Laserfiche WebLink
#=NA# <br />PROJECT NARRATIVE <br />Pace Project No.: <br />Project: <br />10732220 <br />B2502087 2026 PMP Inprovements <br />Method: <br />Client:Braun Intertec Corporation <br />EPA 8270E by SIM <br />Date:May 05, 2025 <br />Description:8270E MSSV PAH by SIM <br />General Information: <br />5 samples were analyzed for EPA 8270E by SIM by Pace Analytical Services Minneapolis. All samples were received in acceptable <br />condition with any exceptions noted below or on the chain-of custody and/or the sample condition upon receipt form (SCUR) attached <br />at the end of this report. <br />Hold Time: <br />The samples were analyzed within the method required hold times with any exceptions noted below. <br />Sample Preparation: <br />The samples were prepared in accordance with EPA 3546 with any exceptions noted below. <br />Initial Calibrations (including MS Tune as applicable): <br />All criteria were within method requirements with any exceptions noted below. <br />Continuing Calibration: <br />All criteria were within method requirements with any exceptions noted below. <br />Internal Standards: <br />All internal standards were within QC limits with any exceptions noted below. <br />Surrogates: <br />All surrogates were within QC limits with any exceptions noted below. <br />Method Blank: <br />All analytes were below the report limit in the method blank, where applicable, with any exceptions noted below. <br />Laboratory Control Spike: <br />All laboratory control spike compounds were within QC limits with any exceptions noted below. <br />Matrix Spikes: <br />All percent recoveries and relative percent differences (RPDs) were within acceptance criteria with any exceptions noted below. <br />QC Batch: 1003652 <br />A matrix spike and/or matrix spike duplicate (MS/MSD) were performed on the following sample(s): 10732220001 <br />M1: Matrix spike recovery exceeded QC limits. Batch accepted based on laboratory control sample (LCS) recovery. <br />• MS (Lab ID: 5234085) <br />• Benzo(g,h,i)perylene <br />• Fluoranthene <br />• Phenanthrene <br />• Pyrene <br />• MSD (Lab ID: 5234086) <br />• Benzo(g,h,i)perylene <br />• Fluoranthene <br />• Phenanthrene <br />REPORT OF LABORATORY ANALYSIS <br />This report shall not be reproduced, except in full, <br />without the written consent of Pace Analytical Services, LLC. <br />Pace Analytical Services, LLC <br />1700 Elm Street <br />Minneapolis, MN 55414 <br />(612)607-1700 <br />Page 5 of 23