Loading...
HomeMy WebLinkAbout11-06-19 PCAPPROVAL OF THE AGENDA APPROVAL OF MINUTES October 9th, 2019 Planning Commission Regular Meeting 10 -09 -19 PC MINUTES.PDF PLANNING CASES Planning Case 19 -010 –Valentine Hills Elementary School –Site Plan Review, Amended Conditional Use Permit (Public Hearing Required) MEMO.PDF ATTACHMENT A.PDF ATTACHMENT B.PDF ATTACHMENT C.PDF Planning Case 19 -015 –3244 Sandeen Road –Variance (No Public Hearing Required) MEMO.PDF ATTACHMENT A.PDF ATTACHMENT B.PDF ATTACHMENT C.PDF ATTACHMENT D.PDF ATTACHMENT E.PDF UNFINISHED AND NEW BUSINESS COMMENTS AND REPORTS Report From The City Council Planning Commission Comments ADJOURNMENT ADJOURN A quorum of the City Council may be present at this meeting. Chair: Nick Gehrig Commissioners: Steven Jones James Lambeth Subbaya Subramanian Paul Vijums Jonathan Wicklund Clayton Zimmerman Council Liaison: Dave McClung Planning Commission November 9, 2019 6:30 p.m. City Hall Address: 1245 W Highway 96 Arden Hills MN 55112 Phone: 651 -792 -7800 Website : www.cityofardenhills.org City Vision Arden Hills is a strong community that values its unique environmental setting, strong residential neighborhoods, vital business community, well -maintained infrastructure, fiscal soundness, and our long -standing tradition as a desirable City in which to live, work, and play. Agenda CALL TO ORDER 1. 2. 2.A. Documents: 3. 3.A. Documents: 3.B. Documents: 4. 5. 5.A. 5.B. 6. APPROVAL OF THE AGENDAAPPROVAL OF MINUTESOctober 9th, 2019 Planning Commission Regular Meeting10-09 -19 PC MINUTES.PDFPLANNING CASESPlanning Case 19 -010 –Valentine Hills Elementary School –Site Plan Review, Amended Conditional Use Permit (Public Hearing Required)MEMO.PDFATTACHMENT A.PDFATTACHMENT B.PDFATTACHMENT C.PDFPlanning Case 19 -015 –3244 Sandeen Road –Variance (No Public Hearing Required)MEMO.PDF ATTACHMENT A.PDF ATTACHMENT B.PDF ATTACHMENT C.PDF ATTACHMENT D.PDF ATTACHMENT E.PDF UNFINISHED AND NEW BUSINESS COMMENTS AND REPORTS Report From The City Council Planning Commission Comments ADJOURNMENT ADJOURN A quorum of the City Council may be present at this meeting. Chair:Nick GehrigCommissioners:Steven JonesJames LambethSubbaya SubramanianPaul VijumsJonathan WicklundClayton Zimmerman Council Liaison:Dave McClung Planning Commission November 9, 2019 6:30 p.m. City Hall Address:1245 W Highway 96 Arden Hills MN 55112 Phone:651 -792 -7800 Website : www.cityofardenhills.org City VisionArden Hills is a strong community that values its unique environmental setting, strong residential neighborhoods, vital business community, well -maintained infrastructure, fiscal soundness, and our long -standing tradition as a desirable City in which to live, work, and play. AgendaCALL TO ORDER1.2.2.A.Documents:3.3.A.Documents:3.B.Documents: 4. 5. 5.A. 5.B. 6. Approved: November 6, 2019 CITY OF ARDEN HILLS, MINNESOTA PLANNING COMMISSION WEDNESDAY, OCTOBER 9, 2019 6:30 P.M. - ARDEN HILLS CITY HALL CALL TO ORDER/ROLL CALL Pursuant to due call and notice thereof, Chair Nick Gehrig called to order the regular Planning Commission meeting at 6:30 p.m. ROLL CALL Present were: Chair Nick Gehrig, Commissioners Steven Jones, James Lambeth, Subbaya Subramanian, Paul Vijums, Jonathan Wicklund, and Clayton Zimmerman. Absent: None. Also present were: Community Development Manager/City Planner Mike Mrosla, Planning Consultant Jane Kansier, and Councilmember Dave McClung. APPROVAL OF AGENDA – OCTOBER 9, 2019 Chair Gehrig stated the agenda will stand as published. APPROVAL OF MINUTES September 4, 2019 – Planning Commission Regular Meeting Commissioner Zimmerman moved, seconded by Commissioner Wicklund, to approve the September 4, 2019, Planning Commission Regular Meeting as presented. The motion carried unanimously (7-0). PLANNING CASES A. Planning Case 19-014; Mounds View High School – Interim Use Permit – Public Hearing Planning Consultant Kansier stated Mounds View Public Schools has applied for an Interim Use Permit (IUP) to allow the existing building on the property at 1901 Lake Valentine Road to be temporarily used as the weight room/fitness center for Mounds View High School. This ARDEN HILLS PLANNING COMMISSION – October 9, 2019 2 property is zoned R-1, Single Family Residential and is part of the Mounds View High School Planned Unit Development. Planning Consultant Kansier reported the City Council approved a Planned Unit Development for Mounds View High School in May 2019. The approved PUD allowed for additions to the existing high school building and allowed multiple lots to be treated as a single development. Planning Consultant Kansier explained when the original PUD application was submitted, the Applicant intended to use the existing building at 1901 Lake Valentine Road for cold storage. A more intensive use of the building may be proposed at a later date. As a result, the City Council included the following as a condition of approval of the PUD: Any use of the existing building on the on PID 21302334005 other than cold storage will require an amendment to the approved PUD. The existing structure shall comply with City Code Chapter 14 and any other use of the building shall meet all applicable codes. Planning Consultant Kansier indicated when construction of the high school improvements began, the School District realized they did not have an interim location for the weight room/fitness center. This room is generally used for fitness and weight training as part of the overall health and wellness curriculum. The school officials looked for a temporary location and decided to use the existing building at 1901 Lake Valentine Road. The School District worked with the Fire Marshall and building inspections staff to bring the space into conformance with building and life safety codes. During that time school and planning staff met to discuss approval options. As a result, the school district has submitted this application for an IUP. A temporary certificate of occupancy pending Planning Commission and City Council approval of the IUP. Planning Consultant Kansier stated Interim Use Permits are intended to allow uses that may be appropriate in a zoning district on a temporary basis, provided specific conditions are met. The IUP process is dictated by Section 1355.04, Subd. 7, of the City Code. The purpose and intent of an IUP was discussed with the Commission. Planning Consultant Kansier stated at this time, the applicant is applying for an IUP to allow the use of the existing building at 1901 Lake Valentine Road for a weight room/fitness center until October 1, 2020. The weight room is approximately 40’ by 80’ and is located in the southwest corner of the existing building. The remaining portion of the building is used for storage. Fire-rated sheetrock walls have been constructed around the weight room to meet building and fire code requirements. The room functions as part of Mounds View High School, so no additional parking spaces are required. No external changes to the building are proposed. Planning Consultant Kansier reported the applicant has provided a general statement of the future use of the building once the IUP has expired. This use includes storage of vehicles and equipment. The School District will review and prioritize upgrades to the building and grounds as part of their long-term facility planning process. Planning Consultant Kansier reviewed the surrounding area, the Plan Evaluation and provided the Findings of Fact for review: ARDEN HILLS PLANNING COMMISSION – October 9, 2019 3 1. The use is allowed as an interim use in the underlying zoning district and conforms to the zoning regulations; This site is a PUD with an underlying zoning of R-1. Schools are permitted as a CUP or a PUD in the R-1 district. The proposed interim use is an extension of the existing school. 2. Permission of the interim use will not impose additional costs on the public if it is necessary for the public to take the property in the future; There are no additional costs to the public. The use will be conducted in an existing building, and minimal improvements have been made. Further, there are no plans for public improvements in this area. 3. The use will not adversely impact nearby properties through nuisance, noise, dust, glare, or unsightliness, and will not otherwise adversely impact the health, safety, and welfare of the community; The use of this building for this purpose will not create a nuisance or impact the health, safety and welfare of the community. The proposed use is less intensive than the previous use as a bus garage. 4. The use will not adversely impact traffic and parking; The facility will only be used by students at Mounds View High School during the hours of approximately 7:00 AM to 5:00 PM. No additional parking will be required. 5. The use will not adversely impact implementation of future amendment to the City's Comprehensive Plan; This site will be designated for Public & Institutional uses. This use is consistent with that designation. 6. The date or event that will terminate the use is identified with certainty; The Applicant has indicated this use will be discontinued upon completion of the weight room/fitness center in the high school building, or no later than October 1, 2020. 7. The applicant has signed a consent agreement agreeing that the applicant, owner, operator, tenant, and/or user has no entitlement to an extension of the Interim Use Permit; Upon approval of the IUP, the applicant will be asked to sign a consent agreement. 8. The user agrees to all conditions that the City Council deems appropriate for permission of the use including the requirement of appropriate financial surety to cover the cost of removing the interim use and any interim structures upon expiration of the interim use permit; Upon approval of the IUP, the applicant will be asked to sign a consent agreement. 9. There are no delinquent property taxes, special assessments, interest, or City utility fees due upon the subject parcel; There are no property taxes or other fees owed. 10. The term of the interim use does not exceed three (3) years; ARDEN HILLS PLANNING COMMISSION – October 9, 2019 4 The interim use will be slightly less than one year from the date of approval. After October 1, 2020, the use of the building is intended for cold storage and vehicle parking. 11. The property has not been a recipient of a previous interim use permit. A property that has received an interim use permit for an interim use listed in 1320.05, Land Use Chart, shall not be eligible for another interim use permit of the same use; No previous interim use permits have been issued on this site. 12. Any special requirements in Section 1320 for a particular interim use are met. Section 1320 lists no special requirements for this use. Planning Consultant Kansier stated based on the submitted plans and findings of fact, staff recommends approval of Planning Case 19-014 for an Interim Use Permit at 1901 Lake Valentine Road be subject to the following conditions: 1. The project shall be completed in accordance with the plans submitted as amended by the conditions of approval. Any significant changes to the plans, as determined by the City Planner, shall require review and approval by the Planning Commission and City Council. 2. The area used for the weight room/fitness facility shall not exceed 3,200 square feet and shall be confined to the location shown on the building permit and plans on file at the City. 3. The facility shall be used for school classroom use only and shall not be open to the general public. 4. Hours of operation for this use are limited to 7:00 AM to 5:00 PM on Monday through Friday. No after-hours use is permitted. 5. No vehicles of any kind shall be parked or stored within the building while the IUP is in effect. 6. The Interim Use Permit shall be in effect until 5:00 PM on October 1, 2020. 7. No extension of the IUP shall be permitted without City Council approval. The Applicant is not entitled to an extension of this permit. 8. All weight room and classroom equipment must be removed from the facility by 5:00 PM on Friday, October 2, 2020. 9. Once this IUP expires, any use of the existing building at 1901 Lake Valentine Road (PID 21302334005) other than cold storage will require an amendment to the approved PUD. Any changes made to the building for the storage use will require a building permit. 10. Any violation of the conditions of this Interim Use Permit may result in revocation of the permit. Planning Consultant Kansier reviewed the options available to the Planning Commission on this matter: 1. Recommend Approval with Conditions 2. Recommend Approval as Submitted. 3. Recommend Denial 4. Table Chair Gehrig opened the public hearing at 6:44 p.m. ARDEN HILLS PLANNING COMMISSION – October 9, 2019 5 Chair Gehrig invited anyone for or against the application to come forward and make comment. There being no comment Chair Gehrig closed the public hearing at 6:44 p.m. Chair Gehrig opened the floor to Commissioner comments. Commissioner Zimmerman asked if the building had sprinklers or fire proof doors. Planning Consultant Kansier reported the fire and building codes do not require the building to have sprinklers. Community Development Manager/City Planner Mrosla explained the Fire Marshall had reviewed and approved the proposed plans. He noted additional alarm systems were added to the building for safety purposes. He commented further on the doors that served the building. Commissioner Zimmerman stated he was concerned students would be in this building and wanted to be assured it was safe. Planning Consultant Kansier commented staff was also concerned about this and noted the Building Official and Fire Marshall had taken a special look at this building. She indicated fire rated walls had been installed and all doors opened outward to allow students to exit the building quickly. Commissioner Wicklund asked if a Phase I or Phase II environmental assessment was completed on this building by the school district. Planning Consultant Kansier deferred this question to the applicant. Commissioner Wicklund questioned if the City would be responsible for any harmful toxins that could impact staff or students. Planning Consultant Kansier reported the City would not be responsible. Commissioner Wicklund inquired if the school district asked for the 7:00 a.m. to 5:00 p.m. time period. Planning Consultant Kansier stated the school asked for an 8:30 a.m. to 4:30 p.m. time frame and staff extended this timeframe slightly. Commissioner Vijums believed the school was making a logical choice moving the weight room to a new space and he supported the requested Interim Use Permit. Commissioner Jones asked if the building would have to be brought up to code to meet heating and cooling requirements. Planning Consultant Kansier stated it was her understanding the applicant would be bringing the building up to code to meet all applicable building requirements. ARDEN HILLS PLANNING COMMISSION – October 9, 2019 6 Mike Schwartz, Mounds View Public Schools, explained at this time the space was being used for four classrooms. He noted the space was up to code with respect to building and fire code. He indicated a plywood and rubber floor would be installed in the building. Commissioner Lambeth questioned if the space was already being used as a weight room by the school district. Mr. Schwartz reported the school district was not aware of the fact it needed to go through this process. He stated he has since been working with staff, the Lake Johanna Fire Department and building officials. Commissioner Lambeth inquired if the building was currently in use and if this impacted the IUP. Mr. Schwartz reported the building was being used. Planning Consultant Kansier stated instances like this happen all the time and staff proceeds as if the use was not in place. She explained the City was not obligated to take any specific action regarding this IUP. Commissioner Lambeth discussed the size of the weight room (3,200 square feet) and asked if the area being used was being driven by the dimensions of the building. Community Development Manager/City Planner Mrosla stated this was the case and noted it was the City’s intent to not allow for any expansion of the weight room/fitness space. Commissioner Subramanian commented on the high level of traffic that occurs in the morning surrounding the school. He questioned if a traffic study had been completed by the school. Community Development Manager/City Planner Mrosla explained a traffic study was being completed by WSB. He noted the traffic study would focus on AM and PM peaks. He reported the students using the weight room were using the space during non-peak hours. Mr. Schwartz discussed the timeline for the students using the weight room prior to or after school. He commented traffic patterns in and out of the school were smoothing out. Commissioner Subramanian asked what would happen if toxins were found in the building, given the fact the building was already in use. Community Development Manager/City Planner Mrosla stated from a life safety perspective the building already meets building code requirements. He indicated the school district was proposing the weight room as a temporary or interim use. Commissioner Wicklund commented on the type of work that would be conducted if a Phase I or Phase II Environmental Study was completed on the building. Chair Gehrig asked if the suggested dates within the permit were identified by staff. ARDEN HILLS PLANNING COMMISSION – October 9, 2019 7 Mr. Schwartz explained the school plans to be out of this building prior to August of 2020. Commissioner Wicklund questioned what the normal practice was for operations that occur prior to receiving proper permits from the City. Planning Consultant Kansier discussed her experience with this type of situation. Community Development Manager/City Planner Mrosla reiterated the fact that the building had been inspected by the Fire Marshall and Building Official and the site passed inspection. Commissioner Jones expressed concern with the fact the building may not be properly ventilated given the fact the space would be used for an intense athletic use. Planning Consultant Kansier reported the applicant was required to receive building and fire code permits. She noted the space has been inspected by the building official and a temporary certificate of occupancy was approved. Chair Gehrig thanked staff for answering all of the questions from the Commission. Commissioner Jones moved and Commissioner Lambeth seconded a motion to recommend approval of Planning Case 19-014 for an Interim Use Permit at 1901 Lake Valentine Road, based on the findings of fact and submitted plans, as amended by the ten (10) conditions in the October 9, 2019, Report to the Planning Commission. The motion carried unanimously (7-0). B. Planning Case 19-012; Presbyterian Homes – Site Plan Review – No Public Hearing Required Planning Consultant Kansier stated Patrick McChesney of Presbyterian Homes (“The Applicant”) is requesting site plan review for a proposed project on 3200 Lake Johanna Blvd (‘The Subject Property”) to install an Emergency Power Supply System (EPSS) on site. Planning Consultant Kansier explained Johanna Shores is multi-unit senior living community located on Lake Johanna Blvd and County Road D that has been operating continuously since 1955. The site is comprised of 410 units in a mix of independent senior apartments, assisted living units, memory care units, hospice units, and McKnight Care Center. The 22-acre parcel was approved for a Planned Unit Development (PUD) in 2010 under Resolution 10-067 to allow for greater flexibility with height and density requirements to accommodate the 410 units on the site. The Applicant is requesting a site plan review for the installation of a proposed EPSS to be located on a concrete pad outside the physical plant on the north side of the property. Planning Consultant Kansier reported the Applicant indicated in their application that the proposal will replace two existing EPSSs that service the Subject Property with a single diesel- fueled EPSS. The existing equipment that would be replaced are a diesel-fueled EPSS with an underground tank and a natural gas-fueled EPSS. The two existing EPSS's are located inside a room adjacent to the physical plant on the rear on the building as shown on the image below. The ARDEN HILLS PLANNING COMMISSION – October 9, 2019 8 proposed replacement EPSS would be located outside the physical plant on the north side of the campus adjacent to Sandeen Road. Planning Consultant Kansier commented under the state licensure requirements of a nursing home, a nursing home “shall be kept in a continuous state of good repair and operation with regard to the health, comfort, safety and wellbeing of the occupants in accordance with an established routine maintenance and repair program” including an emergency electrical service that “shall be operated and tested at frequent intervals”. (Chapter 4660.7800 Plant Operation and maintenance for Existing and New). The two existing EPSS systems are reportedly over 50 years old and are nearing the end of their serviceable lifetime. The replacement EPSS proposed will have a greater capacity than the combined total for the two existing EPSSs. Planning Consultant Kansier reviewed the surrounding area, the Plan Evaluation and provided the Findings of Fact for review: 1. The Applicant is requesting site plan review for a proposed project at Johanna Shores Senior Living Facilities to install an Emergency Power Supply System (EPSS) on site. 2. The two existing EPSS systems are reportedly over 50 years old and are nearing the end of their serviceable lifetime. The replacement EPSS proposed will have a greater capacity than the combined total for the two existing EPSSs. 3. Under state licensure requirements, a nursing home shall be kept in a continuous state of good repair and operation including an emergency electrical service that shall be operated and tested at frequent intervals. 4. The Applicant indicated to staff that emergency testing of the EPSS would be confined to no more than one hour a month during day time hours. 5. The Subject Property is located within a PUD guided by the R-4 Zoning District and the location of the proposed EPSS is 60 feet from the nearest property line to the north and approximately 12 feet from the nearest structure, which meets all setback requirements for the Subject Property. 6. The concrete pad will be located further to the east in a zone designated with minimal risk of flooding. 7. Mechanical equipment will be screened with a chain link fence with beige fence weave privacy slats, installed on all 4 sides of the concrete pad to a height of 11 ½ feet above grade to conceal the EPSS, which is 139" high. 8. To help attenuate noise an air intake silencer will be installed on the equipment by the manufacturer to reduce any noise with sound absorbing insulation. Staff noted the Planning Commission must make a finding as to whether or not the proposed application would adversely affect the surrounding neighborhood or the community as a whole based on the aforementioned factors. Planning Consultant Kansier stated staff recommends approval of the Site Plan Review with the following conditions: 1. The project shall be completed in accordance with the plans submitted as amended by the conditions of approval. Any significant changes to these plans, as determined by the City Planner, shall require review and approval by the Planning Commission and City Council. ARDEN HILLS PLANNING COMMISSION – October 9, 2019 9 2. All proposed fencing shall be black vinyl-coated chain link. 3. The structure shall conform to all other regulations in the City Code. 4. The Applicant shall work with the City staff to mitigate any noise concerns if complaints are received. 5. Monthly equipment testing shall occur weekdays between the hours of 8:00 a.m. and 5:00 p.m. Planning Consultant Kansier reviewed the options available to the Planning Commission on this matter: 1. Recommend Approval with Conditions 2. Recommend Approval as Submitted. 3. Recommend Denial 4. Table Chair Gehrig opened the floor to Commissioner comments. Commissioner Subramanian indicated noise was a concern within this request. He asked how much noise would be generated by the equipment being installed. Community Development Manager/City Planner Mrosla stated the noise from the new equipment would be less impactful than the existing equipment on site. It was staffs understanding the noise would be reduced from 92 decibels to 60 decibels at 60 feet from the property line. Commissioner Subramanian questioned what would happen to the old generator. Pat Jesney, Presbyterian Homes representative, reported the existing generator would be dismantled and removed from the space, along with the old storage tank. He reported the space would be utilized for storage. Commissioner Lambeth inquired if black slats were required in the chain link fence. Community Development Manager/City Planner Mrosla stated staff was making this recommendation to ensure the new fence matched the existing fence on the site. Commissioner Lambeth questioned if the chain link fence with slats would improve the noise situation. Community Development Manager/City Planner Mrosla anticipated this was the case. He suggested Condition 6 read: The applicant shall be required to install black slats in the chain link fence or similar material to assist with noise reduction. Commissioner Jones discussed the new generator and was pleased there would be a noise reduction. Commissioner Zimmerman agreed. ARDEN HILLS PLANNING COMMISSION – October 9, 2019 10 Commissioner Vijums asked if any landscaping was being proposed around the new generator site. Community Development Manager/City Planner Mrosla commented no additional landscaping was being proposed. Chair Gehrig was pleased the noise from the generator would be reduced and he recommended the color of the slats be determined by the applicant and that the City not get involved in this matter. Commissioner Lambeth moved and Commissioner Wicklund seconded a motion to recommend approval of Planning Case 19-012 for a Site Plan Review of 3200 Lake Johanna Blvd, based on the findings of fact and the submitted plans, as amended by the five (5) conditions in the October 9, 2019 Report to the Planning Commission. The motion carried unanimously (7-0). C. Planning Case 19-011; 1314 Cannon Avenue – Variance – No Public Hearing Required Community Development Manager/City Planner Mrosla stated Northrup Builders (the “Applicants”) have requested a variance in order to construct a four-season porch addition to the existing legal nonconforming single-family detached property at 1314 Cannon Avenue (the “Subject Property”). Community Development Manager/City Planner Mrosla reported City staff received a building permit application for a request to build a four-season porch and deck addition at the Subject Property. Upon review by Planning Staff it was determined that the request would require a variance due to existing non-conforming side yard setbacks. The existing principal structure was built in 1963 and predates the current R-1 zoning code requirements. This is the first proposed addition and this is the first request for a variance at the Subject Property. Community Development Manager/City Planner Mrosla explained the applicants have requested a variance to construct a four-season poach on an existing nonconforming property. The existing principal structure on the subject property is setback nine (9) feet from the eastern property line and has combined total setback of 19 feet. However, the R-1 zoning district requires a minimum side yard setback of 10 feet and a minimum total combined of 25 feet for residential properties. The proposed addition will be constructed to maintain the same setbacks as the existing house or nine (9) feet from the eastern property line. The proposed addition will meet all other setback and lot coverage requirements. Community Development Manager/City Planner Mrosla reviewed the surrounding area, the Plan Evaluation and the Variance Evaluation Criteria. Community Development Manager/City Planner Mrosla provided the Findings of Fact for review: ARDEN HILLS PLANNING COMMISSION – October 9, 2019 11 General Findings: 1. The property at 1314 Cannon Avenue is located in the R-1 Single Family Residential Zoning District. 2. The existing single-family residential dwelling was built prior to the existing zoning code and is a nonconforming structure because it encroaches into the required side yard setbacks on either side of the property. 3. The property owners have requested a variance in order to construct an addition that would remain flush with the side of the dwelling and would maintain the same setback as the existing structure 4. The proposed addition would meet all other minimum setback requirements for the R-1 District. 5. The proposed addition meets the minimum lot coverage requirements, maximum building height requirement, and floor area ratio requirement for the R-1 District, as indicated by the plans submitted by the Applicant. 6. The proposed development would not encroach on any flood plains, wetlands, or easements. 7. The proposed development is not expected to impact any significant trees on the property. Community Development Manager/City Planner Mrosla stated staff recommends approval of the Variance with the following conditions: 1. The project shall be completed in accordance with the plans submitted as amended by the conditions of approval. 2. Any significant changes to these plans, as determined by the City Planner, shall require review and approval by the Planning Commission and City Council. 3. A Building Permit shall be required prior to commencement of construction. 4. The structure shall conform to all other regulations in the City Code. 5. The proposed structure finish shall complement the existing structure onsite. Community Development Manager/City Planner Mrosla reviewed the options available to the Planning Commission on this matter: 1. Recommend Approval with Conditions 2. Recommend Approval as Submitted. 3. Recommend Denial 4. Table Chair Gehrig opened the floor to Commissioner comments. Commissioner Jones stated this would be a nice addition to the home and asked if the applicant had spoken to his neighbors. Chris Gross, North River Remodeling, stated his client has a letter from the next door neighbor noting the neighbor approved of the project. Commissioner Jones requested a copy of this letter be provided to staff. Chair Gehrig questioned what the finished exterior would be for the new addition. ARDEN HILLS PLANNING COMMISSION – October 9, 2019 12 Mr. Gross commented the exterior finish would match the existing siding and roofing. He noted the home had 8-inch lap siding. Chair Gehrig moved and Commissioner Zimmerman seconded a motion to recommend approval of Planning Case 19-011 for a Variance at 1314 Cannon Avenue, based on the findings of fact and the submitted plans, as amended by the five (5) conditions in the October 9, 2019 Report to the Planning Commission. The motion carried unanimously (7- 0). D. Planning Case 19-013; 1932 County Road E W - Variance – No Public Hearing Required Community Development Manager/City Planner Mrosla stated Gary and Julie Gronquist (“The Applicants”) have requested a variance in order to construct a detached garage adjacent to their existing driveway located on New Brighton Road. The subject property is located at 1932 County Road E W (“Subject Property”). Community Development Manager/City Planner Mrosla explained the Subject Property is a single-family detached dwelling with an attached garage and driveway facing County Road E W. In August 2000 a second driveway was constructed on New Brighton Road along with an associated accessory structure (shed). At the time, there were no restrictions on driveways in the R-2 District. However, on November 31, 2000, the City Council approved amended language to the City Zoning Ordinance in regards to the definition of a driveway on single family residential properties. Because the driveway on the Subject Property was built and approved prior to the change in language, the property has been legally non-conforming. Community Development Manager/City Planner Mrosla commented the Applicants are requesting a variance to build a detached garage on the Subject Property facing New Brighton Avenue. The proposed detached garage would replace the existing accessory structure (shed) onsite. The Subject Property is located on a corner lot located within the R-2 district, each yard facing a public street is considered to be a front yard with a front yard setback of 40 feet. The Applicant’s proposed detached garage would be setback 23 or encroach 17 feet into the front yard setback. Community Development Manager/City Planner Mrosla reported the area that is 40 feet from the curb facing New Brighton Avenue on the Subject Property is underneath a power line. A variance would allow the residents to build the garage closer to the curb, which would avoid relocating the power line and would preserve an existing large tree onsite. Staff reviewed the R-2 district and found numerous other accessory structures located within the 40-foot setback, including the adjacent property to the south of the subject property. Community Development Manager/City Planner Mrosla reviewed the surrounding area, the Plan Evaluation and provided the Findings of Fact for review: General Findings: 1. The property at 1932 County Road E is located in the R-2 Single Family Residential Zoning District. ARDEN HILLS PLANNING COMMISSION – October 9, 2019 13 2. The existing driveway on the property facing New Brighton Avenue is legally nonconforming because it was built prior to the ordinance amendment pertaining to driveways. 3. The property owners have requested a variance in order to construct a garage on the driveway that would encroach on the front yard setback facing New Brighton Avenue. 4. The proposed garage would meet all other minimum setback requirements for the R-2 District. 5. The proposed garage would meet the minimum lot coverage requirements, maximum building height requirement for the R-2 District, as indicated by the plans submitted by the Applicant. 6. The proposed development would not encroach on any flood plains, wetlands, or easements. 7. The proposed development is not expected to impact any significant trees on the property. Variance Findings: 8. The variance request would comply with the purpose and intent of the R-2 Zoning District and with the policies within the City’s Comprehensive Plan. 9. The proposed addition is a reasonable use of the property. 10. The Subject Property is located is a corner lot at the intersection of County Road E W and New Brighton Road. Corner lots with yards facing a public street is considered to be a front yard and any structures shall be setback of 40 feet from the property line. On non- corner lots the rear and side yard setback for accessory structures is 10 feet. However, many other properties zoned R-2 encroach upon the 40-foot setback. The Applicant is requesting to encroach 17 feet, where other properties encroach 30 or more feet into the front yard setback. 11. The proposed addition will not alter the character of the neighborhood and is consistent with the other dwellings in the neighborhood. The Applicants indicated to staff that their neighbors on surrounding properties have voiced their support and do not believe that granting a variance would negatively impact them. In addition, the Applicant work with the neighbor to the south on locating their propose structure so it would be screen by the existing garage on the adjacent property 12. The proposed variance is not based on economic consideration. 13. A solar energy system is not proposed. However, the proposed addition would not impact the ability to construct a solar energy system onsite or on an adjoining property. Community Development Manager/City Planner Mrosla stated staff recommends approval of the Variance with the following conditions: 1. The project shall be completed in accordance with the plans submitted as amended by the conditions of approval. Any significant changes to these plans, as determined by the City Planner, shall require review and approval by the Planning Commission and City Council. 2. A Building Permit shall be issued prior to commencement of construction. 3. The structure shall conform to all other regulations in the City Code. 4. The proposed accessory structure finish shall complement the existing structure onsite Community Development Manager/City Planner Mrosla reviewed the options available to the Planning Commission on this matter: ARDEN HILLS PLANNING COMMISSION – October 9, 2019 14 1. Recommend Approval with Conditions 2. Recommend Approval as Submitted. 3. Recommend Denial 4. Table Chair Gehrig opened the floor to Commissioner comments. Commissioner Subramanian asked if the tree will be removed or preserved. Community Development Manager/City Planner Mrosla explained the tree will be preserved. Commissioner Lambeth questioned when this home was built. Julie Gronquist, 1932 County Road E W, reported the home was built in 1969. Commissioner Lambeth stated he did not believe the detached garage would propose any type of inconvenience or threat to the property or surrounding properties. Commissioner Jones asked if the proposed detached garage would square up with the neighbor’s detached garage. Ms. Gronquist indicated she was trying to fit her garage behind the neighbor’s garage so that it would not be visible from her neighbor’s home. Commissioner Jones explained he fully supported the proposed request. Commissioner Vijums inquired if the applicant was requesting to encroach 13 feet or 17 feet into the setback. Community Development Manager/City Planner Mrosla stated the applicant was proposing to encroach 13 feet into the setback. Commissioner Vijums asked how many vehicles a property could have in their driveway. Community Development Manager/City Planner Mrosla explained the maximum number of cars that could be parked in a driveway was four. Commissioner Vijums questioned if the Gronquist’s could now have eight cars parked on their property given the fact they would have two driveways. Ms. Gronquist commented there was no parking allowed on New Brighton Road or County Road E and for this reason all of her guests were required to park in her driveway. Commissioner Vijums stated he could more than four vehicles being allowed on a temporary basis, but indicated he would like to see a condition for approval added that stated no more than four vehicles could be parked between the driveways, except on a temporary basis. ARDEN HILLS PLANNING COMMISSION – October 9, 2019 15 Planning Consultant Kansier stated the homeowners only have 23 feet from the property line which would only allow for two cars to be parked in this area. She anticipated that if a lot of vehicles were being parked on this property, the City would receive complaints. Commissioner Vijums indicated he did not want to see complaint calls generated and suggested a condition be added for approval. Community Development Manager/City Planner Mrosla reported a condition could be added to address this concern stating no more than two vehicles shall be parked in the driveway adjacent to New Brighton Road. Commissioner Wicklund asked how the City enforced the no more than four vehicles in a driveway requirement. Community Development Manager/City Planner Mrosla stated when the City receives a complaint the Sheriff is notified and the City inspects the property. He commented typically a notice is sent to the property owner and they are given seven days to bring the property into compliance with City Code. Chair Gehrig indicated the driveway was done before the code was passed, but the garage was not in place. He explained he was struggling with the fact the Commission was being asked to approve a brand-new garage given the fact a 20-year-old driveway was in place. Ms. Gronquist stated the driveway was installed with the understanding a garage would one day be built. She explained she has been saving to build the garage for years. She reported within City Code she was allowed to build a garage but noted the proposed location led to the variance request. Chair Gehrig thanked Ms. Gronquist for the clarification and consideration with respect to the placement of the garage. She noted she had letters from all three of her neighbors offering support to her variance request. Commissioner Subramanian questioned if the existing driveway could be eliminated. Ms. Gronquist explained the existing driveway was needed to access the garage attached to her home. Commissioner Zimmerman inquired if a fifth condition should be added for approval. Community Development Manager/City Planner Mrosla reported Condition 5 could read: No more than two (2) vehicles shall be permanently parked on the driveway adjacent to New Brighton Road. Commissioner Wicklund questioned if a condition was required to ensure the current shed was removed. Community Development Manager/City Planner Mrosla reported staff would be following upon this matter through the building permit approval process. ARDEN HILLS PLANNING COMMISSION – October 9, 2019 16 Commissioner Vijums stated he did not want to see an eyesore of numerous cars parked on the new driveway and he appreciated the fact Condition 5 was being recommended for approval. Community Development Manager/City Planner Mrosla explained that the requested variance would stay with the property and if new owners were to move into the home, only two vehicles could be parked in the driveway off of New Brighton Road. Chair Gehrig stated he was struggling with the fact the Planning Commission was proposing to make an exception to City Ordinance for this one property by restricting the number of cars that could be parked on the driveways. He believed that this issue should be addressed by the City Council and not the Planning Commission. Commissioner Wicklund moved and Commissioner Jones seconded a motion to recommend approval of Planning Case 19-013 for a Variance at 1932 County Road E West, based on the findings of fact and the submitted plans, as amended by the four (4) conditions in the October 9, 2019 Report to the Planning Commission, recommending the City Council address the number of vehicles that can be parked on properties that have two driveways. The motion carried unanimously (7-0). UNFINISHED AND NEW BUSINESS None. REPORTS A. Report from the City Council Councilmember McClung updated the Planning Commission on City Council activities. He explained the Council approved a public notification process for planning and land use applications. He stated the Council approved the sign code amendment that addressed dynamic display signs. B. Planning Commission Comments and Requests Chair Gehrig reported the Planning Commission was still seeking an alternate member. Those interested in serving were encouraged to contact City Hall for further details. C. Staff Comments Community Development Manager/City Planner Mrosla updated the Commission on the redevelopment of the old fire station. ADJOURN ARDEN HILLS PLANNING COMMISSION – October 9, 2019 17 Commissioner Zimmerman moved, seconded by Commissioner Vijums, to adjourn the October 9, 2019, Planning Commission Meeting at 9:13 p.m. The motion carried unanimously (7-0). Requested Action Mounds View Public Schools ISD #621 (“The Applicant”) is requesting a site plan review for a proposed renovation and addition to the Valentine Hills Elementary School located at 1770 County Road E2 W. The proposed project would include a renovation and 1,000 square foot expansion of the cafeteria and 9,000 square foot classroom and flex space addition. The proposed project would require an amendment to the existing Conditional Use Permit for the school to operate in an R-1 Single Family Residential zone. Background Valentine Hills Elementary School is a two-story brick building located on a 10.92 acre parcel that abuts a regional parks and trails system within a residential neighborhood adjacent to Interstate I- 35 W. The Subject Property is bounded by single-family residential homes to the south and west and by parks and recreation spaces to the north and east. The original structure was built in 1969. The property is zoned R-1, Single Family Residential District and is guided as Public or Institutional on the Land Use Plan. The use as a public elementary school was originally granted under a Conditional Use Permit when the school underwent a significant expansion in 1987 (Planning Case 87-03). The last major remodel to the property occurred in 2000 (Planning Case 00-023) for a 10,000 square foot classroom addition. As per City Code Section 1320.075 subd. 2, the Subject Property meets the special requirements for a general education school within the Single Family Residential (R-1) District. City of Arden Hills Planning Commission Meeting for November 6, 2019 P:\Planning\Planning Cases\2019\19-010 - Valentine Hills Elementary School\Memos Reports MEMORANDUM DATE: November 6, 2019 PC Agenda Item 3.A TO: Planning Commission FROM: Joe Hartmann – Associate Planner Mike Mrosla – Community Development Manager/City Planner SUBECT: Planning Case # 19-010 – Public Hearing Required Applicant: Mounds View Public Schools ISD # 621 Property Location: 1770 W County Rd E2 W Request: Site Plan Review, Amended Conditional Use Permit Approvals: 1. Site Plan Review As per the plans submitted, the Applicant is proposing two (2) building additions. The classroom addition is located on the south side of the building and is highlighted in orange in the image above. This proposed addition is located on existing greenspace onsite. The proposed addition will be two (2) stories totaling 9,000 square feet and match the height of the existing school. The proposed addition will include flex learning space, one (1) additional classroom and the relocation of existing academic programs that are currently located within three (3) existing classrooms. The three (3) existing classrooms will then be remodeled and utilized as standalone classrooms. The proposed addition on the west side of the building highlighted in yellow in the image above is a 1,000-square foot addition to the existing cafeteria that will match the height of the existing cafeteria. City of Arden Hills Planning Commission Meeting for November 6, 2019 P:\Planning\Planning Cases\2019\19-010 - Valentine Hills Elementary School\Memos Reports 2. Conditional Use Permit Amendment The Zoning Ordinance requires a Conditional Use Permit for a “general education school” in the R-1 Zoning District where the Subject Property is located under City Code Section 1320.05. Because the renovation will expand the area of the building, a Conditional Use Permit amendment is required for the Subject Property. Per City Code Section 1355.06, an application for a Conditional Use Permit amendment shall be administered in the same manner as required for a new application. Any structural alteration, enlargement or intensification change in site plan, or similar change not specially permitted, shall require City Council action and all procedures shall apply as if a new application were being requested. Plan Evaluation 1. Chapter 13, Zoning Code Review Section 1320 – District Provisions Per City Code Section 1320.075, general education schools are permitted by conditional use as long as they meet special requirements for the R-1 District, including that they “be located in a campus setting on a contiguous area of land no less than ten (10) acres in size” and that the “buildings are owned or leased by the institution or school district providing the School use.” The Subject Property is located on a 10.92 acre lot owned by the Mounds View Public Schools ISD #621. In addition, the proposed additions meet all R-1 zoning requirements for setbacks and lot coverage. Section 1325 – General Regulations Lighting Plan There are currently nine (9) exterior lights on the property facing the west and south side entrances and parking lots. Six (6) new exterior LED lamps are proposed for the site to further illuminate parking lot areas outside where the proposed additions will be constructed. According to Section 1325.05 Subd 3, “The source of illumination shall be hooded, concealed or controlled in a manner so as not to be visible from adjoining lots, streets or highways or residential areas.” The new lighting proposed will be LED fixtures that project all of their light in a downward direction to reduce light pollution. The plans submitted by the Applicant show the illumination will dissipate to roughly one (1) footcandle or less when measured from the property lines, so as not to be visible from adjacent properties. Because much of the Subject Property is adjacent to park land and some low-density single family housing, staff does not anticipate any issues with the proposed lighting. As a condition of approval, all lighting shall be downward directed shoebox style with flush lenses. Landscaping Plan The City Code Section 1325.05 subd. 1 requires that a minimum number of caliper inches of trees be provided based on the gross square footage of the building on the property. For the 11,000 square foot addition, the minimum required caliper inches is 31.7 inches. The submitted landscaping plan shows 12 new trees ranging in sizes from two to four caliper inches for a total of City of Arden Hills Planning Commission Meeting for November 6, 2019 P:\Planning\Planning Cases\2019\19-010 - Valentine Hills Elementary School\Memos Reports City of Arden Hills Planning Commission Meeting for November 6, 2019 P:\Planning\Planning Cases\2019\19-010 - Valentine Hills Elementary School\Memos Reports 35.5 caliper inches. The majority of the proposed trees are located on the west side of the property adjacent to Chatham Avenue. The Applicant is not proposing to remove any existing significant trees onsite as part of this project. Stormwater The site plan includes a stormwater plan. The Applicant is proposing to construct an underground infiltration system. The proposed system will be constructed to the east of the proposed additions and is shown on the image below. The proposed system will discharge into an existing pond located on the south side of the subject property. The Applicant is also proposing a filtration pond located adjacent to the western site access. City of Arden Hills Planning Commission Meeting for November 6, 2019 P:\Planning\Planning Cases\2019\19-010 - Valentine Hills Elementary School\Memos Reports Parking Plan Valentine Hill Elementary School currently has 38 classrooms and 75 staff persons. The existing site has 87 parking stalls. The proposed addition is not anticipated to generate additional parking demand on site because the addition will support existing academic programs and staff levels. The Applicant submitted a proof of parking plan show below. The proof of parking plan demonstrates that an additional 77 parking spaces could be made available on the south side of the lot if needed for events. Design Standards The proposed additions are utilizing the same materials as the existing building and the overall design of the proposed addition complements the existing architectural theme found on site. Brick is the primary material used on the proposed addition. To ensure the materials match the existing building, staff is requiring the Applicant to provide a materials board prior to the issuance of a building permit. City of Arden Hills Planning Commission Meeting for November 6, 2019 P:\Planning\Planning Cases\2019\19-010 - Valentine Hills Elementary School\Memos Reports Suggested Findings of Fact Staff offers the following findings of fact for consideration: 1.Valentine Hills Elementary School is a two-story brick building located on a 10.92 acre parcel within a residential area. 2. Mounds View Public Schools ISD #621 is requesting site plan review for a proposed expansion to the Valentine Hills Elementary School. 3.The use of the Subject Property as a public elementary school is permitted under a Conditional Use Permit. 4. Any expansion of the existing building would require the approval of a Conditional Use Permit Amendment. 5. The new addition will allow for a new cafeteria renovation and expansion, and four additional classrooms, as well as upgrades to the utilities and exterior lighting. 6. Zoning Code Review of the Subject Property regulations concludes that the proposed land use application conforms to City district provisions. 7.The proposed site plan will not impact parking, loading, or circulation demands since the addition is to better accommodate existing building uses and will not increase capacity or intensity of use. 8. The proposal is not expected to adversely affect the surrounding area of the community as a whole. Options and Motion Language Staff has provided the following options and motion language for this case. The Planning Commission should consider providing additional findings of fact as part of the motion to support their recommendation for approval or denial. 1.Recommend Approval with Conditions: Motion to recommend approval of Planning Case 19- 010 for a Site Plan Review and Conditional Use Permit Amendment at 1770 County Road E2, based on the findings of fact and submitted plans, subject to the following conditions: 1.All conditions of the original Conditional Use Permit shall remain in full force and effect. The Conditional Use Permit Amendment approvals shall expire one year from the date of City Council approval unless a building permit has been requested or a time extension has been granted by the City Council. 2.The project shall be completed in accordance with the plans submitted as amended by the conditions of approval. Any significant changes to the plans, as determined by the City Planner, shall require review and approval by the Planning Commission and City Council. 3. A Grading and Erosion permit shall be obtained from the city’s Engineering Division prior to commencing any grading, land disturbance or utility activities. The Applicant shall be responsible for obtaining any permits necessary from other agencies, including but not limited to, MPCA, Rice Creek Watershed District, and Ramsey County prior to the start of any site activities. 4. Heavy duty silt fence and adequate erosion control around the entire construction site shall be required and maintained by the Developer during construction to ensure that sediment and storm water does not leave the project site. 5. The Applicant shall be responsible for protecting the proposed on-site storm sewer infrastructure and components and any existing storm sewer from exposure to any and all stormwater runoff, sediments and debris during all construction activities. 6.Prior to the issuance of a Grading and Erosion permit, the Engineering Department shall review and approve final grading and utility plans in writing. 7. Prior to the issuance of a building permit, a landscape financial security of $2,500 shall be submitted. Landscape financial security shall be held for two full growing seasons. 8. All rooftop or ground mounted mechanical equipment shall be hidden from view with the same materials used on the building in accordance with City Code requirements. 9. Prior to the issuance of a building permit, the Applicant shall submit a materials board to be approved in writing by staff. 10. All light poles, including base, shall be a maximum of 25 feet in height and shall be shoebox style, downward directed, with high-pressure sodium lamps or LED and flush lenses. Other than wash or architectural lighting, attached security lighting shall be shoebox style, downward directed with flush lenses. If complaints are received the lighting adjacent to residential uses shall utilize house shields as directed by the City. In addition, any lighting under canopies (building entries) shall be recessed and use a flush lens. 2.Recommend Approval without Conditions: Motion to recommend approval of Planning Case 19-010 for a Site Plan Review and Conditional Use Permit Amendment at 1770 County Road E2 W, based on the findings of fact and submitted plans in the November 6th, 2019 Report to the Planning Commission. 3.Recommend Denial: Motion to recommend denial of Planning Case 19-010 for a Site Plan Review and Conditional Use Permit Amendment at 1770 County Road E2 W, based on the following findings of fact: the Planning Commission should identify findings to deny should specifically reference the reasons for denial and why those reasons cannot be mitigated. 4.Table: Motion to table Planning Case 19-010 for a Site Plan Review and Conditional Use Permit Amendment at 1770 County Road E2 W for the following reasons: the Planning Commission should identify a specific reason and/or information request should be included with a motion to table. Notice and Public Comments A public hearing notice for the proposed Conditional Use Permit Amendment was mailed to all properties within 1,000 feet of the Subject Property and a Public Hearing notice was published in the Pioneer Press on October 25, 2019. No public comments were received in regard to the proposal. City of Arden Hills Planning Commission Meeting for November 6, 2019 P:\Planning\Planning Cases\2019\19-010 - Valentine Hills Elementary School\Memos Reports City of Arden Hills Planning Commission Meeting for November 6, 2019 P:\Planning\Planning Cases\2019\19-010 - Valentine Hills Elementary School\Memos Reports A neighborhood meeting was held on Wednesday, October 16, 2019. Neighborhood meeting notices were mailed to all properties within 1,000 feet of the subject property. Two (2) residents were in attendance. Questions were raised about the timing of the project and potential rooftop equipment noise. Deadline for Agency Actions The City of Arden Hills received the completed application for this request on October 11, 2019. Pursuant to Minnesota State Statute, the City must act on this request by December 10, 2019 (60 days), unless the City provides the petitioner with written reasons for an additional 60 day review period. The City may, with the consent of the applicant, extend the review period beyond the initial 120 days. Attachments A.Application B.Location map C.11x17 Site Plans Disclaimer: This m ap is intended for reference purposes only and is not a legally recorded map or survey. The City of Arden Hills shall not be liable for any damages or claims that arise due to accuracy,availability, use or misuse of the inform ation herein pursuant to MNStatute 466.03 Subd 21. Location Map C o u n ty R o a d E 2 W e s tVenus Avenue Gramsie Road Chat ham AvenueSnelling Avenue North G l e n v i e w A v e n u e M ccracken LaneDellview AvenueOak Avenue Glenview Court Rolling Hills RoadChatham CourtTony Schmidt Tony Schmidt PARK ± Park and Open Space Subject Parcel §¨¦35W §¨¦694 £¤10 PT4PM1PM2CO1CO199.5587.0178.6596.5740' SETBACK10' SETBACK5' SETBACK30' SETBACK10' SETBACK119.90197.37346 SQ. FTACCESSIBLE PARKING (4 STALLS)18' X 9' STALL (TYPICAL)ACCESS DRIVEACCESS DRIVE885886887888889890LANDSCAPE ARCHITECTURE SITE PLANNING CIVIL ENGINEERINGANDERSON - JOHNSONASSOCIATES,INC.7575 GOLDEN VALLEY ROAD SUITE 200 MINNEAPOLIS. MN 55427FAX (763) 544-0531 PH (763) 544-7129DateRegistration NumberCheckDrawnDate:CommI hereby certify that this plan, specification or report was prepared byme or under my direct supervision and that I am a duly Licensedunder the laws of the State ofRevisionsDescriptionDateNumScale:NorthOVERALLDAVID A. REY11/08/194018017226711/08/19CWFDAR1" = 30'C3.11CITY RESUBMITTAL 10/8/19MINNESOTAPROFESSIONAL ENGINEERISD #621: MOUNDS VIEWPUBLIC SCHOOLS4570 VICTORIA STREET NSHOREVIEW, MN 551261770 County Road E2 WArden Hills, Minnesota 55112VALENTINE HILLSELEMENTARYSCHOOL BUILDINGADDITIONSPROJECT LOCATIONEXISTING PARKING COUNTS: 87 TOTAL STALLSPROPOSED PARKING COUNTS (81 TOTAL CAR STALLS):STAFF/VISITOR PARKING = 77 STALLSBUS PARKING = 11 STALLSADDITIONAL EVENT PARKING = 76 STALLSACCESSIBLE PARKING STALL REQUIREMENTS = 4 STALLSACCESSIBLE PARKING STALLS PROVIDED = 4 STALLSSITE STATISTICS:TOTAL SITE AREA: 10.750 ACRESEXISTING TOTAL PERVIOUS: 6.833 ACRESEXISTING TOTAL IMPERVIOUS: 3.917 ACRESBUILDINGS: 1.177 ACRESPARKING LOTS AND DRIVES: 2.233 ACRESWALKWAYS AND PATIOS: 0.507 ACRESPROPOSED TOTAL PERVIOUS: 6.783 ACRESPROPOSED TOTAL IMPERVIOUS: 3.967 ACRESBUILDINGS: 1.285 ACRESPARKING LOTS AND DRIVES: 2.227 ACRESWALKWAYS AND PATIOS: 0.455 ACRESSITE AREA BREAKDOWN: BUILDING ADDITION #2FFE = 903.90 = ARCH 100'-0"BUILDING ADDITION #1FFE = 907.90 = ARCH 104'-0"907.9907.8907.8908.0907.9ME907.4907.4907.7907.1907.4907.4907.4907.4905.0904.3904.3905.0906.0907.0897.3ME900.2ME896.4ME908.3908.4ME908.3ME907.9MEEOF 885.8886.2886.2886.8PROPOSED FILTRATION AREABOTTOM AREA = 497 SFBOTTOM ELEVATION = 885.00HWL ELEVATION = 886.03EOF ELEVATION = 885.80TREE PROTECTION FENCETREE REMOVALS885WETLANDDELINEATION LINE886887888889890885.1 ME885.4 ME890.5 ME887.5 MELANDSCAPE ARCHITECTURE SITE PLANNING CIVIL ENGINEERINGANDERSON - JOHNSONASSOCIATES,INC.7575 GOLDEN VALLEY ROAD SUITE 200 MINNEAPOLIS. MN 55427FAX (763) 544-0531 PH (763) 544-7129DateRegistration NumberCheckDrawnDate:CommI hereby certify that this plan, specification or report was prepared byme or under my direct supervision and that I am a duly Licensedunder the laws of the State ofRevisionsDescriptionDateNumScale:NorthGRADING PLANDAVID A. REY11/08/194018017226711/08/19CWFDAR1" = 30'C1.31CITY RESUBMITTAL 10/8/19MINNESOTAPROFESSIONAL ENGINEERISD #621: MOUNDS VIEWPUBLIC SCHOOLS4570 VICTORIA STREET NSHOREVIEW, MN 551261770 County Road E2 WArden Hills, Minnesota 55112VALENTINE HILLSELEMENTARYSCHOOL BUILDINGADDITIONS1.) Scribed "X" on south side of concrete light pole base 20 feet +/- south of most southerly building corner of school. Elevation = 906.60 feet2.) Top of nut of fire hydrant on west side of Chatham Avenue near southwest corner of school. Elevation = 911.083.) Top of nut of fire hydrant on south side of Count Road E2, east of west drive entrance to school.Elevation = 888.384.) Top of top nut of fire hydrant on south side of County Road E2, east of east drive entrance to school. Elevation = 881.99BENCHMARKS (FIELD VERIFY BEFORE USING)1.ALL CONSTRUCTION MUST COMPLY WITH APPLICABLE STATE AND LOCAL ORDINANCES.2.THE CONTRACTOR WILL BE RESPONSIBLE FOR AND SHALL PAY FOR ALL CONSTRUCTION STAKING /LAYOUT.3.THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL RELATED CONSTRUCTION PERMITS, INCLUDING THENPDES PERMIT FROM THE MPCA. SUBMIT A COPY OF ALL PERMITS TO THE CITY.4.CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TRAFFIC CONTROL SIGNAGE (CONSTRUCTION ZONES)NECESSARY TO CONSTRUCT PROPOSED IMPROVEMENTS. ALL SIGNAGE LAYOUTS MUST BE DESIGNED BYTHE CONTRACTOR AND APPROVED BY LOCAL AUTHORITIES.5.INSTALL CONTROL FENCING AND BARRICADING AS NECESSARY TO PROTECT THE PUBLIC.6.INSPECT SITE AND REVIEW SOIL BORINGS TO DETERMINE EXTENT OF WORK AND NATURE OF MATERIALSTO BE HANDLED.7.REFER TO SPECIFICATIONS FOR DEWATERING REQUIREMENTS.8.CHECK ALL PLAN AND DETAIL DIMENSIONS AND VERIFY SAME BEFORE FIELD LAYOUT.9.REFER TO ARCHITECTURAL PLANS FOR BUILDING AND STOOP DIMENSIONS AND LAYOUT.10.MAINTAIN DUST CONTROL DURING GRADING OPERATIONS.11.ALL EROSION CONTROL METHODS SHALL COMPLY WITH MPCA AND LOCAL REGULATIONS.12.CONTRACTOR SHALL MINIMIZE DISTURBANCE TO SITE AND PROTECT EXISTING SITE FEATURES (INCLUDINGTURF AND VEGETATION) WHICH ARE TO REMAIN.13.PROPOSED CONTOURS AND SPOT ELEVATIONS ARE SHOWN TO FINISH GRADE UNLESS OTHERWISE NOTED.14.SPOT ELEVATIONS SHOWN IN PARKING LOTS, DRIVES AND ROADS INDICATE GUTTER GRADES, UNLESSNOTED OTHERWISE. SPOT ELEVATIONS WITH LABELS OUTSIDE THE BUILDING PERIMETER INDICATEPROPOSED GRADES OUTSIDE THE BUILDING. SPOT ELEVATIONS WITH LABELS INSIDE THE BUILDINGPERIMETER INDICATE PROPOSED FINISH FLOOR ELEVATIONS.15.THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR DETERMINING QUANTITIES OF CUT, FILL ANDWASTE MATERIALS TO BE HANDLED, AND FOR AMOUNT OF GRADING TO BE DONE IN ORDER TOCOMPLETELY PERFORM ALL WORK INDICATED ON THE DRAWINGS. IMPORT SUITABLE MATERIAL ANDEXPORT UNSUITABLE / EXCESS / WASTE MATERIAL AS REQUIRED. ALL COSTS ASSOCIATED WITHIMPORTING AND EXPORTING MATERIALS SHALL BE INCIDENTAL TO THE CONTRACT.16.IT IS INTENDED THAT EARTHWORK (CUT VS. FILL) BALANCE ON SITE. FOR GENERAL GRADES ADJUSTMENTAREA REFER TO SECTION 31 00 00. THE CONTRACTOR SHALL SUBMIT THE QUANTITY OF MATERIAL ANDAMOUNT OF ANTICIPATED GRADE ADJUSTMENT FOR REVIEW BY THE ENGINEER A MINIMUM OF FOURWEEKDAYS PRIOR TO MAKING ADJUSTMENTS. ALL GRADE ADJUSTMENTS MUST BE APPROVED BY THEENGINEER. NO ADDITIONAL COMPENSATION WILL BE ALLOWED FOR WORK ASSOCIATED WITH GRADINGADJUSTMENTS, INCLUDING, BUT NOT LIMITED TO, EARTHWORK OPERATIONS, STORM SEWER PIPING ANDSTRUCTURE ADJUSTMENTS, CONSTRUCTION SURVEYING FOR ADJUSTING FEATURE LOCATIONSACCORDINGLY, SILT FENCE, ETC.17.NO FINISHED SLOPES SHALL EXCEED 4' HORIZONTAL TO 1' VERTICAL (4:1), UNLESS OTHERWISE NOTED.18.ALL DISTURBED AREAS OUTSIDE THE BUILDING PAD WHICH ARE NOT DESIGNATED TO BE PAVED ORRECEIVE AGLIME, SHALL RECEIVE AT LEAST 6" OF TOPSOIL AND SHALL BE SEEDED OR SODDED. REFER TOLANDSCAPING PLANS, FOR SOD AND SEED LOCATIONS. ALL OTHER AREAS DISTURBED BY CONSTRUCTIONNOT SPECIFICALLY IDENTIFIED TO RECEIVE A CERTAIN SEED MIX SHALL BE SEEDED WITH SEED MIX #2.19.WHERE NEW SOD MEETS EXISTING SOD, EXISTING SOD EDGE SHALL BE CUT TO ALLOW FOR A CONSISTENT,UNIFORM STRAIGHT EDGE. JAGGED OR UNEVEN EDGES WILL NOT BE ACCEPTABLE. REMOVE TOPSOIL ATJOINT BETWEEN EXISTING AND NEW AS REQUIRED TO ALLOW NEW SOD SURFACE TO BE FLUSH WITHEXISTING.20.FAILURE OF TURF DEVELOPMENT: IN THE EVENT THE CONTRACTOR FAILS TO PROVIDE AN ACCEPTABLETURF, THE CONTRACTOR SHALL RE-SEED OR RE-SOD ALL APPLICABLE AREAS, AT NO ADDITIONAL COST TOTHE OWNER, TO THE SATISFACTION OF THE ENGINEER.21.LOCATE ALL EXISTING UTILITIES, VERIFY LOCATION, SIZE AND INVERT ELEVATION OF ALL EXISTINGUTILITIES. VERIFY LOCATIONS, SIZES AND ELEVATIONS OF SAME BEFORE BEGINNING CONSTRUCTION.22.CONTRACTOR SHALL MAINTAIN DRAINAGE FROM EXISTING BUILDING AT ALL TIMES.GENERAL NOTESLEGENDREFERENCE KEY TO SITE DETAILS DETAIL I.D NUMBER (TOP) DETAIL SHEET NUMBER (BOTTOM)EXISTING CONTOUREXISTING SPOT ELEVATIONPROPOSED CONTOURPROPOSED SPOT ELEVATIONME = MATCH EXISTINGEOF = EMERGENCY OVERFLOWPROPOSED GRADING LIMITSPROPOSED SAND SUBBASE AT FROST FOOTED STOOPSAPPROXIMATE SOIL BORING / TEST PIT LOCATIONPROPOSED BUILDING STOOP - REFER TO ARCHITECTURAL PLANSPROPERTY LINE905905.6XX BUILDING ADDITION #2FFE = 903.90 = ARCH 100'-0"BUILDING ADDITION #1FFE = 907.90 = ARCH 104'-0"907.9907.8907.8908.0907.9ME907.4907.4907.7907.1907.4907.4907.4907.4905.0904.3904.3905.0906.0907.0897.3ME900.2ME896.4ME908.3908.4ME908.3ME907.9MEEOF 885.8886.2886.2BD 2INV. = 897.90 = MECH. 94'-0"7,060 SFBD 1INV. = 899.32 = MECH. 95'-5"37,825 SFCB 1 (EXISTING)RIM = 905.0INV. = 898.60 S (EXISING - FIELD VERIFY)INV. = 898.90 NE (EXISTING - FIELD VERIFY)INV. = 898.90 NINV. = 899.10 W (EXISTING - FIELD VERIFY)72" IDR-3067-VCONSTRUCT STRUCTURE OVER EXISTINGPIPES.29' - 15" SCH 40 PVC @ 1.38%CB 2RIM = 904.5INV. = 899.6848" IDR- 2501C42' - 12" PVC SDR 35 @ 0.44%MH 101 (EXISTING)RIM = 908.6INV. = 899.20 E/W (EXISTING - FIELD VERIFY)INV. = 899.5 NWCONNECT TO EXISTING STRUCTURE ANDPROVIDE FLEXIBLE JOINT AT PIPECONNECTIONCB 3 (EXISTING)RIM = 905.4 (EXISTING - FIELD VERIFY)INV. = 899.5 NW (EXISTING - FIELD VERIFY)INV. = 899.4 SECONNECT TO EXISTING STRUCTURE ANDPROVIDE FLEXIBLE JOINT AT PIPECONNECTION37' - 12" RCP @ 1.08%FES 1INV. = 896.00PROVIDE RIP RAP WITH GEOTEXTILE FABRIC12 ' - 12" PVC @ 1.04%MH 104RIM = 900.2INV. = 897.6248" IDR-1642MH 103RIM = 899.0INV. = 889.95 NW (EXISTING - FIELD VERIFY)INV. = 896.24 S48" IDR-1642CONSTRUCT STRUCTURE OVER EXISTINGPIPE AND PROVIDE FLEXIBLE JOINT ATPIPE CONNECTIONS46' - 12" PVC @ 3.00%267' - 15" PVCSDR 35 @ 0.34%RAIN GAURDIAN CURB INLETREPLACE CASTING WITH R-1642UGS 1SAND INV. = 897.00STONE INV. = 898.50TANK INV. = 899.00HWL = 901.10TOTAL STORAGE = 2,758 CFINFILTRATION VOLUME = 1,663 CF15 - 30" PERFORATED CMP UNITSMH 106RIM = 909.1INV. = 896.90 SINV. = 900.00 NWINV. = 897.00 DT48" IDR-1642886.8PROPOSED FILTRATION AREABOTTOM AREA = 497 SFBOTTOM ELEVATION = 885.00HWL ELEVATION = 886.03EOF ELEVATION = 885.80CB 4 (EXISTING)RIM = 884.4 (EXISTING - FIELD VERIFY)INV. = 880.9 (EXISTING - FIELD VERIFY)INV. = 882.00 DTCONNECT TO EXISTING STRUCTUREAND PROVIDE FLEXIBLE JOINT AT DTCONNECTIONMH 105RIM = 907.0INV. = 895.10 (4' SUMP)INV. = 899.1048" IDR-16425' - 12" PVCSDR 35 @2.00%20' - 15" PVCSDR 35 @0.08%INV. = 900.15INV. = 899.00DT INV. = 897.00DT INV. = 882.508855.0022.5° BEND5.00'886887888889890885.1 ME885.4 ME890.5 ME887.5 MELANDSCAPE ARCHITECTURE SITE PLANNING CIVIL ENGINEERINGANDERSON - JOHNSONASSOCIATES,INC.7575 GOLDEN VALLEY ROAD SUITE 200 MINNEAPOLIS. MN 55427FAX (763) 544-0531 PH (763) 544-7129DateRegistration NumberCheckDrawnDate:CommI hereby certify that this plan, specification or report was prepared byme or under my direct supervision and that I am a duly Licensedunder the laws of the State ofRevisionsDescriptionDateNumScale:NorthUTILITY PLANDAVID A. REY11/08/194018017226711/08/19CWFDAR1" = 30'C1.41CITY RESUBMITTAL 10/8/19MINNESOTAPROFESSIONAL ENGINEERISD #621: MOUNDS VIEWPUBLIC SCHOOLS4570 VICTORIA STREET NSHOREVIEW, MN 551261770 County Road E2 WArden Hills, Minnesota 55112VALENTINE HILLSELEMENTARYSCHOOL BUILDINGADDITIONSLEGENDREFERENCE KEY TO SITE DETAILS DETAIL I.D NUMBER (TOP) DETAIL SHEET NUMBER (BOTTOM)EXISTING CONTOUREXISTING SPOT ELEVATIONPROPOSED CONTOURPROPOSED SPOT ELEVATIONME = MATCH EXISTINGEOF = EMERGENCY OVERFLOWTW = FINISH GRADE AT HIGH SIDE OF WALLBW = FINISH GRADE AT LOW SIDE OF WALLPROPOSED GRADING LIMITSPROPOSED SANITARY SEWERPROPOSED STORM SEWERPROPOSED MANHOLE (MH)PROPOSED CATCH BASIN (CB)PROPOSED FLARED END SECTION (FES)CONNECT DRAIN TILE TO CATCH BASIN AND PROVIDE BACKWATER VALVEPROPOSED BUILDING STOOP - REFER TO ARCHITECTURAL PLANSPROPERTY LINE955XX54.611.REFER TO SHEET CXXX, XXXXXXX, FOR GENERAL NOTES.2.ALL WATERMAIN PIPE SHALL BE DIP, CLASS 52. ALL WATERMAIN SHALL HAVE MINIMUM 8'-0"BURY (TOP OF PIPE TO FINISH GRADE). DIP SHALL BE ENCASED WITH POLYETHYLENE FILMCONFORMING TO ASTM D 1248-889.3.ALL WATERMAIN SHALL BE AWWA C900, CAST IRON OD, DR 18, PVC PIPE INSTALLED INACCORDANCE WITH ASTM D2321. ALL WATERMAIN SHALL HAVE MINIMUM 8'-0" BURY (TOP OFPIPE TO FINISH GRADE).4.ALL SANITARY SEWER PIPE SHALL BE PVC PIPE (ASTM D 3034, SDR 26), UNLESS OTHERWISENOTED. SANITARY SEWER INSTALLATION SHALL BE IN ACCORDANCE WITH ASTM D2321.5.ALL STORM SEWER PIPE SHALL BE RCP, CLASS III (MIN.), WITH FLEXIBLE WATERTIGHT JOINTSIN ACCORDANCE WITH ASTM C-361 OR PVC PIPE (ASTM D3034, SDR 35) INSTALLED INACCORDANCE WITH ASTM D2321, UNLESS OTHERWISE NOTED.6.FLEXIBLE JOINTS AT STORM SEWER PIPE CONNECTIONS TO STRUCTURES:6.1.IN ACCORDANCE WITH MINNESOTA PLUMBING CODE, PROVIDE FLEXIBLE JOINTS AT ALLPIPE CONNECTIONS TO ALL STORM SEWER STRUCTURES.6.2.ACCEPTABLE MANUFACTURERS / PRODUCTS:6.3.FERNCO, “CONCRETE MANHOLE ADAPTORS” OR “LARGE-DIAMETER WATERSTOPS”6.4.PRESS-SEAL, WATERSTOP GROUTING RINGS”6.5.OR APPROVED EQUAL.7.WATERMAIN SHALL BE INSTALLED AT LEAST 10 FEET HORIZONTALLY FROM ANY MANHOLE,CATCH BASIN, STORM SEWER, SANITARY SEWER, DRAINTILE OR OTHER POTENTIAL SOURCEFOR CONTAMINATION PER MINNESOTA PLUMBING CODE. THIS ISOLATION DISTANCE SHALL BEMEASURED FROM THE OUTER EDGE OF THE PIPE TO THE OUTER EDGE OF THECONTAMINATION SOURCE (OUTER EDGE OF STRUCTURES OR PIPING OR SIMILAR).8.ANY MANHOLE, CATCH BASIN, STORM SEWER, SANITARY SEWER, DRAINTILE OR OTHERPOTENTIAL SOURCE FOR CONTAMINATION SHALL BE INSTALLED AT LEAST 10 FEETHORIZONTALLY FROM ANY WATERMAIN PER MINNESOTA PLUMBING CODE. THIS ISOLATIONDISTANCE SHALL BE MEASURED FROM THE OUTER EDGE OF THE PIPE TO THE OUTER EDGE OFTHE CONTAMINATION SOURCE (OUTER EDGE OF STRUCTURES OR PIPING OR SIMILAR).9.LOCATE ALL EXISTING UTILITIES, VERIFY LOCATION, SIZE AND INVERT ELEVATION OF ALLEXISTING UTILITIES. VERIFY LOCATIONS, SIZES AND ELEVATIONS OF SAME BEFORE BEGINNINGCONSTRUCTION.10.PRIOR TO CONSTRUCTION OF PROPOSED BUILDING UTILITY SERVICES (STORM, SANITARYSEWER, WATERMAIN), VERIFY ALL PROPOSED BUILDING UTILITY SERVICE PIPE SIZES,LOCATIONS AND ELEVATIONS WITH MECHANICAL PLANS. COORDINATE CONSTRUCTION ANDCONNECTIONS WITH MECHANICAL CONTRACTOR.11.CONTRACTOR SHALL STAKE LIMITS OF WALKS AND CURBING PRIOR TO INSTALLATION OFGATE VALVES, CATCH BASINS AND MANHOLES. GATE VALVE AND MANHOLE LOCATIONSSHALL BE ADJUSTED TO AVOID PLACEMENT OF THESE STRUCTURES IN WALKS AND CURBAND GUTTER. CURB AND GUTTER SHALL BE STAKED TO ALLOW CURB INLET TYPE CATCHBASINS TO BE PROPERLY LOCATED IN LINE WITH CURBING.NOTES BUILDING ADDITION #2FFE = 903.90 = ARCH 100'-0"BUILDING ADDITION #1FFE = 907.90 = ARCH 104'-0"907.9907.8907.8908.0907.9ME907.4907.4907.7907.1907.4907.4907.4907.4905.0904.3904.3905.0906.0907.0897.3ME900.2ME896.4ME908.3908.4ME908.3ME907.9MEEOF 885.8886.2886.2AAAAAAAAACONCRETE WASHOUT LOCATION.MARK WITH SIGN.PROVIDE DAILY SWEEPINGOF PAVED AREASPROVIDE DAILY SWEEPINGOF PAVED AREASPROVIDE DAILY SWEEPINGOF PAVED AREASPROVIDE DAILY SWEEPINGOF PAVED AREASPROVIDE DAILY SWEEPINGOF PAVED AREAS886.8PROPOSED FILTRATION AREABOTTOM AREA = 497 SFBOTTOM ELEVATION = 885.00HWL ELEVATION = 886.03EOF ELEVATION = 885.80A885886887888889890885.1 ME885.4 ME890.5 ME887.5 MELANDSCAPE ARCHITECTURE SITE PLANNING CIVIL ENGINEERINGANDERSON - JOHNSONASSOCIATES,INC.7575 GOLDEN VALLEY ROAD SUITE 200 MINNEAPOLIS. MN 55427FAX (763) 544-0531 PH (763) 544-7129DateRegistration NumberCheckDrawnDate:CommI hereby certify that this plan, specification or report was prepared byme or under my direct supervision and that I am a duly Licensedunder the laws of the State ofRevisionsDescriptionDateNumScale:NorthEROSION PLANDAVID A. REY11/08/194018017226711/08/19CWFDAR1" = 30'C1.51CITY RESUBMITTAL 10/8/19MINNESOTAPROFESSIONAL ENGINEERISD #621: MOUNDS VIEWPUBLIC SCHOOLS4570 VICTORIA STREET NSHOREVIEW, MN 551261770 County Road E2 WArden Hills, Minnesota 55112VALENTINE HILLSELEMENTARYSCHOOL BUILDINGADDITIONS1.REFER TO SHEET CXXX, XXXXXXX, FOR GENERAL NOTES.2.REFER TO SWPPP NARRATIVE (SECTION 01 89 13) FOR CONSTRUCTION SEQUENCING ANDEROSION CONTROL REQUIREMENTS.3.MAINTAIN ADJACENT PROPERTY AND PUBLIC STREETS CLEAN FROM CONSTRUCTION CAUSEDDIRT AND DEBRIS ON A DAILY BASIS. PROTECT DRAINAGE SYSTEMS FROM SEDIMENTATION ASA RESULT OF CONSTRUCTION RELATED DIRT AND DEBRIS.4.MAINTAIN DUST CONTROL DURING GRADING OPERATIONS.5.ALL EROSION CONTROL METHODS SHALL COMPLY WITH MPCA AND OTHER LOCALREGULATIONS.6.IF EROSION AND SEDIMENT CONTROL MEASURES TAKEN ARE NOT ADEQUATE AND RESULT INDOWNSTREAM SEDIMENT, THE CONTRACTOR SHALL BE RESPONSIBLE FOR CLEANING OUTDOWNSTREAM STORM SEWERS AS NECESSARY, INCLUDING ASSOCIATED RESTORATION.7.INLET PROTECTION DEVICE AT STORM SEWER INLETS. AT THE INLETS TO ALL STORM SEWERSTRUCTURES, PROVIDE A PRODUCT FROM THE FOLLOWING LIST. APPROVED PRODUCTS:a.ROAD DRAIN "TOP SLAB", MANUFACTURED BY WIMCOb.ROAD DRAIN "CURB & GUTTER", MANUFACTURED BY WIMCOc.INFRASAFE "SEDIMENT CONTROL BARRIER", MANUFACTURED BY ROYALENVIRONMENTAL SYSTEMS, INC.d.INFRASAFE "DEBRIS COLLECTION DEVICE", MANUFACTURED BY ROYALENVIRONMENTAL SYSTEMS, INC.e.INFRASAFE "CULVERT INLET PROTECTOR", MANUFACTURED BY ROYAL ENVIRONMENTALSYSTEMS, INC.f.DANDY SACK, MANUFACTURED BY DANDY PRODUCTS, INC.g.DANDY CURB SACK, MANUFACTURED BY DANDY PRODUCTS, INC.h.OR APPROVED EQUAL.8.PRIOR TO CONSTRUCTION, DELINEATE TURF AND VEGETATED AREAS NOT TO BE DISTURBEDWITH ORANGE SNOW FENCE. NO CONSTRUCTION TRAFFIC, EQUIPMENT OR MATERIALS SHALLBE PERMITTED TO UTILIZE, ACCESS, OR OTHERWISE ENTER THE AREAS DESIGNATED NOT TOBE DISTURBED. MINIMIZE SOIL COMPACTION AND DISRUPTION OF TOPSOIL IN AREAS OUTSIDETHE CONSTRUCTION LIMITS TO COMPLY WITH MN CONSTRUCTION STORMWATER GENERALPERMIT.NOTESLEGENDREFERENCE KEY TO SITE DETAILS DETAIL I.D NUMBER (TOP) DETAIL SHEET NUMBER (BOTTOM)EXISTING CONTOUREXISTING SPOT ELEVATIONPROPOSED CONTOURPROPOSED SPOT ELEVATIONME = MATCH EXISTINGEOF = EMERGENCY OVERFLOWTW = FINISH GRADE AT HIGH SIDE OF WALLBW = FINISH GRADE AT LOW SIDE OF WALLPROPOSED GRADING LIMITSPROPOSED STORM SEWERPROPOSED MANHOLE (MH)PROPOSED CATCH BASIN (CB)PROPOSED FLARED END SECTION (FES)PROPOSED UNDERGROUND STORAGE UNITSPROPOSED SILT FENCEPROPOSED SEDIMENT CONTROL LOGPROPOSED EROSION CONTROL BLANKETPROPOSED TEMPORARY DIVERSION BERMINLET PROTECTION DEVICE AT STORM SEWER INLETPROPOSED BUILDING STOOP - REFER TO ARCHITECTURAL PLANSPROPERTY LINEXX95554.6A LANDSCAPE ARCHITECTURE SITE PLANNING CIVIL ENGINEERINGANDERSON - JOHNSONASSOCIATES,INC.7575 GOLDEN VALLEY ROAD SUITE 200 MINNEAPOLIS. MN 55427FAX (763) 544-0531 PH (763) 544-7129DateRegistration NumberCheckDrawnDate:CommI hereby certify that this plan, specification or report was prepared byme or under my direct supervision and that I am a duly Licensedunder the laws of the State ofRevisionsDescriptionDateNumScale:NorthSITE DETAILSDAVID A. REY11/08/194018017226711/08/19CWFDAR1" = 30'C2.11CITY RESUBMITTAL 10/8/19MINNESOTAPROFESSIONAL ENGINEERISD #621: MOUNDS VIEWPUBLIC SCHOOLS4570 VICTORIA STREET NSHOREVIEW, MN 551261770 County Road E2 WArden Hills, Minnesota 55112VALENTINE HILLSELEMENTARYSCHOOL BUILDINGADDITIONSPIPE BEDDING - PVCNOTES:TRENCH SIDEWALLS TO MEET O.S.H.A REQUIREMENTS.UPPER 3 FT. OF BACKFILL SHALL BE COMPACTED TO AT LEAST 100%STANDARD PROCTOR DRY DENSITY. BELOW THIS ELEVATION, BACKFILLSHALL BE COMPACTED TO AT LEAST 95% STANDARD PROCTOR DRY DENSITY.SEWER INSTALLATION SHALL BE IN ACCORDANCE WITH ASTM D2321.DEPTH (VARIES)6" MIN.1/8 O.D.(6" MIN.)O.D. + 2' (MAX)PIPE DIA.FINAL SUBGRADEHAND TAMPEDSANDC2.1111SILT FENCENORMAL USEPOSTS:(IF USED WITHOUTSUPPORT FENCE) WOOD2" SQ. (MIN)@ 4' (MAX)SPACING METAL0.95 lbs/lf (MIN.) @ 6'(MAX) SPACINGDIRECTION OFRUNOFF FLOWNOTE: DEPENDING UPON CONFIGURATION, ATTACH TO WIRE MESH WITHHOG RINGS, STEEL POSTS WITH TIE WIRES, OR WOOD POSTS WITH STAPLES5' MIN. LENGTH POST (METAL)4' MIN. LENGTH POST (WOOD)SILT FENCE FABRICOVERLAP FABRIC 6" ANDFASTEN @ 2' INTERVALSEXTEND WIRE MESH INTO TRENCHFABRIC ANCHORAGETRENCH BACKFILL WITHTAMPED NATURAL SOIL6" MIN.6" MIN.NATURAL SOIL24" MIN. BURY DEPTH (METAL)18" MIN BURY DEPTH (WOOD)30" MIN.METAL STAKE ORWOOD POSTOPTIONAL SUPPORTFENCE (WIRE MESH)6"6"12"6"2.4.5.3B.1.3A.EROSION CONTROL BLANKET1. PREPARE SOIL BEFORE INSTALLING BLANKETS, INCLUDING ANY NECESSARYAPPLICATION OF LIME, FERTILIZER, AND SEED.2. BEGIN AT THE TOP OF THE SLOPE BY ANCHORING THE BLANKET IN A 6" DEEP X 6" WIDETRENCH WITH APPROXIMATELY 12" OF BLANKET EXTENDED BEYOND THE UP-SLOPEPORTION OF THE TRENCH. ANCHOR THE BLANKET WITH A ROW OF STAPLES/STAKESAPPROXIMATELY 12" APART IN THE BOTTOM OF THE TRENCH. BACKFILL AND COMPACTTHE TRENCH AFTER STAPLING. APPLY SEED TO COMPACTED SOIL AND FOLD REMAINING12" PORTION OF BLANKET BACK OVER SEED AND COMPACTED SOIL. SECURE BLANKETOVER COMPACTED SOIL WITH A ROW OF STAPLES/STAKES SPACED APPROXIMATELY 12"APART ACROSS THE WIDTH OF THE BLANKET.3. ROLL THE BLANKETS (A.) DOWN OR (B.) HORIZONTALLY ACROSS THE SLOPE. BLANKETSSHALL UNROLL WITH APPROPRIATE SIDE AGAINST THE SOIL SURFACE. ALL BLANKETSMUST BE SECURELY FASTENED TO SOIL SURFACE BY PLACING STAPLES/STAKES INAPPROPRIATE LOCATIONS AS SHOWN IN THE STAPLE PATTERN GUIDE. WHEN USINGOPTIONAL DOT SYSTEM , STAPLES/STAKES SHOULD BE PLACED THROUGH EACH OF THECOLORED DOTS CORRESPONDING TO THE APPROPRIATE STAPLE PATTERN.4. THE EDGES OF PARALLEL BLANKETS MUST BE STAPLED WITH APPROXIMATELY 6"OVERLAP DEPENDING ON BLANKET TYPE. TO ENSURE PROPER SEAM ALIGNMENT, PLACETHE EDGE OF THE OVERLAPPING BLANKET (BLANKET BEING INSTALLED ON TOP) EVENWITH THE COLORED SEAM STITCH ON THE PREVIOUSLY INSTALLED BLANKET.5. CONSECUTIVE BLANKETS SPLICED DOWN THE SLOPE MUST BE PLACED END OVER END(SHINGLE STYLE) WITH AN APPROXIMATE 6" OVERLAP. STAPLE THROUGH OVERLAPPEDAREA, APPROXIMATELY 12" APART ACROSS ENTIRE BLANKET WIDTH.6. BLANKET SHALL BE STAPLED AS PER MANUFACTURER'S RECOMMENDATION.NOTE: *IN LOOSE SOIL CONDITIONS, THE USE OF STAPLE ORSTAKE LENGTHS GREATER THAN 6" (15cm) MAY BE NECESSARYTO PROPERLY SECURE THE BLANKETS.6"SEDIMENT CONTROL LOGFLOW24" MIN. 2' O . C . M A X .FLOWFLOWSTAKE DETAILINSTALLATION DETAILSEDIMENT CONTROL LOGSTAKE TO BE PLACED AT TOEOF SLOPE, BOTH SIDESWOOD STAKEBOTTOM OF SWALEWOOD STAKE TOPENETRATE NETTINGMATERIAL ONLYSEDIMENT CONTROL LOGCATCH BASINVARIESFLOWFLOW61"RIM ELEVATION"PRECAST COVER -8" THICKSTEPS - INSTALL ONDOWNSTREAM SIDE@ 16" O.C.RUBBER GASKET -TYP AT ALL JOINTSPRECAST CONCRETESECTIONGROUT SHELF ANDCHANNELSBASES SHALL BE 8"STANDARD PRECASTWITH 2" LEAN GROUT,OR POURED 8" SLABREINFORCED WITH6" x 6" 10/10 MESHPROVIDE FLEXIBLE JOINTAT CONNECTION -REFER TO SPECSSTORM SEWER PIPE- REFER TOPLAN FOR LOCATION, INVERT,AND SIZESMIN. 2 AND MAX. 5 ADJUSTINGRINGS. GROUT BETWEENRINGS, CASTING, AND ALONGOUTSIDE.METAL SEWER CASTING - REFERTO PLAN FOR TYPESTORM SEWER MANHOLE48"FLOWFLOW61BASES SHALL BE 8" STANDARD PRECAST WITH 2" LEAN GROUT,OR POURED 8" SLAB REINFORCED WITH 6" x 6" 10/10 MESHCOVER SHALL BESTAMPED"STORM SEWER""RIM ELEVATION"PRECAST COVER -8" THICKSTEPS - INSTALL ONDOWNSTREAM SIDE@ 16" O.C.RUBBER GASKET -TYP AT ALL JOINTSPRECAST CONCRETESECTIONPROVIDE FLEXIBLEJOINT - REFER TOSPECSGROUT SHELF ANDCHANNELSPROVIDE FLEXIBLE JOINT -REFER TO SPECSSTORM SEWER PIPE - SEEPLAN FOR LOCATION,INVERT, AND SIZESMIN. 2 AND MAX. 5 ADJUSTINGRINGS. GROUT BETWEENRINGS, CASTING, AND ALONGOUTSIDE.METAL SEWER CASTING - REFERTO PLAN FOR TYPERCP FLARED END SECTION(FES)PIPE SIZE21" & LESS24" TO 36"42" TO 54"60" & GREATER"U" BOLT DIA.1/2"5/8"3/4"1"WIDTH24"24"24"24""U" BOLT REQUIREMENTSNOTES:2 - "U" BOLT FASTENERS TO BE INSTALLED ACROSS EACHJOINT, ONE EACH SIDE OF PIPE AT 60° FROM THE TOP OFTHE PIPE. FASTEN FIRST THREE JOINTS AS SHOWN.CONCRETE PIPE TIES ("U" BOLTS)TRASH GUARD WITH 5/8" DIA.RODS AT 6" ON CENTER.FASTEN TO FES WITH 3HOT DIPPED GALV. CLIPSRIPRAP - REFERTO DETAILTYPICAL SECTION THRUFILTRATION AREAFILTRATION AREALIMITS AS SHOWN ON PLANSEE NOTE 7 OF 11 / C7.1 FOR ENGINEERED SOIL MIXTUREPLACE SEDIMENT LOG AT EDGE OF FILTRATION AREA - FULLPERIMETER , AND REMOVE ONCE ALL UPSLOPE AREAS AREFULLY STABILIZED (PERMANENT STABILIZATION)FLAT BOTTOM11EXCAVATE TO SUBGRADEELEVATION WITH A TOOTHEDBUCKET BACKHOE. RIP SOILS 6"TO 9" TO REMOVE COMPACTIONUTILITY TRACERWIRE (TYPICAL)6" DRAIN TILE WITH 3" MIN. PEA ROCKSURROUNDING, WRAPPED IN GEOTEXTILE FABRIC- REFER TO PLAN FOR LOCATION AND INVERT6" MIN.GRASSFILTRATION SYSTEM SOILMIXTURE - SEE BELOW6" DEPTHTOPSOILMINERAL SOD30" MIN.IMPERMEABLELINERPIPE BEDDING - RCP & DIPNOTES:TRENCH SIDEWALLS TO MEET O.S.H.A REQUIREMENTS.UPPER 3 FT. OF BACKFILL SHALL BE COMPACTED TO AT LEAST 100%STANDARD PROCTOR DRY DENSITY. BELOW THIS ELEVATION, BACKFILLSHALL BE COMPACTED TO AT LEAST 95% STANDARD PROCTOR DRY DENSITY.DEPTH (VARIES) 1/8 DEPTH (12" MIN.)1/6 O.D. 1/8 O.D. (4" MIN.)O.D. + 2' (MAX)FINAL SUBGRADELIGHTLYCOMPACTEDFILLCOMPACTED CRUSHED ROCKOR PEA GRAVEL - 100% PASSINGTHE 34" SIEVE AND A MAXIMUMOF 5% PASSING THE #10 SIEVE.BACKWATER VALVEFLOWBACKWATER VALVESOLVENT WELD BACKWATERVALVE TO DRAINTILEPROVIDE FLEXIBLE JOINT -REFER TO SPECS6" DRAINTILECONNECT DRAINTILE TOSTRUCTURE AT ELEVATIONSHOWN ON THE DRAWING.GROUT SECURE TO STRUCTUREWALLMINIMIZE STUB THROUGH WALL.STUB ONLY AS REQUIREDTO ALLOW BACKWATER VALVETO BE CONNECTED TO DRAINTILEPROVIDE FLEXIBLEJOINT ATCONNECTION -REFER TO SPECSREFER TO PLAN FORSTRUCTURE TYPE14C2.11ENGINEERED FILL10" 6"UNSUITABLE SOILTOPSOIL1'-0" (TYP)3'-0"11VARIESNOTE:BOTTOM OF EXCAVATION MUST BE APPROVED BY THE SOILSENGINEER PRIOR TO PLACEMENT OF ANY FILL.4" SLAB AND 6" SAND SUBBASE - VERIFYWITH ARCHITECTURAL PLANSFINISH FLOORFINISH SUBGRADEFINISH GRADE (TURF)MINIMUM EXCAVATIONLIMITSFOOTINGSUITABLE SOILENGINEERED FILL9C2.11SAND SUBBASE/ DRAIN TILE ATDOORS & FROST FOOTED STOOPS5'-0"20'-0"5'-0" 6'-0" 4"NOTE: REFER TO GRADING AND DRAINAGEPLAN FOR LIMITS OF SAND SUB-BASEFINISH GRADEAT EDGE OF STOOPFINISH GRADEOF PAVEMENT ADJACENTTO FOOTED STOOPSTOOP FOOTINGREFER TO STRUCTURALDRAWINGS6" DRAIN TILE (WHERE INDICATEDON DRAWINGS) - EXTEND TOSTORM SEWER STRUCTUREWHERE INDICATED ONDRAWINGSSUBGRADE SOILSSAND SUBBASEC2.138C2.1110FILTRATION AREACONSTRUCTION NOTESFILTRATION AREA CONSTRUCTION SHALL COMPLY WITH THE FOLLOWING:1.FILTRATION AREA LIMITS SHALL BE SURVEYED AND A VISUAL BARRIER, SUCH AS ORANGE SNOW FENCE, SHALL BEPLACED AROUND THE FULL PERIMETER TO KEEP ALL CONSTRUCTION TRAFFIC, EQUIPMENT AND MATERIAL STOCKPILESOUT OF THE PROPOSED FILTRATION AREA. THE VISUAL BARRIER MUST BE INSTALLED BEFORE NEW CONSTRUCTIONBEGINS AND SHALL BE MAINTAINED THROUGH THE DURATION OF THE PROJECT.2.DELIVER SAMPLE MATERIALS ONSITE FOR PRIOR APPROVAL. PRIOR TO BEGINNING THE INSTALLATION, SUFFICIENTMATERIAL QUANTITIES SHALL BE ONSITE TO COMPLETE THE INSTALLATION AND STABILIZE EXPOSED SOIL AREASWITHOUT DELAY.3.CARE MUST BE TAKEN TO AVOID CONTAMINATION OF ENGINEERED SOILS WITH SEDIMENT, IN-SITU OR TOPSOIL DURINGAND AFTER INSTALLATION. MATERIALS MUST BE SEGREGATED.4.INSTALLATION WITH DRY SOIL CONDITIONS IS CRITICAL TO PREVENT SMEARING AND COMPACTION. SCHEDULE WORKFOR PERIODS OF DRY WEATHER. DO NOT WORK IF SOIL CONDITIONS ARE WET. EXCAVATION, SOIL PLACEMENT ANDRAPID STABILIZATION OF PERIMETER SLOPES WITH TURF SOD MUST COMPLETED BEFORE THE NEXT PRECIPITATIONEVENT. TURF SOD PLACED IN FLOW PATHS SHALL BE SECURED WITH AT LEAST 6 STAKES PER SQUARE YARD. PLACESTAKES ALONG UPHILL SEAM EDGES TO PREVENT UNDERMINING FLOWS UNTIL SOD ROOTS ESTABLISH.5.DO NOT LEAVE STORMWATER AREAS AND / OR PERIMETER SLOPES EXPOSED OVERNIGHT. SECURE THE SITE FROM RISKOF PRECIPITATION DAMAGES AT THE END OF EVERY WORK DAY. IN THE EVENT OF RAIN, TAKE ACTION TO DIVERTSTORMWATER AWAY FROM THE WORK AREA AND TEMPORARILY COVER OF ALL EXPOSED SOILS WITH FILTER FABRICOR IMPERMEABLE SHEETING.6.FIELD OBSERVATION OF EXCAVATION AND SOIL PLACEMENT IS REQUIRED. NOTIFY GEOTECHNICAL ENGINEER PRIOR TODIGGING. USE BACKHOE WITH TOOTH BUCKET FOR CELL EXCAVATION TO AVOID COMPACTING OR SMEARING OF SOILS.(DO NOT USE SKID STEER FOR EXCAVATION WITHIN THE CELL) USE TOOTH BUCKET TO SCARIFY (RIP) UNDERLYINGSOILS 6" TO 9" DEEP TO REMOVE COMPACTION. GENTLY MIX THE FIRST LIFT OF ENGINEERED SOILS WITH THE LOOSENEDUNDERLYING SOILS TO AVOID STRATIFICATION AND PROMOTE PERMEABILITY. USE EXCAVATOR BUCKET TO PLACEMATERIALS. CONSTRUCTION EQUIPMENT SHALL NOT BE ALLOWED INTO THE STORMWATER AREAS. LEVELING ANDFINAL GRADING WITHIN THE CELL MUST BE COMPLETED BY HAND.7.FILTRATION AREA SOIL MIX SHALL BE MINNESOTA STORMWATER MANUAL 4.1.2 MIX B: ENHANCED FILTRATION BLEND(WELL BLENDED MIXTURE OF 70% ASTM C-33 COARSE WASHED SAND (MN/DOT 3126) AND 30% MN/DOT 3890 GRADE 2LEAF LITTER COMPOST. THE MATERIAL SUPPLIER SHALL PROVIDE DOCUMENTATION THAT THE COMPOST HAS BEENSAMPLED AND TESTED AS REQUIRED BY THE SEAL OF TESTING ASSURANCE (STA) PROGRAM OF THE UNITED STATESCOMPOSTING COUNCIL (USCC) AND A GRADATION SIEVE ANALYSIS FOR THE WASHED SAND. THE ENGINEERED SOILSHALL NOT CONTAIN ANY TOPSOIL OR FILTER AGGREGATE WITH FINES.8.INSTALL PLANTINGS BY HAND.9.INSTALLED SOD AND PLANTINGS REQUIRE A TOTAL OF 1" OF WATER PER WEEK AND ACTIVE WEED MANAGEMENT UNTILWELL ESTABLISHED. WATERING COSTS ARE CONSIDERED INCIDENTAL TO SOD AND PLANTING INSTALLATION.CONSTRUCT A TEMPORARY IRRIGATION SYSTEM, CONSISTING OF ABOVE GROUND HEADS, PIPING, VALVES, ETC., FORWATERING UNTIL VEGETATION IS ESTABLISHED. DO NOT USE A WATER TRUCK AS THE FORCE OF THE WATER WILLADVERSELY AFFECT THE STORMWATER AREA SOILS.10.REMOVAL OF ACCUMULATED SEDIMENT AND DEBRIS SHALL BE DONE BY HAND OR, IF SELF-PROPELLED EQUIPMENT ISREQUIRED, FROM OUTSIDE THE PERIMETER OF THE FILTRATION AREAS.C2.1113GRADING - BELOW GRADEBUILDING WALLSBUILDING PAD(ENGINEERED FILL)11FINISH GRADE(TURF AREAS)FINISH FLOORELEVATIONBACKFILL ATBELOW GRADEWALLSFOOTING (REFER TOSTRUCTURAL PLANS)FINISH FLOOR ELEVATIONREFER TO ARCHITECTURALPLANS FOR VERIFICATION INLOWER LEVEL FINISH FLOORELEVATIONS AND LOCATIONSOF VARIATIONS2'-0"30°0'0"6"12" TOPSOIL OVER BACKFILL6" TOPSOILDetail NumberSheet NumberRIPRAP - FLARED ENDSECTIOND 515D2'-0" D 5D12"PLANSECTION A - ASECTION B - B12" 18"BBAACLASS III RIPRAPGEOTEXTILE FABRICPLAN FINISH GRADECLASS III RIPRAPGEOTEXTILE FABRICPLAN FINISH GRADEFABRIC SHALL COVER THE AREAOF THE RIPRAP AND EXTENDUNDER THE CULVERT APRON 3' LANDSCAPE ARCHITECTURE SITE PLANNING CIVIL ENGINEERINGANDERSON - JOHNSONASSOCIATES,INC.7575 GOLDEN VALLEY ROAD SUITE 200 MINNEAPOLIS. MN 55427FAX (763) 544-0531 PH (763) 544-7129DateRegistration NumberCheckDrawnDate:CommI hereby certify that this plan, specification or report was prepared byme or under my direct supervision and that I am a duly Licensedunder the laws of the State ofRevisionsDescriptionDateNumScale:NorthSITE DETAILSDAVID A. REY11/08/194018017226711/08/19CWFDAR1" = 30'C2.12CITY RESUBMITTAL 10/8/19MINNESOTAPROFESSIONAL ENGINEERISD #621: MOUNDS VIEWPUBLIC SCHOOLS4570 VICTORIA STREET NSHOREVIEW, MN 551261770 County Road E2 WArden Hills, Minnesota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Ø(INCHES)2-2/3"X1/2"(SQ. INCHES)3"X1"(SQ. INCHES)7270.978.4ULTRA-FLO(SQ. INCHES)5"x1"(SQ. INCHES)62.877.5NOTES:1. PERFORATIONS MEET AASHTO AND ASTM SPECIFICATIONS.2. PERFORATION OPEN AREA PER SQUARE FOOT OF PIPE IS BASED ON THENOMINAL DIAMETER AND LENGTH OF PIPE.3. ALL DIMENSIONS ARE SUBJECT TO MANUFACTURING TOLERANCES.4. ALL HOLES 3/8"Ø.NOTES:1.ALL HOLES ARE 3/8" DIAMETER,AND ARE NOTED AS 'CLASS 2PERFORATIONS' PER AASHTO AND ASTM.2.GAGE AND COATING LIMITATIONS APPLY. 5" X 1" IS NOT AVAILABLEIN ALUMINUM.3.ALL DIMENSIONS ARE SUBJECT TO MANUFACTURING TOLERANCES.9@2.711" = 24.399"2.711"COIL WIDTHOPEN AREA = 3.33 SQ. IN/ SQ FT.1.75" CC(TYP)18C2.11MANHOLE CAPNOTES1.DESIGN IN ACCORDANCE WITH AASHTO, 17th EDITION AND ACI 350.2.DESIGN LOAD HS25.3.EARTH COVER = 1' MAX.4.CONCRETE STRENGTH = 4,500 psi5.REINFORCING STEEL = ASTM A615, GRADE 60.6.PROVIDE ADDITIONAL REINFORCING AROUND OPENINGS EQUAL TO THE BARSINTERRUPTED, HALF EACH SIDE. ADDITIONAL BARS TO BE IN THE SAME PLANE.7.TRIM OPENING WITH DIAGONAL #4 BARS, EXTEND BARS A MINIMUM OF 12" BEYONDOPENING, BEND BARS AS REQUIRED TO MAINTAIN BAR COVER.8.PROTECTION SLAB AND ALL MATERIALS TO BE PROVIDED AND INSTALLED BYCONTRACTOR.SECTION VIEWPLAN VIEW54"Ø30" CMP RISER32"1" GAP (TYP. ALL SIDES) 2" COVER TYP. 8"12"CMP PROTECTION SLABØ36" MAX., HS-25 ACCESSCASTING TO BE PROVIDED ANDINSTALLED BY CONTRACTOR11" TYP.2" COVER (TYP.)Ø54"Ø32"2" COVER (TYP . )#4 DIAGONAL TRIMBAR (TYP. 4 PLACES),SEE NOTE 7.OPENING INPROTECTION SLABFOR CASTINGINTERRUPTED BARREPLACEMENT, SEE NOTE 6.REINFORCING -#5 @ 10" OCEW14C2.11RISER LADDERELEVATIONPLAN(4) 116" FILLET WELDS FROMEACH ANGLE CORRUGATIONCREST (2 WELDS EACH SIDE)RISER(4) ∠3x3x3/16512" LONG(2) 14" FILLET WELDS 1" LONG FROMEACH ANGLE TO LADDER RAIL16"LADDER RAILS AND RUNGSAARISER - NORMALLY223" x 12" CMP(4) 116" FILLET WELDSFROM EACH ANGLETO CORRUGATIONCREST (2 WELDSEACH SIDE)∠3x3x3/16512" LONG±3"6"LADDER RAILS AND RUNGSSECTION A-ALADDER RAILS AND RUNGSRISER NORMALLY CMP WITH223" x 12" CORRUGATIONS(4) 116" FILLET WELDS FROMEACH ANGLE TOCORRUGATION CREST (2WELDS EACH SIDE)∠3x3x3/16512" LONG(2) 14" FILLET WELDS 1" LONGATTACHMENT ANGLEMINIMUM OF 4 ANGLES PER LADDERSECTION, (2 EACH SIDE OF LADDER) 6'MAX. SPACING VERTICALLYLADDER DETAIL16"6"212"6"12" TYP. CENTER TOCENTER RUNG SPACING34" (#6) REBAR. CAN E CUTFLUSH TO OUTSIDE OFRAIL (BAR LENGTH = 1634")OR BAR CAN EXTENDBEYOND RAIL 12"±FABRICATION TOLERANCE: ±14"FLAT BAR AND REBAR: MILLTOLERANCE APPLIES78" HOLE WITH 34" REBAR RUNG,WELD REBAR TO RUNG ONOUTSIDE OF STEEL RAIL212" x 38" FLAT BAR SIDE RAILLADDERS CAN BE MADE IN 20'-0"STANDARD LENGTHS AND CUT TO FITRISER WITH LADDER AND STEPSMAINLINE CMP2 23 x 12, 5x1, 3x1, ETC.℄ PIPE 1'-6" MAX.1'-0"∠5x3x14 x 16" LONGAT 1'-0" SPACING. LONG LEG TOPROJECT OUT. WELD TOP ANDBOTTOM OF 3" LEG TO EACHCORRUGATION CREST (THESEANGLES SHOULD BE USED FORLARGER DIAMETER MAINLINESWHERE ADDITIONAL STEPS ARENEEDED)15C2.1110-C BANDNOTES1.BANDS SHALL BE NORMALLY FURNISHED AS FOLLOWS: 2-PIECE2.BAND FASTENERS SHALL BE ATTACHED WITH SPOT WELDS, RIVETS OR HAND WELDS.3.REROLLED ANNULAR END CORRUGATIONS SHALL BE 2-2/3" X 1/2". DIMENSIONS ARESUBJECT TO MANUFACTURING TOLERANCES.SECTIONCONNECTION DETAIL2512"10-C CORRUGATE BAND2-2/2"X1/2"RE-ROLLED PIPE2512"24"458"12"Ø BOLT(2) 24" TECHCO BAND ANGLESPER DRAWINGS 100841319C2.11SECTION THROUGH UNDERGROUND STORAGECORRUGATEDMETALPERFORATEDPIPE (TANK)30" (TYPICAL)GEOTEXTILE FABRIC (REFER TOSPEC SECTION 33 40 00)BURRITO WRAP (ENTIRE ASSEMBLY)MIN 24" SEAM OVERLAPPREPARED SUBGRADE21INV. = 899.00BOTTOM OFSTONE = 898.50SELECTGRANULARFILLTOP OF STONE/GEOTEXTILEFABRIC = ELEV. 902.0015"(TYPICAL)DEPTH VARIES OPEN GRADED STONE12" MIN(TYPICALFOR SIDES18C2.11BOTTOM OFSAND = 897.006" MIN6" DRAINTILEMIN. 3" PEA ROCK AROUND TILEFIRESTONE EPDM 45 MILLINER AVAILABLELOCALLY FROM BROCKWHITE" INSTALL PERMANUFACTURER'SRECOMMENDATIONSC2.1117STRUCTURE WITH HOODEDOUTLET COVERVARIESREFER TO PLANSFLOWFLOWSUMP VARIESREFER TO PLANSPROVIDE FLEXIBLE JOINT(TYP.) - REFER TO SPECSPRECAST CONCRETESECTIONSIMILAR TORUBBER GASKET - TYPAT ALL JOINTSPROVIDE ANTI-SIPHONDEVICEPRECAST COVER -8" THICK"RIM ELEVATION"METAL SEWER CASTING -REFER TO PLANS FOR TYPEMIN. 2 AND MAX. 5 ADJUSTINGRINGS. GROUT BETWEEN RINGS,CASTING, AND ALONG OUTSIDE.HOODED OUTLET COVERINLET PIPES - ADJUSTOPENING IN STRUCTUREAS REQUIRED TO ALLOWADEQUATE SPACE FORHOODED OUTLET COVER.REFER TO PLANS FOR PIPESIZES AND ALIGNMENTBASES SHALL BE 8"STANDARD PRECASTWITH 2" LEAN GROUT, ORPOURED 8" SLABREINFORCED WITH 6" x 6"10/10 MESHCONSTRUCTION LOADINGDIAGRAMCONSTRUCTION LOADSFOR TEMPORARY CONSTRUCTION VEHICLE LOADS, AN EXTRA AMOUNT OF COMPACTED COVERMAY BE REQUIRED OVER THE TOP OF THE PIPE. THE HEIGHT-OF-COVER SHALL MEET THE MINIMUMREQUIREMENTS SHOWN IN THE TABLE BELOW. THE USE OF HEAVY CONSTRUCTION EQUIPMENTNECESSITATES GREATER PROTECTION FOR THE PIPE THAN FINISHED GRADE COVER MINIMUMSFOR NORMAL HIGHWAY TRAFFIC.PIPE SPAN,INCHES18-50MINIMUM COVER (FT)AXLE LOADS (kips)50-7575-110110-15012-422.02.53.03.04.03.53.048-723.03.078-1203.54.04.04.54.54.0126-1443.5*MINIMUM COVER MAY VARY, DEPENDING ON LOCAL CONDITIONS. THE CONTRACTOR MUST PROVIDETHE ADDITIONAL COVER REQUIRED TO AVOID DAMAGE TO THE PIPE. MINIMUM COVER IS MEASUREDFROM THE TOP OF THE PIPE TO THE TOP OF THE MAINTAINED CONSTRUCTION ROADWAY SURFACE.HEIGHTOF COVERTEMPORARY COVER FORCONSTRUCTION LOADSFINISHGRADE13C2.12UGS ASSEMBLYNOTES·ALL RISER AND STUB DIMENSIONS ARE TO CENTERLINE.·ALL FITTINGS AND REINFORCEMENT COMPLY WITH ASTM A998.·ALL RISERS AND STUBS ARE 223" x 12" CORRUGATION AND 16 GAGE UNLESS OTHERWISE NOTED.·RISERS TO BE FIELD TRIMMED TO GRADE.·QUANTITY OF PIPE SHOWN DOES NOT PROVIDE EXTRA PIPE FOR CONNECTING THE SYSTEM TO EXISTING PIPE OR DRAINAGE STRUCTURES. OUR SYSTEM AS DETAILED PROVIDES NOMINAL INLET AND/OR OUTLET PIPE STUB FOR CONNECTION TO EXISTING DRAINAGE FACILITIES. IF ADDITIONAL PIPE IS NEEDED IT IS THE RESPONSIBILITY OF THE CONTRACTOR.ASSEMBLYPIPE STORAGE: 1,522 CFSTRUCTURAL BACKFILL STORAGE: 1,236 CFTOTAL STORAGE PROVIDED: 2,758 CFLOADING: H20PIPE INV. = 899.00'STUB INFORMATIONPIECESTUB INVERTSYSTEMINVERT15"Ø STUB A1900.15899.0012"Ø STUB F1899.00899.00FPGPHP30"Ø BULKHEADTYP. OF 310'-0"15'-0"30"Ø RISER8'-0"36"Ø RISERTYP. OF 2102'-6"PPPPPPPPPA1'-3"15"Ø STUB A11'-3"12" STUB F112C2.12 PT4PM1PM2CO1CO1885886887888889890LANDSCAPE ARCHITECTURE SITE PLANNING CIVIL ENGINEERINGANDERSON - JOHNSONASSOCIATES,INC.7575 GOLDEN VALLEY ROAD SUITE 200 MINNEAPOLIS. MN 55427FAX (763) 544-0531 PH (763) 544-7129DateRegistration NumberCheckDrawnDate:CommI hereby certify that this plan, specification or report was prepared byme or under my direct supervision and that I am a duly Licensedunder the laws of the State ofRevisionsDescriptionDateNumScale:NorthOVERALLLANDSCAPINGLAURA J. DETZLER11/08/195375317226711/08/19CWFDAR1" = 30'C3.12CITY RESUBMITTAL 10/8/19MINNESOTALANDSCAPE ARCHITECTISD #621: MOUNDS VIEWPUBLIC SCHOOLS4570 VICTORIA STREET NSHOREVIEW, MN 551261770 County Road E2 WArden Hills, Minnesota 55112VALENTINE HILLSELEMENTARYSCHOOL BUILDINGADDITIONS1'-0"MIN1'-0"MIN2.5 X BALL DIA. MIN.DECIDUOUS TREESET TREE WITH ROOT COLLAR ATFINISH GRADE - ADJUST TREE ASREQUIRED SO THAT ROOT COLLARSTANDS LEVEL TO OR SLIGHTLYABOVE FINISHED GRADESHREDDED HARDWOOD MULCH(4" MIN DEPTH)PLANTING SOIL (MIN. DIMENSIONSHOWN)SOIL SAUCER: USED PREPAREDSOIL (4" MIN.)ROPES AT TOP OF BALL SHALL BECUT. REMOVE TOP 1/3 OF BURLAP.NON-BIODEGRADABLE MATERIALSHALL BE TOTALLY REMOVED.PREPARED SUBSOIL TO FORMPEDESTAL TO PREVENT SETTLING.LEGENDPROPOSED DECIDUOUS TREEAPPROXIMATE SOD LIMITSPROPERTY LINE CAFETERIA LEVEL104'-0"T.O. MASONRY119'-8"MAIN LEVEL100'-0"CONCRETE STAIRSTEEL RAILINGBRICK CONTROL JOINTHOLLOW METAL FRAME AND DOORBRICK 1 SOLDIER COURSEBRICK 1ALUMINUM CURTAIN WALL SYSTEMPREFINISHED METAL COPINGBRICK CONTROL JOINTCAFETERIA LEVEL104'-0"T.O. MASONRY119'-8"PREFINISHED METAL COPINGBRICK 1 SOLIDER COURSEBRICK 1CAFETERIA LEVEL104'-0"T.O. MASONRY119'-8"PREFINISHED RAINSCREEN PANELPREFINISHED METAL COPINGALUMINUM CURTAIN WALL SYSTEM PREFINISHED METAL COPINGBRICK 1 SOLDIER COURSEBRICK 1MAIN LEVEL100'-0"ENTRY LEVEL104'-0"SECOND LEVEL109'-4"T.O. MASONRY123'-3"ALUMINUM CURTAIN WALL SYSTEMBRICK 1 SOLDIER COURSEBRICK 1BRICK CONTROL JOINTPREFINISHED METAL COPINGPREFINISHED METAL COPINGALUMINUM CURTAIN WALL SYSTEMBRICK 1 SOLDIER COURSEBRICK 1ALUMINUM CURTAIN WALL SYSTEMALUMINUM CURTAIN WALL SYSTEMPREFINISHED METAL COPINGBRICK 1 SOLDIER COURSEBRICK 1ALUMINUM STOREFRONT SYSTEMPREFINISHED RAINSCREEN PANELPREFINIISHED METAL PANEL BRICK 1PREFINISHED RAINSCREEN PANELMAIN LEVEL100'-0"ENTRY LEVEL104'-0"SECOND LEVEL109'-4"T.O. MASONRY123'-3"ALUMINUM CURTAIN WALL SYSTEMPREFINISHED METAL COPINGBRICK 1 SOLDIER COURSEBRICK 1ALUMINUM CURTAIN WALL SYSTEMBRICK 1BRICK 1 SOLDIER COURSEPREFINISHED METAL PANELALUMINUM CURTAIN WALL SYSTEMMAIN LEVEL100'-0"ENTRY LEVEL104'-0"SECOND LEVEL109'-4"T.O. MASONRY123'-3"BRICK 1BRICK 1 SOLDIER COURSEPREFINISHED METAL COPINGANODIZED ALUMINUM DOORALUMINUM STOREFRONT SYSTEMALUMINUM CURTAIN WALL SYSTEMPREFINISHED METAL COPINGBRICK 1 SOLDIER COURSEBRICK 1PREFINISHED RAINSCREEN PANELENTRY LEVEL104'-0"SECOND LEVEL109'-4"T.O. MASONRY123'-3"EXISTING BUILDINGVALENTINE HILLS ELEMENTARYBUILDING ADDITIONBUILDING ADDITIONE1A1E2A1E5A1D1A1D4A1B1A1B3A1FEDCBA12345678AMNNorthCheck:Drawn:Date:Comm:License Number:I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensedunder the laws of the State ofScale:Date501 South Eighth StreetMinneapolis, MN 55404krausanderson.com | 612 332 72818/30/2019 3:39:57 PMC:\Users\cjohnson\Documents\172267_VALENTINE HILLS ES 2019 ADD & RENO_cjohnson@woldae.com.rvtAs indicatedCentral: \\Wae-srv-mn.woldae.com\StPaul\ISD621\ES_VALENTINE HILLS\172267 - 2019 Additions &Renovations\02_ARCH\Revit\172267_VALENTINE HILLS ES 2019 ADD & RENO.rvtA1EXTERIORELEVATIONSNOT FOR CONSTRUCTIONCheckerAuthorIssue Date172267Reg StateIssue DateArch NameArch NumARCHITECTISD #621: MOUNDSVIEW PUBLIC SCHOOLSVALENTINE HILLSELEMENTARY 2019ADDITIONS ANDRENOVATIONS4570 VICTORIA STREET NShoreview, MN 551261770 W COUNTY ROAD E2ARDEN HILLS, MN 55112RevisionsDescription Date Num01/8" = 1'-0"EXTERIOR ELEVATION - AREA 'A' NORTHE16'12'01/8" = 1'-0"EXTERIOR ELEVATION - AREA 'A' WESTE26' 12'01/8" = 1'-0"EXTERIOR ELEVATION - AREA 'A' SOUTHE56' 12'01/8" = 1'-0"EXTERIOR ELEVATIONS - AREA 'C' WESTD16' 12'01/8" = 1'-0"EXTERIOR ELEVATION - AREA 'C' SOUTHD46' 12'01/8" = 1'-0"EXTERIOR ELEVATION - AREA 'C' EASTB16' 12'01/8" = 1'-0"EXTERIOR ELEVATION - AREA 'C' NORTHEASTB36' 12'PREFINISHED METAL COPINGBRICK 1 SOLDIER COURSEPREFINISHED METAL COPINGSTEEL RAILINGCONCRETE STAIRBRICK CONTROL JOINTELEVATION KEY PLAN DN CAFETERIA VEST DISH STOR STOR CIRC ELEC KITCHEN DRY STORAGE REF FRZ BOILER CHILLER STOR STOR CIRC CIRC OFFICE OFFICE COPY GYM P.E. OFFICE STOR STOR STOR VESTADDITIONEXISTINGADDITIONEXISTING 39'-4"11'-8"22'-9"10'-0" 10'-6" 5'-6" 6'-0" 10'-0" F E D C B A 1 2 3 4 5 6 7 8 A MN NorthCheck: Drawn: Date: Comm: License Number: I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed under the laws of the State of Scale: Date 501 South Eighth Street Minneapolis, MN 55404 krausanderson.com | 612 332 7281 8/30/2019 12:26:31 PMC:\Users\jnkhata\Documents\172267_VALENTINE HILLS ES 2019 ADD & RENO_jnkhata.rvt1/8" = 1'-0"Central: \\Wae-srv-mn.woldae.com\StPaul\ISD621\ES_VALENTINE HILLS\172267 - 2019 Additions &Renovations\02_ARCH\Revit\172267_VALENTINE HILLS ES 2019 ADD & RENO.rvtA2 FLOOR PLAN - ADDITION / RENOVATION - AREA 'A' NOT FOR CONSTRUCTION Checker Author Issue Date 172267 Reg State Issue Date Arch Name Arch Num ARCHITECT ISD #621: MOUNDS VIEW PUBLIC SCHOOLS VALENTINE HILLS ELEMENTARY 2019 ADDITIONS AND RENOVATIONS 4570 VICTORIA STREET N Shoreview, MN 55126 1770 W COUNTY ROAD E2 ARDEN HILLS, MN 55112 Revisions Description Date Num 0 1/8" = 1'-0" MAIN LEVEL - AREA 'A'A3 6'12' UP DN ??????CLASSROOM FLEX CIRC GEN ED GEN ED GEN ED FLEX GEN ED GEN ED GEN ED ENTRY VEST CIRC COAT STORAGE CLASSROOM CLASSROOM GIRLS BOYS CIRCADDITIONEXISTING ADDITIONEXISTING29'-4"27'-4" 11'-4"16'-0" 6'-8" 13'-10 1/8" 6 '-1 0 3 /8 "2 2 '-1 5 /8 "17' -3 3/8" F E D C B A 1 2 3 4 5 6 7 8 A MN NorthCheck: Drawn: Date: Comm: License Number: I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed under the laws of the State of Scale: Date 501 South Eighth Street Minneapolis, MN 55404 krausanderson.com | 612 332 7281 8/30/2019 12:26:32 PMC:\Users\jnkhata\Documents\172267_VALENTINE HILLS ES 2019 ADD & RENO_jnkhata.rvt1/8" = 1'-0"Central: \\Wae-srv-mn.woldae.com\StPaul\ISD621\ES_VALENTINE HILLS\172267 - 2019 Additions &Renovations\02_ARCH\Revit\172267_VALENTINE HILLS ES 2019 ADD & RENO.rvtA3 FLOOR PLAN - ADDITION / RENOVATION - AREA 'C' NOT FOR CONSTRUCTION Checker Author Issue Date 172267 Reg State Issue Date Arch Name Arch Num ARCHITECT ISD #621: MOUNDS VIEW PUBLIC SCHOOLS VALENTINE HILLS ELEMENTARY 2019 ADDITIONS AND RENOVATIONS 4570 VICTORIA STREET N Shoreview, MN 55126 1770 W COUNTY ROAD E2 ARDEN HILLS, MN 55112 Revisions Description Date Num 0 1/8" = 1'-0" MAIN LEVEL - AREA 'C'A2 6' 12' VALENTINE HILLS ELEMENTARY SCHOOL PARTIAL SITE LIGTING PLANDesignerDate8/30/2019ScaleNot to ScaleDrawing No.Summary1 of 11.71.81.31.72.02.12.12.31.42.54.53.41.91.71.93.94.21.91.42.81.51.29.61.81.64.62.34.13.910.2 3.02.61.61.91.21.4 0.9 2.8 5.48.015.47.1 8.414.116.53.91.82.43.10.720.5C-1C-2C-3A (new)-1B (Ex)-1B (Ex)-2B (Ex)-3B (Ex)-4F (Ex)-1F (Ex)-2F (Ex)-3G (EX)-1G (EX)-2A (new)-2A (new)-3Plan View - AStatisticsDescriptionSymbolAvg Max MinMax/MinAvg/MinSOUTH5.4 fc 20.5 fc 0.7 fc 29.3:1 7.7:1WEST2.6 fc 9.6 fc 1.2 fc 8.0:1 2.2:1ScheduleSymbol Label Image QTY Catalog Number DescriptionLampNumberLampsLumensper LampLLF Wattage Polar PlotA(new)3 WST LED P2 40K VFMVOLT DS VGWST LED, Performance package 2, 4000 K,visual comfort forward throw, MVOLT, dualswitching, vandal guardLED 1 3175 0.95 26B(Ex)4 TWF1 2/42TRT CONTOUR SERIES BUILDING MOUNTEDWALLPACK WITH VERTICAL LAMP ANDGLASS LENSTWO 42-WATT COMPACTFLUORESCENT TRIPLE TUBE,VERTICAL BASE UP POS.2 3200 0.95 84C3 EVO 40/10 6AR WD LSS 4000K, 1000LM, CRI80, 6IN CLEAR, WIDEDIST, SEMI-SPECLED 1 1073 0.95 11.75F(Ex)3 KAC 250S DP CONTOUR SERIES ARM-MOUNT LUMINAIREWITH DROP PRISMATIC LENSONE 250-WATT CLEAR ET-18HIGH PRESSURE SODIUM,HORIZONTAL POSITION1 29000 0.7 310G(EX)2 KSF2 400S R5S Specification Area Luminaire, 400W HighPressure Sodium, R5 Square Reflector, FullCutoff MEETS THE 'NIGHTTIME FRIENDLY'CRITERIAONE 400-WATT CLEAR ET-18HIGH PRESSURE SODIUM,HORIZONTAL POSITION.1 50000 0.7 468Note1. Light Fixtures Type 'A' and 'C' are proposed new lights to be used.2.Light Fixtures 'B', 'F' and 'G' are existing. There are no available IES files for these fixtures. Thisare approximate equals. EXISTING TRASH LOCATIONNOTES:LEGENDREFERENCE KEY TO SITE DETAILS DETAIL I.D NUMBER (TOP) DETAIL SHEET NUMBER (BOTTOM)PROPOSED CONCRETE WALKPROPOSED LIGHT DUTY BITUMINOUS PAVEMENTPROPOSED HEAVY DUTY BITUMINOUS PAVEMENTPROPOSED BOLLARDPROPOSED MANHOLE (MH)PROPOSED CATCH BASIN (CB)PROPOSED FLARED END SECTION (FES)PROPOSED BUILDING STOOP - REFER TO ARCHITECTURAL PLANSPROPOSED LIGHT POLE - REFER TO ELECTRICAL PLANSPROPERTY LINEADDITIONAL EVENT PARKING1.REFER TO SHEET CXXX, XXXXXXX, FOR GENERAL NOTES.2.CHECK ALL PLAN AND DETAIL DIMENSIONS AND VERIFY SAME BEFORE FIELD LAYOUT.3.ALL DISTURBED AREAS OUTSIDE THE BUILDING PAD WHICH ARE NOT DESIGNATED TO BEPAVED SHALL RECEIVE AT LEAST 6" OF TOPSOIL AND SHALL BE SODDED OR SEEDED.4.WHERE NEW SOD MEETS EXISTING TURF, EXISTING TURF EDGE SHALL BE CUT TO ALLOW FORA CONSISTENT, UNIFORM STRAIGHT EDGE. JAGGED OR UNEVEN EDGES WILL NOT BEACCEPTABLE. REMOVE TOPSOIL AT JOINT BETWEEN EXISTING AND NEW AS REQUIRED TOALLOW NEW SOD SURFACE TO BE FLUSH WITH EXISTING.5.FAILURE OF TURF DEVELOPMENT: IN THE EVENT THE CONTRACTOR FAILS TO PROVIDE ANACCEPTABLE TURF, THE CONTRACTOR SHALL RE-SOD OR RE-SEED ALL APPLICABLE AREAS,AT NO ADDITIONAL COST TO THE OWNER, TO THE SATISFACTION OF THE ENGINEER.EXISTING PARKING COUNTS: 87 TOTAL STALLSPROPOSED PARKING COUNTS (81 TOTAL CAR STALLS):STAFF/VISITOR PARKING = 77 STALLSBUS PARKING = 11 STALLSADDITIONAL EVENT PARKING = 76 STALLSACCESSIBLE PARKING STALL REQUIREMENTS = 4 STALLSACCESSIBLE PARKING STALLS PROVIDED = 4 STALLSSITE STATISTICS:XXLANDSCAPE ARCHITECTURE SITE PLANNING CIVIL ENGINEERINGANDERSON - JOHNSONASSOCIATES,INC.7575 GOLDEN VALLEY ROAD SUITE 200 MINNEAPOLIS. MN 55427FAX (763) 544-0531 PH (763) 544-7129DateRegistration NumberCheckDrawnDate:CommI hereby certify that this plan, specification or report was prepared byme or under my direct supervision and that I am a duly Licensedunder the laws of the State ofRevisionsDescriptionDateNumScale:NorthSITE OVERALL MAPDAVID A. REY40180CWFDAR1" = 30'C3.11MINNESOTAPROFESSIONAL ENGINEERISD #621: MOUNDS VIEWPUBLIC SCHOOLS4570 VICTORIA STREET NSHOREVIEW, MN 551261770 County Road E2 WArden Hills, Minnesota 55112VALENTINE HILLSELEMENTARYSCHOOL BUILDINGADDITIONS City of Arden Hills Planning Commission Meeting for November 6, 2019 P:\Planning\Planning Cases\2019\19-015 - 3244 Sandeen Road\Memos Reports Page 1 of 6 MEMORANDUM DATE: November 6, 2019 PC Agenda Item 3.B TO: Planning Commission Chair and Commissioners FROM: Joe Hartmann, Associate Planner Mike Mrosla, Community Development Manager/City Planner SUBJECT: Planning Case #19-015 – No Public Hearing Required Applicant: Kell Architects Property Location: 3244 Sandeen Road Request: Variance Requested Action Kell Architects (“The Applicant”) has requested a variance in order to construct a single family residence located at 3244 Sandeen Road (“Subject Property”) on a vacant lot overlooking Lake Johanna. Background 1. Overview of Request City Staff received a land use application for a request to build a new single family dwelling at the subject property which is currently a vacant lot in the R-2, Single and Two Family Residential District. The Applicant is requesting a variance to build a single-family detached dwelling on the subject property adjacent to Lake Johanna. The previous owners demolished the existing house on 3244 Sandeen Road prior to selling the subject property to the current owner. The original house was built with a five (5) foot variance from the front yard setback, allowing it to be built thirty-five (35) feet from the front yard property line due to lot encumbrances. The Applicant is requesting a thirty (30) foot front yard setback from the property line and flexibility in the FAR requirements via variance. The subject property is a legal non-conforming lot with encumbrances. The subject parcel is approximately 50 feet in width and is 9,400 square feet. The R2 district standards require a minimum lot width of 85 feet and 11,000 square feet. In addition, a bluff is located on the Lake Johanna side of the subject property. The zoning code definition of a bluff is provided on the next page. City of Arden Hills Planning Commission Meeting for November 6, 2019 P:\Planning\Planning Cases\2019\19-015 - 3244 Sandeen Road\Memos Reports Page 2 of 6 Bluff - A topographic feature such as a hill, cliff, or embankment having the following characteristics (an area with an average slope of less than 18 percent over a distance for 50 feet or more shall not be considered part of the bluff): ∙ Part or all of the feature is located in a shoreland area; ∙ The slope rises at least 25 feet above the ordinary high water level of the water body; ∙ The grade of the slope from the toe of the bluff to a point 25 feet or more above the ordinary high water level averages 30 percent or greater; and ∙ The slope must drain toward the waterbody. The subject property has a grade of slope of 56% from the toe of the bluff to a point 25 feet or more above the ordinary high. Atop the bluff is the bluff impact zone. A bluff impact zone is established for preservation and management of shoreland vegetation and soils, and all structural development is excluded from this zone, except for stairways, lifts and landings. The bluff impact zone has a required setback of 20 feet from the top of a bluff and shown on the image below. Plan Evaluation Chapter 13, Zoning Regulations Review 1. District Provisions (R-2 Single Family Residential District) – Section 1320 Lot Size and Dimensions The Subject Property is located on a 0.22 acre lot approximately 9,400 square feet in size. The proposed subject property is on a non-conforming lot given the R-2 District's 11,000 square foot minimum lot size requirement. In addition, the lot features a bluff on the north size of the property that further restricts the buildable area allowed under City Code. Lots within an R-2 District have a minimum length and width requirement of 85 feet and 120 feet. The subject property meets the length requirement for a parcel in the R-2 district, which is approximately 185 feet long, but the lot is only about 50 feet wide and does not meet the minimum width requirement. City of Arden Hills Planning Commission Meeting for November 6, 2019 P:\Planning\Planning Cases\2019\19-015 - 3244 Sandeen Road\Memos Reports Page 3 of 6 Structure Setbacks - Flexibility Requested In the R-2 District, the minimum front and rear setback requirements for a property are forty (40) feet and thirty (30) feet, respectively. The minimum side yard setbacks must meet a combined twenty-five (25) feet or more. As previously stated, the applicants are requesting flexibility to encroach ten (10) feet into the front yard for a thirty (30) foot front yard setback. Otherwise, the property would meet setback requirements for the R-2 district. Moving the house forward ten (10) feet will also preserve existing lake views for both neighboring homes. It would also decrease the size of the driveway required to get to the house, thus decreasing the amount of impervious cover required for the project. Lot Coverage The proposed footprint of the structure is approximately 2,036 square feet, which meets the R-2 regulations for maximum structure size on a 9,400 square foot lot. The total impervious coverage for the Subject Property would be 2,776 square feet, or 29.5%, which is below the total impervious coverage maximum and 70.5% of the lot remains undeveloped as landscaped area. Given the lot is 9,400 square feet, the proposed total structure encompasses 21.7% of the lot, which is below the maximum. The Applicant is proposing a two-story single family home above grade and then utilizing the existing grade onsite to construct a garage and basement built into the hillside. However, the Applicant would like to have the flexibility to have a FAR of 3,400 square feet due to the property owners having a unique special needs programming requirements for their child. The proposed Floor Area Ratio (FAR) would encompass 3,400 square feet, or 36 percent. A FAR of 3,400 square feet would encompass 30 percent of a standard 11,000 square foot lot which meets the R-2 zoning district FAR requirements. 2. Variance Requirements – Section 1355.04, Subd. 4 1. Purpose and Intent. The variance request shall comply with the purpose and intent of the provisions of the City’s Zoning Regulations and with the policies of the City’s Comprehensive Plan. The variance request for 3244 Sandeen Road would comply with the purpose and intent of the R-2 Zoning District and with the policies within the City’s Comprehensive Plan. 2. Practical Difficulties. The applicant for a variance shall establish that there are practical difficulties in complying with the provisions of the Arden Hills Zoning Regulations. The term “Practical Difficulties” as used in the granting of a variance means: a. Reasonable Use. The property owner proposes to use the property in a reasonable manner not permitted by the Zoning Ordinance. A single family home is a reasonable use of the Subject Property in the R-2 Zoning District. City of Arden Hills Planning Commission Meeting for November 6, 2019 P:\Planning\Planning Cases\2019\19-015 - 3244 Sandeen Road\Memos Reports Page 4 of 6 b. Unique Circumstances. The plight of the property owner is due to circumstances unique to the property not created by the landowner. The subject property is a non-conforming lot. The existing lot width is approximately 50 feet and the lot area is 9,400 square feet. The zoning district requires a minimum lot width of 85 feet and minimum lot area of 11,000 square feet. The existing topography is uneven sloping up towards the lake and then a bluff is located on the lakeside of the property. These circumstances are unique to the property 3244 Sandeen Road. c. Character of Neighborhood. The variance, if granted, will not alter the essential character of the neighborhood. The proposed dwelling will not alter the character of the neighborhood and is consistent with the other dwellings in the neighborhood. 3. Economic Consideration. Economic consideration alone does not constitute a practical difficulty. The proposed variance is not based on economic consideration. 4. Access to Sunlight. Inadequate access to direct sunlight for solar energy systems shall be considered a practical difficulty. A solar energy system is not proposed. Additional Review Residential Building Inspector The Residential Building Inspector has reviewed the plans and had no additional comments at this time. A Building Permit will be required prior to any construction taking place. Public Works Director/City Engineer The Public Works Director/City Engineer has reviewed the plans and had no additional comments at this time. Findings of Fact The Planning Commission must make a finding as to whether or not the proposed application would adversely affect the surrounding neighborhood or the community as a whole based on the aforementioned factors. Staff offers the following findings for consideration: General Findings: 1. City Staff received a land use application for a request to build a new single family dwelling at the Subject Property 3244 Sandeen Road City of Arden Hills Planning Commission Meeting for November 6, 2019 P:\Planning\Planning Cases\2019\19-015 - 3244 Sandeen Road\Memos Reports Page 5 of 6 2. The Subject Property is currently a vacant lot in the R-2 Single and Two Family Residential District that is non-conforming given the R-2 District's minimum width and area requirements. 3. The proposed increase FAR of 3,400 square feet would be 30 percent on a standard 11,000 square foot lot and would constant with the R-2 zoning district requirements. 4. The Applicant is requesting a variance to build a single-family detached dwelling with a 30-foot front yard setback instead of 40 feet required by ordinance. 5. If granted a variance, the proposed property would meet all other minimum setback requirements for the R-2 District, as indicated by the plans submitted by the Applicant. 6. The proposed development would not encroach on the bluff or any flood plains, wetlands, or easements. 7. The proposed development is not expected to impact any significant trees on the property. Variance Findings: 1. The variance request would comply with the purpose and intent of the R-2 Zoning District and with the policies within the City’s Comprehensive Plan. 2. The proposed addition is a reasonable use of the property. 3. The proposed addition will not alter the character of the neighborhood and is consistent with the other dwellings in the neighborhood. Staff do not believe that granting a variance would negatively impact neighboring properties. 4. The proposed variance is not based on economic consideration. 5. A solar energy system is not proposed. However, the proposed addition would not impact the ability to construct a solar energy system onsite or on an adjoining property. Options and Motion Language Staff has provided the following options and motion language for this case. The Planning Commission should consider providing additional findings of fact as part of the motion to support their recommendation for approval or denial. • Recommend Approval with Conditions: Motion to recommend approval of Planning Case 19-015 for a Variance at 3244 Sandeen Road, based on the findings of fact and the submitted plans, as amended by the three (3) conditions in the October 9, 2019 Report to the Planning Commission: 1. The project shall be completed in accordance with the plans submitted as amended by the conditions of approval. Any significant changes to these plans, as determined by the City Planner, shall require review and approval by the Planning Commission and City Council. 2. A Building Permit shall be issued prior to commencement of construction. 3. The structure shall conform to all other regulations in the City Code. • Recommend Approval as Submitted: Motion to recommend approval of Planning Case 19- 015 for a Variance at 3244 Sandeen Road, based on the findings of fact and the submitted plans in the May 9, 2018 Report to the Planning Commission. City of Arden Hills Planning Commission Meeting for November 6, 2019 P:\Planning\Planning Cases\2019\19-015 - 3244 Sandeen Road\Memos Reports Page 6 of 6 • Recommend Denial: Motion to recommend denial Planning Case 19-015 for a Variance at 3244 Sandeen Road, based on the following findings: findings to deny should specifically reference the reasons for denial and why those reasons cannot be mitigated. • Table: Motion to table Planning Case 19-015 for a Variance at 3244 Sandeen Road: a specific reason and information request should be included with a motion to table. Notice Although a variance does not require a public hearing, a public meeting notice was prepared by the City and mailed to properties within 500 feet of the subject property. Public Comments Staff received comments in regards to this proposal from one resident. Deadline for Agency Actions The City of Arden Hills received the completed application for this request on October 21, 2019. Pursuant to Minnesota State Statute, the City must act on this request by November 8, 2019 (60 days), unless the City provides the petitioner with written reasons for an additional 60-day review period. With consent of the applicant, the City may extend the review period beyond the initial 120 days. Attachments A. Land Use Application B. Location Map C. Drawings D. Submitted Plans E. Variance Request Letter Disclaimer: This m ap is intended for reference purposes only and is not a legally recorded map or survey. The City of Arden Hills shall not be liable for any damages or claims that arise due to accuracy,availability, use or misuse of the inform ation herein pursuant to MNStatute 466.03 Subd 21. Location Map Lake Johanna BoulevardSandeen Road ± Park and Open Space Subject Parcel §¨¦35W §¨¦694 £¤10 821 Raymond Ave., Ste. 400 St. Paul, Minnesota 55114 612-812-5687 www.kellarchitects.com Date: This drawing is provided as an instrument of Service by Kell Architects and is intended for use on this project only. Kell Architects is the author and the owner of these instruments and retains all common law statutory and other reserved rights, including copyright. Any reproduction, use or disclosure of the designs, arrangements or information contained herein without the prior written consent of Kell Architects is strictly prohibited. © Kell Architects 2019 Variance - 31 Oct 2019 3244 SANDEEN ROAD70'-0"30'-0"UP3 CAR GARAGE LOWER LEVEL = 534.92 SQ.FT. HOUSE TOTAL = 3400.00 SQ.FT. BATH STORAGE PHYSICAL THERAPY MECHANICAL SCALE: 1/8" = 1'-0" 1 PLAN - lower level study 01 821 Raymond Ave., Ste. 400 St. Paul, Minnesota 55114 612-812-5687 www.kellarchitects.com Date: This drawing is provided as an instrument of Service by Kell Architects and is intended for use on this project only. Kell Architects is the author and the owner of these instruments and retains all common law statutory and other reserved rights, including copyright. Any reproduction, use or disclosure of the designs, arrangements or information contained herein without the prior written consent of Kell Architects is strictly prohibited. © Kell Architects 2019 Variance - 31 Oct 2019 3244 SANDEEN ROAD52'-0"30'-0"DOWNUPMUDROOM ENTRYBATH KITCHEN DINING DECK SCREENED PORCH FAMILY ROOM MAIN LEVEL = 1305.08 SQ.FT. HOUSE TOTAL = 3400.00 SQ.FT. OFFICEBEDROOM SCALE: 1/8" = 1'-0" 1 PLAN - main level study 02 821 Raymond Ave., Ste. 400 St. Paul, Minnesota 55114 612-812-5687 www.kellarchitects.com Date: This drawing is provided as an instrument of Service by Kell Architects and is intended for use on this project only. Kell Architects is the author and the owner of these instruments and retains all common law statutory and other reserved rights, including copyright. Any reproduction, use or disclosure of the designs, arrangements or information contained herein without the prior written consent of Kell Architects is strictly prohibited. © Kell Architects 2019 Variance - 31 Oct 2019 3244 SANDEEN ROAD 30'-0"52'-0"DOWNBEDROOM BATH BEDROOM BEDROOM BATH BEDROOM CLOSET CLOSET CLOSET HIS CLOSET LINENLAUNDRY HER CLOSET COUPLE'S BATH COUPLE'S BEDROOM UPPER LEVEL = 1560.00 SQ.FT. HOUSE TOTAL = 3400.00 SQ.FT. SCALE: 1/8" = 1'-0" 1 PLAN - upper level study 03 821 Raymond Ave., Ste. 400 St. Paul, Minnesota 55114 612-812-5687 www.kellarchitects.com Date: This drawing is provided as an instrument of Service by Kell Architects and is intended for use on this project only. Kell Architects is the author and the owner of these instruments and retains all common law statutory and other reserved rights, including copyright. Any reproduction, use or disclosure of the designs, arrangements or information contained herein without the prior written consent of Kell Architects is strictly prohibited. © Kell Architects 2019 3244 SANDEEN ROAD Variance - 31 Oct 201934'-8"30'-0" 898.25 879LOWEST GRADE TOMID-POINT @ GABLEFRONT YARD VARIANCE REQUESTED @ ROAD @ LAKE SCALE: 1/16" = 1'-0" 1 SITE SECTION - study 04 31 October 2019 DESCRIPTION OF REQUEST – 3244 SANDEEN ROAD The applicant is requesting a variance from the front yard setback and Floor Area Ratio requirements for the property located at 3244 Sandeen Road. 3244 Sandeen Road is located in the R-2 Single and Two Family Residential District (with Shoreland Overlay) on the southwest corner of Lake Johanna. At 9,400.25 square feet, 3244 is a non-conforming lot size given the R-2 District’s 11,000 square foot minimum lot size requirement. The previous property owner removed the previous house on 3244 prior to selling the property to the current property owner. The original house was built with a 10’ variance from the front yard setback, allowing it to be built 30’ from the front yard property line. This application requests reinstatement of a 30’ front yard setback. This setback will allow the new home to be setback from the lake ten additional feet. Moving the house back 10’ will preserve existing lake views for both neighboring homes. It will also decrease the size of the driveway required to get to the house, thus decreasing the amount of impervious cover required for the project. This application also requests a variance from the F.A.R. The new property owners have some unique special needs programming requirements that require a house size unable to fit within the F.A.R. on this non-conforming lot. Initial square footage studies for the applicant suggest a required 3,400 square foot home (see attached plans) to meet their needs. Approximately, 534 of this total square footage will be below grade and not perceivable to the general public. So as it goes towards mass and scale, the house will actually feel closer to the 2,820 square feet that are above grade and allowed given the non-conforming lot square footage and F.A.R. requirement. Also, given the immediate neighboring property to the northwest would be allowed to build a 6,272 square foot house on their 20,908 square foot lot, and the immediate neighboring property to the southeast would be allowed to build a 6,925 square foot house on their 23,086 square foot lot, we submit that our requested variance from the F.A.R. is a reasonable request and will result in a home that will fit well within the immediate neighborhood both now and into the future.