My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
CCP 01-23-2006
ArdenHills
>
Administration
>
City Council
>
City Council Packets
>
2000-2009
>
2006
>
CCP 01-23-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/8/2007 1:21:14 PM
Creation date
11/14/2006 4:41:45 PM
Metadata
Fields
Template:
General (2)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
161
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br /> <br />DISCUSSION OF OBSERV A nONS <br /> <br />A, Site Location and Condition <br /> <br />The immediate tank site was not fenced to protect the tank from vandalism or <br />possible contamination of stored water. Although the tank's design somewhat limits <br />access to the roof, a cbain-link fence surrounding the site should be considered if <br />additional security is desired. All future site maintenance should be directed away from <br />the tank to minimize the possibility of flying debris; such as, loose stones striking the <br />tank surface. <br /> <br />B. Foundation <br /> <br />The existing concrete foundation supporting the fluted column was inspected for <br />spalls and cracks. The foundations appeared to be in good condition with only one minor <br />surface cracks documented. The crack was located 4' to the right of the overflow pipe <br />outlet. No repair to the crack is warranted. The foundation also had one small pop-out. <br />A pop-out differs from a spall in that spalls are usually caused by corrosion of the <br />reinforcement or infrequently due to contaminants in the concrete. Pop-outs are formed <br />as the water in saturated coarse aggregate particles near the surface freezes, expands, and <br />pushes leaving a shallow pit. <br /> <br />The minimum foundation projection recommended by A WW A of 6" was not met <br />for a portion of the tank both in locations where the foundation was adjacent to concrete <br />sidewalks and adjacent to grass covered grade. The minimum projection <br />recommendation reduces the chance of accelerated corrosion due to dirt and vegetation <br />trapping moisture next to the baseplate and pedestal. <br /> <br />i <br /> <br /> <br />Photograph 23 - Pedestal Door - Note Poor Foundation Projection on Right Hand Side of <br />Photograph <br /> <br />Elevated Water Storage Tank <br />City of Arden Hills South Tank <br /> <br />22 <br />
The URL can be used to link to this page
Your browser does not support the video tag.