Laserfiche WebLink
<br />Effective: 2/11/77 <br />City ofCenten1lle Ord. #30 <br /> <br />iustall the house sewer by exposing the wye at the sewer main or the service stub at the property <br />line, connecting to that wye or service stub at"'1d shall lay the house sewer pipe from the wye or <br />service stub to the building. <br />The City will assume no responsibility for extra charges as a result of such misplaced <br />cOI'..nections unless it is notified before any work is done and has had an inspection made by its <br />representative to confirm the condition and to authorize extra work. <br />Existing building senice lines or systems may require replacement. Such lines claimed to be in <br />good condition and approved material shall be subjec(to an air test or other suitable tests <br />approved by the City Engineer and or Plumbing Inspector. Any system will be subject to <br />retestii"lg. Cost of testing shall be paid by the o\Vner. Any system failing to meet a satisfactory <br />test shall be replaced or repaired to the satisfaction ofthe City Engineer and or Plumbing <br />Inspector. <br />No connection of any building sewer service line shall be made by any person other than an <br />employee of the City of Centerville, a licensed sewer installer or a plumber licensed by the State <br />of Minnesota and all such connections shall be made under drj conditions, either naturally <br />occurring or by dewatering and under supervision of the Plumbing Inspector. <br /> <br />SECTION 13. ABNOR1vIAL AJ'ID PROHIBITED DISCHA..ttGES. <br />Abnormal strength and volumes shall be classified as a special discharge in comparison to domestic <br />wastes and shall be treated on a special basis as to rates and are subject to review by the City <br />Council. <br />It shall be unlawful for any owner, occupant or user of any premises to direct or discharge prohibited <br />elements or materials into the sanitary sewer system of the City ofCenterville, said prohibited <br />elements or materials being defined herein. <br />1. Storm Water. No storm water, surface water, ground water, or run-off, subsurface drainage, <br />cooling water or unpolluted industrial process waters shall be discharged or caused to be <br />discharged into said sanitary sewer system. <br />2. Roof and Surface Water. No roof or surface water drains shall be connected or directed to drain <br />into the sanitary sewer system. <br />3. Al'1Y gasoline, benzene, naptha, fuel oil, or other flammable or explosive liquid, solid or gas. <br />4. iilly garbage that has not been properly shredded. <br />5. A..nyashes, cinders, sand, mud, straw, shavings, metal, glass, rags, feathers, tar, plastics, wood, <br />paunch man.ure, or any other solid or viscous substance capable of causmg obstmction to the <br />flow in sewers or other interference with the proper operation ofthe sewage works. <br />6. Any waters or wastes having ph lower than 6.0 or higher than 9.0 or having any other property to <br />corrode or abrade, cause materials to be deposited, or attached to the walls of the sewer system, <br />or having any other property capable of causing damage or hazard to structures, equipment at,d <br />personnel of the sewage works. <br />7. Any "vaters or waste containing a toxic, poisonous or radioactive substai'1Ce in sufficient quantity <br />to injure or interfere 'With any sewage treatment process, constitute a hazard to hlL.'TIanS or <br />arm:nals or create any hazard in the sewage treatment plant. <br />8. Any waters or wastes containing suspended so.lids of such character and quantity that unusual <br />attention or expense is required to handle such materials at the sewage treatment plant. <br />9. .A.Jly noxious or malodorous gas or substance capable of creating a public nuisance. <br />10. In addition to the above numbered items, all discharges must be in accordance with Metro Sewer <br />Board booklet "Sewage and Waste Control Rules and Regulations for Metro Disposal System". <br /> <br />Page 6 of9 <br />