<br />At Hazelnut Park the following obscrvations wcrc obscrvcd. <br />. Siding on the cast sidc is badly dctcrioratcd. Sheathing beneath has bccn exposed. <br />. Roof appears to bc in an OK condition. Somc snow rcmained on roof at time of <br />inspection. Should be reinspccted. <br />. No apparent structural damagc. <br />. Somc areas of the soffit and fascia had some damage. <br />. The interior cciling had numerous holes punched through the ceiling material. <br />. The flooring material was loosc and pulling up II-om the floor. <br />.:. At a minimum the following repairs should be done. <br />. Replace siding on the east side ofthe building, <br />. Repair; replace siding as nccdcd through out the rest of the structure. <br />. Removc some ceiling material to inspcct attic area. Remove any rotted wood or <br />insulation damaged by rodents, moisture. <br />. Recover ceiling material with 1," plywood. Fasten with screws. <br />. Sccure existing flooring to floor joists and recover cntirc floor with y," treated plywood. <br /> <br />Summary <br />It should be noted that the abovc recommendations are to address immediate concerns, Thc <br />buildings are generally in poor condition and will need additional repairs in the near future. Thc <br />odor issue at Freeway Park may not be resolved with a sealant. Health issues may also be of <br />concern. <br /> <br />\\1\1 ctro- ine!. us\ardenhills\PR&PW\Rccreation\MFMOS\ W anning House inspection <br />report06,DOC <br /> <br />. <br /> <br />. <br /> <br />. <br />