TO MATCH <br />MINIMUM DOUBLE <br />STITCHED SEAMS ALL <br />AROUND SIDE PIECES <br />AND ON FLAP POCKETS <br />I I.MY1, OM.,I., XIYV <br />BOTTOM TO BE <br />MADE FROM SINGLE <br />PIECE OF FABRIC. <br />T' <br />o I GROUND <br />FILTER BAG INSERT (O <br />(CAN BE INSTALLED IN ANY INLET TYPE <br />WITH OR WITHOUT A CURB BOX) <br />e" <br />USE REBAR OR STEEL ROD <br />411 FOR REMOVAL ( FOR INLETS <br />WITH CAST CURB BOX REPLACE <br />ROD WITH WOOD 2" X 4"). <br />EXTEND 10" BEYOND GRATE <br />12' WIDTH ON BOTH SIDES, LENGTH <br />VARIES. SECURE TO GRATE WITH <br />WIRE OR PLASTIC TIES <br />OVERFLOW HOLES 12" X 4" HOLE SHALL <br />BE HEAT CUT INTO ALL FOUR SIDE PANELS) <br />INGEST <br />CATCH BASIN/ <br />_ <br />0 <br />MANHOLE <br />N <br />1 <br />SEDIMENT CONTROL INLET HAT <br />gw <br />c <br />12' <br />�m <br />- w <br />m <br />NOTE: <br />THE SEDIMENT CONTROL BARRIER SHALL BE A METAL <br />OR PLASTIC/POLYETHYLENE RISER SIZED TO FIT INSIDE <br />THE CATCH BASIN/MANHOLEIHAVE PERFORATIONS TO ALLOW <br />FOR WATER INFILTRATION: HAVE AN OVERFLOW OPENING, <br />FLANGES AND A LID/COVER. <br />REVISION: <br />APPROVVEEDD,:,�2-28-2017 <br />Rmr DRNRIIEXi.1L olriDn <br />ENDS SECURELY CLOSED TO <br />PREVENT LOSS OF OPEN GRADED <br />AGGREGATE FILL. SECU <br />50 PSI. ZIP TIE. <br />JOI <br />ROCK LOG/COMPOST LOG <br />3/16" THICK (MIN.) <br />STEEL COVER <br />6" DIAMETER <br />POLYETHYLENE <br />0 �21/2" <br />0 4 <br />1 N <br />II 0 2„ <br />kv� <br />TUBE RISER <br />0 ADJUST LEVEL OF FILTER <br />x SOCK TO BE BELOW ROAD <br />i <br />i <br />N SURFACE ELEV. 5Q <br />SECTION <br />(UP POSITION) <br />TUBE <br />l (MIN.) <br />LATE <br />PERSPECTIVE VIEW <br />3/16" THICK (MIN.) <br />STEEL PLATE <br />0 <br />0 <br />0 <br />0 ,,x <br />SECTION <br />(DOWN POSITION) <br />SPACING <br />POP-UP HEAD <br />5'MIN. LENGTH POST <br />DROP INLET WITH GRATE <br />36" GEOTEXTILE <br />REINFORCED WITH <br />WIRE 1 <br />r.`: �`:i <br />�9 . <br />NOTES - <br />PLASTIC <br />ASTIC ZIP TIES <br />'^�"":. �;, <br />s: <br />SEE SPECS. 2573,3137,E 3886. <br />0 LB TENSILD HOLDS <br />.<. �:Y.:;. <br />Y: <br />i <br />DEVICES MUST BE ADJUSTED ACCORDINGLY AS TO NOT CAUSE FLOODING ON ROADWAY <br />C(GEOTEXTILEIN PLACE i <br />THAT WOULD IMPEED TRAFFIC FLOW. <br />• ..: .. .,,.,.N <br />ALL POSTS 1 <br />ALL GEOTEXTILE USED FOR INLET PROTECTION SHALL BE MONOFILAMENT IN BOTH <br />DIRECTIONS, MEETING SPEC. 3886. <br />PE 9 MULCH <br />FINISHED SIZE INCLUDING POCKETS WHERE REQUIRED SHALL EXTEND A MINIMUM OF <br />10 INCHES AROUND THE PERIMETER TO FACILITATE MAINTENANCE OR REMOVAL. <br />Q <br />INSTALLATION NOTES: <br />DO NOT PLACE FILTER BAG INSERT IN INLETS SHALLOWER THAN 30 INCHES. <br />MEASURED FROM THE BOTTOM OF THE INLET TO THE TOP OF THE GRATE. THE <br />PLACED BAG SHALL HAVE A MINIMUM SIDE CLEARANCE OF 3 INCHES BETWEEN <br />- - - - <br />THE INLET WALLS AND THE BAG, MEASURED AT THE BOTTOM OF THE OVERFLOW HOLES. <br />WHERE NECESSARY THE CONTRACTOR SHALL CLINCH THE BAG, USING PLASTIC ZIP TIES, <br />GEOTEXTILE ANCHORAGE <br />TO ACHIEVE THE 3 INCH SIDE CLEARANCE. <br />LAY GEOTEXTILE UNDER <br />Qq <br />FLAP POCKETS SHALL BE LARGE ENOUGH TO ACCEPT WOOD 2 INCH X 4 INCH OR USE A <br />TYPE 9 MULCH 12" OUT <br />ROCK SOCK OR SAND BAGS IN PLACE OF THE FLAP POCKETS. <br />05 <br />SOCK HEIGHT MUST NOT BE SO HIGH AS TO SLOW DOWN WATER FILTRATION TO CAUSE <br />FLOODING OF THE ROADWAY. <br />© <br />GEOTEXTILE SOCK BETWEEN 4-10 FEET LONG AND 4-6 INCH DIAMETER. SEAM TO BE <br />JOINED BY TWO ROWS OF STITCHING WITH A PLASTIC MESH BACKING OR PROVIDE A <br />SILT <br />FENCE RING AND ROCK FILTER BERM <br />HEAT BONDED SEAM (OR APPROVED EQUIVALENT). FILL ROCK LOG WITH OPEN GRADED <br />USE WHERE <br />INLET DRAINS IN AN AREA WITH SLOPES AT 113 or LESS <br />AGGREGATE CONSISTING OF SOUND DURABLE PARTICLES OF COARSE AGGREGATE <br />CONFORMING TO SPEC. 3137 TABLE 3137-11 CA-3 GRADATION. <br />STANDARD PLAN 5-297.405 4 OF 8 <br />M11 <br />TEMPORARY SEDIMENT CONTROL <br />APPROVED: 2-28-2017 <br />MINN250TA <br />REVISED: <br />STORM DRAIN INLET PROTECTION <br />DEPARTMENT <br />f STATE PROD. N0. <br />(T.H. ) SHEET NO. OF SHEETS <br />TIwNSPOWAnox <br />D� ENGINEER <br />SEDIMENT CONTROL LOG TYPE REPP (BLANKET) SYSTEM 40 <br />O <br />SEDIMENT CONTROL LOG TYPE WOOD FIBER, OR TYPE COMPOST 05 <br />FOR USE ON ROUGH GRADED AREAS <br />PUBLIC ROAD <br />RADIUS AS <br />REQUIRED 0 <br />SLASH MULCH. <br />CRUSHED ROCK, <br />SHEET PAD, OR <br />O <br />OTHER PER <br />SEDIMENT04 <br />SPECIFICATION. <br />TRAP <br />SURFACE OW <br />ENTRANCE WIDTH <br />AS REQUIRED <br />SLASH MULCH, CRUSHED ROCK, OR SHEET <br />PAD CONSTRUCTION EXIT 05 07 <br />HIGH STRENGTH GEOTEXTILE FABRIC <br />(TWO LAYERS SEWN TOGETHER TO <br />FORM POCKETS) <br />TRAFFIC FLOW <br />MIN. 2" DIA. HIGH TENSIL <br />REINFORCED RIBS <br />SHEET PAD <br />c <br />y <br />NOTES: <br />REPP = ROLLED EROSION PREVENTION PRODUCT. <br />SEE SPECS. 25T3.3601.3733.3885.3886 6 3689. <br />FOR DITCH CHECKS. PLACE SEDIMENT CONTROL LOG PERPENDICULAR TO FLOW AND IN A CRESCENT SHAPE WITH <br />THE ENDS FACING UPSTREAM. <br />APPROXIMATE SPACING BETWEEN EACH DITCH CHECK SHOULD BE DETERMINED FROM THE FOLLOWING SPACING FORMULA. <br />DITCH CHECK HEIGHT (FT.) <br />APPROXIMATE SPACING OF DITCH CHECKS (FT.) = Y = X 100 <br />X CHANNEL SLOPE <br />(D POINT "A" MUST BE A MINIMA OF 6' HIGHER THAN POINT "B" TO ENSURE THAT WATER FLOWS OVER THE DIKE <br />AND NOT AROUND THE ENDS. <br />02 ROCK DITCH CHECKS PLACED WITHIN THE CLEAR ZONE ARE TO BE 18' OR LESS IN HEIGHT. A L6 APPROACH AND <br />DEPARTURE SLOPE SHALL BE PROVIDED. <br />© DITCH GRADE 3X - 5X, MAX. FLOW VELOCITY 12 FT --AC. <br />Q DITCH GRADE LSX - 3X. MAX. FLOW VELOCITY 4.5 FT./SEC. <br />© DITCH GRADE LSX - 3X. MAX. ROW VELOCITY L5 FT./SEC. <br />PUBLIC ROAD <br />10 F. <br />MIN. RADIUS AS <br />REQUIRED O <br />CORRUGATED STEEL PANELS <br />GEOTEXTILE FABRIC <br />TAPER EDGES <br />AT 1:1 <br />'C CROSS SLOPE 3X OR FLATTER <br />A- <br />10 FT <br />MIN. <br />6" MIN. DEPTH OF 1" TO 2" <br />A <br />CRUSHED ROCK OR SLASH MULCH <br />GEOTEXTILE FABRIC <br />TAPER EDGES <br />i <br />AT 1:1 <br />6" MIN. <br />INPLACE <br />GROUND <br />REVISION: <br />SLASH MULCH <br />OR CRUSHED ROCK <br />APPROVED:2-28-2017 <br />- Rmr DlrwalExru olriDn <br />SLASH MULCH, <br />CRUSHED ROCK, <br />SHEET PAD, OR <br />OTHER PER <br />SPECIFICATION. <br />ENTRANCE WIDTH <br />AS REQUIRED <br />RUMBLE PAD <br />CONSTRUCTION EXIT OO 07 <br />M3 STANDARD PLAN 5-297.405 1 5 OF 8 <br />APPROVED:2-28-2017 <br />MINN250TA / REVISED: <br />DEPARTMENT / I <br />TIwNSPOFAnox srATE D N ENGINEER STATE PROJ. NO. <br />6" MIN. DEPTH OF 1" <br />COMPACTED SOIL TO 2" CRUSHED ROCK OR <br />SLASH MULCH <br />RUMBLE PAD <br />NOTES: <br />SEE SPECS. 2573 9 3882. <br />1Q MINIMUM LENGTH SHALL BE THE GREATER OF 50 FEET OR A LENGTH SUFFICIENT TO <br />ALLOW A MINIMUM OF 5 TIRE ROTATIONS ON THE PROVIDED PAD. MINIMUM LENGTH <br />SHALL BE CALCULATED USING THE LARGEST TIRE WHICH WILL BE USED IN TYPICAL <br />OPERATIONS. <br />Q PROVIDE RADIUS OR WIDEN PAD SUFFICIENTLY TO PREVENT VEHICLE TIRES FROM <br />TRACKING OFF OF PAD WHEN LEAVING SITE. <br />3 IF RUNOFF FROM DISTURBED AREAS FLOWS TOWARD CONSTRUCTION EXITS. PREVENT <br />RUNOFF FROM DRAINING DIRECTLY TO PUBLIC ROAD OVER CONSTRUCTION EXIT BY <br />CROWNING THE EXIT OR SLOPING TO ONE SIDE. IF SURFACE GRADING IS <br />INSUFFICIENT, PROVIDE OTHER MEANS OF INTERCEPTING RUNOFF. <br />40 IF RUNOFF FROM CONSTRUCTION EXITS WILL DRAIN OFF OF PROJECT SITE. PROVIDE <br />SEDIMENT TRAP WITH STABILIZED OVERFLOW. <br />50 IF A TIRE WASH OFF IS REQUIRED THE CONSTRUCTION EXITS SHALL BE GRADED TO <br />DRAIN THE WASH WATER TO A SEDIMENT TRAP. <br />© MINIMUM LENGTH OF RUMBLE PAD SHALL BE 20 FEET, OR AS REQUIRED TO REMOVE <br />SEDIMENT FROM TIRES. IF SIGNIFICANT SEDIMENT IS TRACKED FROM THE SITE, THE <br />RUMBLE PAD SHALL BE LENGTHENED OR THE DESIGN MODIFIED TO PROVIDE <br />ADDITIONAL VIBRATION. WASH -OFF LENGTH SHALL BE AS REQUIRED TO EFFECTIVELY <br />REMOVE CONSTRUCTION SEDIMENT FROM VEHICLE TIRES. <br />Q7 MAINTENANCE OF CONSTRUCTION EXITS SHALL OCCUR WHEN THE EFFECTIVENESS OF <br />SEDIMENT REMOVAL HAS BEEN REDUCED. MAINTENANCE SHALL CONSIST OF REMOVING <br />SEDIMENT AND CLEANING THE MATERIALS OR PLACING ADDITIONAL MATERIAL (SLASH <br />MULCH OR CRUSHED ROCK)OVER SEDIMENT FILLED MATERIAL TO RESTORE <br />EFFECTIVENESS. <br />TEMPORARY SEDIMENT CONTROL <br />STABILIZED CONSTRUCTION EXIT <br />(T.H. ) SHEET NO. OF SHEETS <br />J <br />Q <br />Z W <br />a <br />Z <br />OYZf <br />V <br />Z <br />Z W OC <br />f <br />V <br />c�Iz> <br />W <br />Z <br />i <br />W ((A W <br />0 <br />J <br />M <br />gn <br />j <br />Z <br />0Q <br />O <br />V <br />O x <br />LLI <br />F <br />h <br />M <br />W <br />n <br />a <br />Z <br />a; <br />BD <br />Rt <br />Fe <br />0 <br />n <br />W <br />V0 <br />0 <br />LL <br />V <br />~° <br />QN <br />It <br />d <br />It <br />IL <br />M <br />� <br />0 <br />M <br />F <br />Z <br />O <br />r <br />N <br />-J <br />0 <br />En <br />a� <br />C <br />W <br />I"I <br />2 <br />W <br />2 <br />p <br />2Q <br />O <br />Z <br />V <br />J <br />J <br />i <br />ZLf) .-•I <br />LLI O <br />T <br />a z Ln <br />W z <br />0 > <br />p <br />\W L= <br />/ r <br />W N O <br />U <br />O <br />O <br />ZT-'Lf) <br />W <br />F�1 <br />r <br />REVISIONS <br />1. 07/17/24 Per City Comments <br />DRAWN BY: <br />DJW <br />DESIGNED BY: <br />DJW <br />ISSUE DATE: <br />07/01/24 <br />I hereby certify that this plan, specification <br />or report was prepared by <br />me or under <br />my <br />direct supervision and that <br />I am <br />a duly <br />Licensed Professional Engineer <br />under <br />the <br />laws of the State of Minnesota <br />Name: DGGaa�n J.W//��ilke, <br />P.E. <br />Signature: 9 <br />d,i7A' <br />Date: 07/01/24 License #: 53182 <br />C8.3 <br />of <br />8 <br />