<br />City of Arden Hills, MN – 25X.137753 LIFT STATION CONTROL SYSTEM <br />January 2026 PAGE 26 90 04-20 <br />©2026 Design Tree Engineering, Inc All Rights Reserved <br /> GFCI RECEPTACLE <br />A. GFCI receptacle near the bottom of the enclosure mounted on the back panel. Provide on inner door if <br />shown as such on the Contract Documents. <br />B. Receptacle shall be fed by a 10A min. circuit breaker powered from the control panel power circuit, <br />ahead of the UPS. <br />C. Specification grade, 3-wire grounding type, NEMA 5-20R. <br />D. Side wired. <br />E. Rated 20 amperes, 125 volts. <br />F. LED trip indicator. <br />G. Approved Manufacturers: <br />1. Cooper. <br />2. Hubbell. <br />3. Leviton. <br />4. Pass & Seymour. <br /> CONTROL POWER BACKUP BATTERY <br />A. Provide an AGM battery located inside of the control panel for control power backup in case of loss of <br />normal power. <br /> CONTROL PANEL LIGHT KIT <br />A. Integrated automatic switch, spring-loaded, turning on when door is opened and shutting off when <br />door is closed. <br />B. 120VAC, LED. <br />C. Provide one light for each compartment of the control panel. <br /> IDENTIFICATION <br />A. Devices on the door exterior shall be identified with engraved phenolic tags which are engraved with <br />white lettering on a black background and are attached with stainless steel screws. <br />B. Devices on interior doors shall be identified with engraved phenolic tags which are engraved with white <br />lettering on a black background and are attached with stainless steel screws. <br />C. Devices mounted inside the panel shall be identified with embossed labels with adhesive backs as <br />shown on the Contractor submitted wiring diagrams. Labels shall be on the mounting panel, near the <br />device. <br /> TERMINAL BLOCKS <br />A. DIN rail mounted, touch safe, modular type. <br />B. 600V RMS, 30 amps minimum or higher amp rating as required for application. <br />C. Connector metal body material: Copper alloy, min 85% copper with nickel or tin plating. <br />D. Terminal screw material: Bronze with tin plating. <br />E. Screw terminals on both side only. No other types shall be allowed. <br />F. Shall terminate wires without additional preparation: i.e. tinning of wire ends, application of ferrules, <br />etc. <br />G. The insulation housing shall have primary entry funnels to facilitate insertion of wires.
The URL can be used to link to this page
Your browser does not support the video tag.