<br />5.2 Placement, Design, and Height of Structures. <br /> <br />5.21 Placement of Structures on Lots. When more than one setback applies to a site, structures <br />and facilities must be located to meet all setbacks. Where structures exist on the adjoining lots on <br />both sides of a proposed building site, structure setbacks may be altered without a variance to <br />conform to the adjoining setbacks from the ordinary high water level, provided the proposed <br />building site is not located in a shore impact zone or in a bluff impact zone. Structures shall be <br />located as follows. <br /> <br />A. Structure and On-site Sewage System Setbacks (in feet) from Ordinary High Water <br />Level* . <br /> <br /> Setbacks* <br />Classes of <br />Public Structures Sewage Treatment <br />Waters Unsewered Sewered System <br />Lakes <br />Natural <br />Environment 150 150 150 <br />Recreational <br />Development 100 75 75 <br />General <br />Development 75 50 50 <br />Rivers <br />Remote 200 200 150 <br />Forested and <br />Transition 150 ISO 100 <br />Agriculture, <br />Urban, and <br />Tributary 100 50 75 <br />*One water-oriented accessory structure designed in accordance with Section 5.22 of this <br />ordinance may be set back a minimum distance often (10) feet from the ordinary high water level. <br /> <br />B. Additional Structure Setbacks. The following additional structure setbacks apply, <br />regardless of the classification of the waterbody: <br /> <br />Setback From: <br /> <br />Setback (in feet) <br /> <br />(I) <br /> <br />top of bluff; <br /> <br />30 <br /> <br />(2) <br /> <br />unplatted cemetery; <br /> <br />50 <br />