Laserfiche WebLink
RESERVE <br />ADVISORS <br />Priority/Criticality: Defer only upon opinion of independent professional or engineer <br />Expenditure Detail Notes: Expenditure timing and costs are depicted in the Reserve <br />Expenditures table in Section 3. <br />Walls, Mason <br />Line Item: 1.820 <br />Quantity: Approximately 6,700 square feet of masonry comprises the exterior walls <br />History: No reported occurrences of significant coordinated repairs. Management <br />informs us the sealants have been replaced on an as needed basis. <br />Condition: Good to fair overall with the following evident: <br />• Minimal previous repairs evident <br />• Efflorescence is not visible <br />• Lintels exhibit corrosion and paint finish peeling/deterioration <br />• Masonry exhibits isolated occurrences of cracks <br />• Masonry exhibits isolated occurrences of spalls <br />• No significant mortar deterioration is evident <br />• Mortar joints are tooled <br />• Weeps without through -wall flashing is evident at lintels <br />• Sealants at windows, doors and control joints in good overall condition <br />Masonry fagade overview <br />Control joint sealant in good condition <br />Page 4.5 - Reserve Component Detail <br />