<br />. CHAPTER 7 <br /> FIRE SAFETY REQUIREMENTS <br /> SECTION 701 I'ire doors and ~Ill(\ke barrier doors shall not be blocked or <br /> GENERAL ob~lruCled or otherwise made inoperable. <br /> 701.1 Scope. The pro\'isi\ln~ of Ihis chaph:r ,hall ~'O\"l'rn the <br /> minimum l"l)llditil_'n~ aJl(I standard~ for file ~aklv relatin!! 10 [F) SECTION 704 <br /> slmClures and exlniol plt"nli~e,. includin!! tire ~akly f;ll-ililies FIRE PROTECTION SYSTEMS <br /> and equipment to be provided_ 70.ot.1 Gcncral. ,\11 systems, devices and equipmcllt to dett'ct a <br /> 701.2 Rcsponsibilit)'. The owner of Ihc prcmist>, ,hall pro\ ide lire. aClUate an alarm. or suppress or conlrol a fire or any com- <br /> and maintain such fire ~akty fat'ililies and l>qnipml'nl inl"lllll- bi nat ion thereol shall be maintained in an (lperahle condition al <br /> pliancc with Ihesc requin'menh_ ,\ pnson ,hall not uccnpy as all tirnes in accordance with the llllemlltiul1111 Fire Code. <br /> owner-occupant (Ir pc'rmil anolhe! per,on to on'upy any pre-- 70.ot.2 Smoke alarms. Single or lIIultiple-~tati(ln ~lIIoke alarms <br /> mises that du filiI comply with the requiremellls of thi~ dl<lllll'r_ <br /> ~hall be installed and maintained in Gwups R-~. R-3. R-4 and <br /> in dwellings not regulated in Group R occupancies. regardless <br /> [F] SECTION 702 of occupant load at all of the following localions: <br /> MEANS OF EGRESS I. On Ihe ceiling or wall oUI~ide of eat.h separate sleeping <br /> 702.1 Gcm'ral. i\ safe. continllou~ and llllllb~trul"l('d palh of area in the immediate vicillity of hcdrooms. <br /> travel shall hcpro\ided frolll any poilll ill a bnildint or struOllre 2_ In t~ach room used for sleeping purpOSt~S, <br /> to the puhlic way. t\kans 01 q'It'SS shall comply with thl'IIIII-r , ln each story within a dwelling unit. including basements <br /> 11111iolllll Fia: C"tle. and ct'lIars bul not including nawl spaces and uninhabit- <br /> 702.2 Ables. The reljui! t'd widlh 01 ai~les in at'cordalll'(~ \\ ith able allies_ In dwellings or dwelling units with split lev- <br />. the IlIlemati(///(/I Fin- Cod,. shall ht' ulHlh,trut"\cd_ els and without an intervening door hetween the adjacent <br /> 702.3 I ,ocked doors. .-\ II nlt'am pi egre,~ dlH.lh ,hall be rt'adi Iy levels. a smoke alarm inSlalled on the upper level shall <br /> openable from Ihe ,ide Irom whidl t'gress is t\l bt' made witlHIUt ~ulfice for the adjacenl lower level provided that the <br /> the need for keys. ,pe,.ial kfHlwledtl' or dfprL except where the lower level is less than one full story helow the upper <br /> door hanlwan~ conforms II I Ih;11 pl'rIllIlICd by the 11111 "1"111 II i"1I111 level. <br /> Huildill~ (."d<,_ Sillgk or IIlUiiipk-slaiillll smoke alarms shail be insiailcd in <br /> 702A Emergency escapc openings. Rt'quirl'd l>mCr!~l'ncy nlher groups in aecordalll"e with the Il1terFwt;mwl Fire Cude. <br /> escapc opt'nints shall he Illaintaincd in aCt'(lldancc \lilh Ihe 711.ot31'1mel' source. In Group R lltTupancies and in dwellings <br /> code in effect at thl~ lime IIf cOllslmclion. and the fllllowill~. Iwl nTulalt:d as Grpup R OtTupalH:ies, sintle-slation smoke <br /> Required elllertenc)' e'cal'e and rescue openings shall hl' I)pe;. alarms shall receive tht~ir primary power Irom the building wir- <br /> ationallrpm Ihe in,idl' of Ihe room wilhout Ihe u~e of I\l'Ys Ilr ing providcd that such wiring is served from a commercial <br /> tools. liars. trille~. trales IIr ~imilar de\-it:es are permitted to he ,ourt.c and shall he equipped with a ballery hackup. Smoke <br /> placed on'r emngency escape and reSl-ue ,-,pening~ pn ,vided alarms shall cmit a signal when the batteries are low. Wiring <br /> the minimum nel t-kar openint ~ize complie~ wilh Iht' CI Ide Ihat ,hall bt' pnmanenl and wilh\lut a disconnecting swilch other <br /> was in effect allhe limc of l"(lnslrut"\ion and such devices shall than a~ required f\lr ovelTurrent pn>ttTlion_ <br /> be releasahle or rt~nlllvahk from tl1l' inside withllut the u'c IIf a Exn'ption: Smoke alarms are permitted to he solely battery <br /> key, 1001 or force greater thanlhat which is n~quired fllr lIormal operated in buildings wherc no construl'tion is laking place, <br /> operation pi the e'Glllt' and re~CUt' opellint_ huildings that are nOI served from a commercial power <br /> source and ill exisling areas 01 buildings undergoiug aller- <br /> [F) SECTION 703 ations or repairs Ihat do nOI resull in the removal of interior <br /> wall or ceiling finishes exposing Ihe structure. unless there <br /> FIRE-RESISTANCE RATINGS i~ an altic. crawl ~pal"e or ha,ement availahle which could <br /> 7113.1 Fire-rcsistant'e-rated aSSl'mblies. The required fire- pwvide access for building wiling wilhout the removal of <br /> rcsistance rating 01 lilt"- re,islallt"e- ratt'll walls. fire SlOps. shaft interior finishes. <br /> enclo~ures. partitions and Il,,()r~ shall he mainwined_ 70.otA Inh'n'om){~l"IiCJn. Where more Ihan one smoke alarm is <br /> 703.2 Opcning pmtel"lives. Required opening protl'l,ti\t'~ required II.> he installed within an individual dwelling unit in <br /> shall be maintained in an ppnati\'e conditi(lIl_ ,\11 fire and (Inlup R-2. R- _,. R-.t and in dwellings not regulated as Group R <br /> snlllkt'stop doors _,hall he lIIainlained in operahlt: l'l.Hldilion_ occupancies. the smokc alarms shall be inlt'r('(lnnected in such <br />. <br /> 2006 INTERNATIONAL PROPERTY MAINTENANCE CODE~) 19 <br />
The URL can be used to link to this page
Your browser does not support the video tag.