Laserfiche WebLink
Ordinance 2010-008 <br />the stages of the one hundred (100) year or regional flood but only after <br />the City has received an appropriate plan which assures the removal of <br />the materials from the floodway based upon the flood warning time <br />available. The Conditional Use Permit shall be title registered with the <br />property in the Office of the County Recorder. <br />E. Accessory Structures. <br />1. Accessory structures shall not be designed for human habitation. <br />2. Accessory structures, if permitted, shall be constructed and placed on <br />the building site so as to offer the minimum obstruction to the flow of <br />flood waters. <br />a. whenever possible, structures shall be constructed with the <br />longitudinal axis parallel to the direction of flood flow; and <br />b. So far as practicable, structures shall be placed approximately on <br />the same flood flow lines as those of adjoining structures. <br />3. Accessory structures shall be elevated or fill or structurally dry flood <br />proofed in accordance with the FP-1 or FP-2 flood proofing <br />classifications in the State Building Code. As an alternative, an accessory <br />structure may be flood proofed to the FP-3 or FP-4 flood proofing <br />classification in the State Building Code provided the accessory structure <br />constitutes a minimal investment, does not exceed five hundred (500) <br />square feet in size at its largest projections, and for a detached garage, the <br />detached garage shall be used solely for parking of vehicles and limited <br />storage. All flood proofed accessory structures shall meet the following <br />additional standards: <br />a. The structure shall be adequately anchored to prevent flotation, <br />collapse or lateral movement of the structure and shall be designed to <br />equalize hydrostatic flood forces on exterior walls; and <br />b. Any mechanical and utility equipment in a structure shall be <br />elevated to or above the Regulatory Flood Protection Elevation or <br />properly flood proofed. <br />c. To allow for the equalization of hydrostatic pressure, there must <br />be a minimum of two "automatic" openings in the outside walls of <br />the structure having a total net area of not less than one square inch <br />for every square foot of enclosed area subject to flooding. There must <br />be openings on at least two sides of the structure and the bottom of all <br />openings must be no higher than one foot above the lowest adjacent <br />grade to the structure. Using human intervention to open a garage <br />