Laserfiche WebLink
<br />", .... <br /> <br />. <br /> <br />. <br /> <br />. <br /> <br />determine the area of steel remaining. However to be abso- <br />lutelY sure that no rusting is taking place, each tower leg <br />would have to be tested every square inch, which is not <br />economically feasible. <br /> <br />We are not implying that you do have rusting problems in the <br />subject tower, we are simply stating that we cannot guaran- <br />tee that no rusting is taking place and you should be aware <br />of this. Ourstrefis rati.t:l.s as, shown1n our analysis and in) <br />(the, resultssecfion'of thi~ reportar~bued an steel " being <br />i~~~~ew condition with no rusting or deterioration. <br /> <br />Upon request Ehresmann Engineering Inc. will visit the <br />previously described tower site and inspect tower, lines, <br />and antennas for compliance to this engineering analysis in <br />its entirety upon completion of project. Cost will be <br />quoted at time of request. <br /> <br />We would like to,point out the fact that we considered this <br />towel' to be in neatnewcClJ)dftion:when completing our' s,truc- <br />turalanalysis ..!'Io.a:,lfp.:waricewas made for missing, corrod- <br />ing6'# deteriorating tower members. <br /> <br />This report is based on the following: <br /> <br />1. Tower properly installed and maintained. <br />2. All members in good condition. <br />3. All members in place. <br />4. All bolts in place and properly tightened. <br />5. Weep holes on tube and pipe members open. <br />6. Tower being in plumb condition with proper guy tension <br />installed. <br />7. All tower members being properlY designed, detailed, <br />fabricated, installed and maintained over the years. <br /> <br />Ehresmann Engineering Inc. is not responsible for <br />fications completed prior to or hereafter which <br />Engineering Inc. is not or was not directly <br />Modifications to include but are not limited to: <br /> <br />any modi- <br />Ehresmann <br />involved. <br /> <br />1. Replacing or strengthening bracing members. <br />2. Reinforcing vertical members in any manner. <br />3. Adding or relocating stabilizers. <br />4. Installing antenna mounting gates or side arms. <br />5. Changing guy sizes and related hardware. <br />6. Installing new anchors and anchor shafts. <br />7. Extending tower. <br /> <br />Ehresmann Engineering, Inc., hereby states that this docu- <br />ment represents the entire report and that it assumes no <br /> <br />4 <br />