Laserfiche WebLink
<br />Pedestrian Orientated Lighting: The current TRC does not specifically require the <br />installation of pedestrian oriented lighting but does establish design and spacing <br />requirements if it is installed. The proposed TRC amendment language references the <br />MnDOT Roadway Lighting Design Manual which also provides guidance for pedestrian- <br />oriented lighting. The resultant spacing of the pedestrian-oriented lights would be <br />approximately 50-ft. Appendix C is attached to this memo providing photometric layouts for <br />the potential pedestrian-oriented lights meeting MnDOT Roadway Lighting Design Manual <br />standards. The table below summarizes the design criteria and performance of the lighting <br />shown in Appendix C. <br /> Minimum Avg <br />Illuminance <br />(Fc) <br />Design Avg <br />Illuminance <br />(Fc) <br />Minimum <br />Uniformity <br />(Avg/Min) <br />Design <br />Uniformity <br />(Avg/Min) <br />Pedestrian Light Spacing (MnDOT) 2.0 2.15-2.16 3.0 1.43-1.44 <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />