<br />, '., <br /> <br />e <br /> <br />e <br /> <br />- <br /> <br />.' <br /> <br />If you elect to not have Ehresmann Engineering complete this <br />final inspection, Ehresmann Engineering can not be held <br />responsible for installation of antennas, antenna mounts, <br />feedlines and/or modification materials in accordance with <br />our analysis and specification. <br /> <br />We would like to point out the fact that we considered this <br />tower to be in near new condition when completing our struc- <br />tural analysis. No allowance was made for missing, corrod- <br />ing or deteriorating tower members. ' <br /> <br />This report is based on the following: <br /> <br />1. 'tower properly installed and maintained. <br />2. All members in good condition. <br />3. All members in place. ' <br />4. All bolts in place and properly tightened. <br />5. Weep holes on tube and pipe members open. <br />6. Tower being in plumb condition with proper guy tension <br />installed. <br />7. All tower members being properly designed, detailed, <br />fabricated, installed and maintained over the years. <br /> <br />Ehresmann Engineering Inc. is not responsible for <br />ficatiOns completed prior to or hereafter which <br />Engineering Inc. is not or was not directly <br />Modifications to include but are not limited to: <br /> <br />1. Replacing or strengthening bracing members. <br />2. Reinforcing vertical members in any manner. <br />3. Adding or relocating stabilizers. <br />4. Installing antenna mounting gates or side arms. <br />5. Changing guy sizes and related hardware. <br />6. Installing new anchors and anchor shafts. <br />7. Extending tower. <br /> <br />any modi- <br />Ehresmann <br />involved. <br /> <br />Ehresmann Engineering, Inc., hereby states that this docu- <br />ment represents the entire report and that it assumes no <br />liabilitY for any factual changes that may occur after ,the <br />date of this report. All representations and recom- <br />mendations and conclusions are based upon the information <br />contained and set forth herein. If you are aware of any <br />information which is contrary to that which is contained <br />herein, or you are aware of any defects arising from the <br />original design, material, fabrication and erection defi- <br />ciencies, you should disregard this report and immediately <br />contact Ehresmann Engineering Inc. Ehresmann Engineering <br />Inc.1 disclaims all liability for any representation, recom- <br />mendation or conclusion not expressly stated herein. <br /> <br />6 <br />