My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
PCP 11-01-2006
ArdenHills
>
Administration
>
Commissions, Committees, and Boards
>
Planning Commission
>
Planning Commission Packets
>
2004-2009
>
PC Packets 2006
>
PCP 11-01-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/8/2007 1:29:23 PM
Creation date
2/16/2007 10:46:29 AM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
188
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />. CHAPTER 5 <br /> PLUMBING FACiliTIES AND <br /> FIXTURE REQUIREMENTS <br /> SECTION 501 5033 Lonltion of employee toilet fadlities. Toilet facilities <br /> GENERAL shall han~ access from within the cmpluyees' working area. <br /> The required wild fal-ilities shall be located not more than one <br /> :'01.1 Scope. Thl. pnl\ isilllls "f Ihis chapkr shall i'''lern thl' slllry abuve or below the employees' working area and the path <br /> millimum plumhin~' sy,ll'm~;. facilities aud plumbing flxlure_s "f travelt" such facilities shall not exceed a distance of 500 feet <br /> to he prllvilkd_ ( 1';2 m). Employee facilities shall either be separate facilities <br /> :'111.2 Ul'spHnsihi\it~-. Thc' ownn of the strtlcture ,hall provide llr combined employec and public facilities. <br /> and nl~tintain such plumhing fal-ilitil's alld plumbillg fixtures in EXCl'ption: Facilities that arc reqllired for employees in <br /> c(lmpliance with thes,~ relJllirements. A person shall not (In.upy 'tmage structures or kiosks. which are located in adjacent <br /> as 0\1 ner-on.upant pr pl'l mit ;llIother person to occupy any structures under the same ownership_ kase or control. shall <br /> ~-.lrlldIJl"l' Ilr prelllisl" \1 hic:h docs not Cllmply with the require- flllt exceed a travel distance of 500 feet (152 m) from the <br /> JllI~lIh "f Ihi, dlapllT employees' rcgular working area 10 Ihe facilities. <br /> 503.4 Floor surface. In olher thall dwelling units, every tllilet <br /> [PI SECTION 502 roum floor shall be maintained to be a smooth. hard. <br /> nonabsorhent surface to permit such floor to he easily kept in a <br /> REQUIRED FACILITIES dean alld sanitary c(\ndition_ <br /> 5n2.1 J)wl'lling IInits. Llny d,,-elling unit,hallc.c,ntaill ils <br /> own bathtub pr showeL lavat"IY. w;ller cll)',l't and kitchen sink <br /> which shall bl' lllainl~lillnl in a ~anilary, safe workill!,' l"l'IHIi- [PI SECTION 504 <br /> tion. The Iav~llpry ,hall bc~ pLlced in the sallle room as the watn PLUMBING SYSTEMS AND FIXTURES <br />. doS(,t or Im.alL'd in doS(' proximity tothe dOl\r kadin!,' directly 50..J.1 General. All plumbing fixtures shall be properly <br /> inlo the I '-'om in \Ihich slldl ,,-atn closet is I"cated_..\ kitchell installed and mainlailled in working order. and shall be kept <br /> sink ,hall not he used ~I' a suhstitute fllr thL' reqniled lavatory. free from obstructions. leaks and defects and be capable of per- <br /> 502..! RooJlling hOllses. :\ tleast one waler closl~t. lavatory and forming the function hlr whidl such plumbing fixtures are <br /> hathtub llr ,hml-cr sh;dl bl: ,upplied for eadl four rooming designed. All pluIIIbing fixturcs skdl he maintained in a safe, <br /> unils_ sanitary and r unci ionalcondit ion. <br /> :,02.J Holds. WIlL'Il' privalc' watlT L'loset,. hll.alcnie, and haths 504.2 Fixture clearances. Plumbing fixtures shall have ade- <br /> arl' nol pnlvidl'd_ one \valcr clo,et. one lavatory and one hath quat<: clearances for usagl' and l.leaning. <br /> tuh or shl I\\-er havini:' acee", ft Ollt a public hall\\-ay shall bl' pn>- 5H..J.3 Plumbiug Systl'JII hazards. Where it is found that a <br /> vidnl for l'adl tc~n ol"l'upant,_ plumbing sy,tem ill a sli1lCWre constitutes a hazard to the occu- <br /> 5H2...J ElllploYt,{~s' fadliti{'s. i\ minimum of one walcT doset. pants or the ,trueture hy reasoll (\f inadequate service, inade- <br /> one lavatory and <HIe drink ill!,' facility shall hl' availahll' (0 quate venting, cross L"onllection. back siphonage, improper <br /> l'lllph 'yet'S_ installation. deterioration or damage or for similar reasons, the <br /> 5112.4.1 Drinking fadlities. Drinking facilities shall hl' a ClX!c- ofticial shall require the defects to he l'onected to elimi- <br /> lIate the hellard. <br /> drillking fountain. watn c'oole-r. hllttkd I,,-ater cooler or dis- <br /> posabk cups nnt to a sink or watn dispensn_ Drinkill~' <br /> fac.ilitit'S ,hall not he !ovated in toilet fl_HllllS or bathrooms_ SECTION 505 <br /> WATER SYSTEM <br /> [PI SECTION 503 5115.1 Gl'neral. Every sink. lavatory. bathtub or shower, drink- <br /> ing fountain. water closet or other plumhing fixture shall be <br /> TOILET ROOMS properly c(IJHlected to either a public water system or to an <br /> :'11.\.1 P.-i\':Il'~-. Toilet fl\IIIllS and h;tthrooms ,halll)[Ovide pri- approved private water sy_stem. All kitchen sinks. lavatories. <br /> vacy and shall nol constitute the only pa",age\\-ay to a hall or laundry facilities. bathtubs and showl~rs shall be supplied with <br /> other span'. or to lhe c\lcrior. :\ door and interior locking hot or tempered and cold running water in accordance with the <br /> devicT shall be plovided for all COllllllllll or shared hathrOlllllS international PII/II/hing ("odc. <br /> and toile-t lOorns in a multiple dwelling. I PI 505.2 Cuntamination. The water supply shall bc main- <br /> :,OJ.2 Location. Toikt Hl(\nIS and bathrooms serving Iwtel tained frce fwm contamination. and all water inlets for plumb- <br />. ullits. womin!,' units or dormitory units or houseket'[.ling unih. ing fixtures shall be located above the flood-level rim of the <br /> shall haVc' access by traversillg nl)t more thall nile flight of slairs fixture. Shampoo basin faucets_ janitor sink faucets and other <br /> and shall haH' acc'ess from a nlllllllon hall or passageway. hose bihs or faucets to which hoses are attached and left in <br /> 2006 INTERNATIONAL PROPERTY MAINTENANCE CODE@ 15 <br /> - <br />
The URL can be used to link to this page
Your browser does not support the video tag.