§60.3 44 CFR Ch.! (10 -1-96 Edition) <br /> or above the base flood level: and (ii) base flood. Wind loading values used <br /> the pile or column foundation and shall be those required by applicable <br /> structure attached thereto is anchored State or local building standards. <br /> to resist flotation, collapse and lateral Such enclosed space shall be useable <br /> movement due to the effects of wind solely for parking of vehicles, building <br /> and water loads acting simultaneously access, or storage. <br /> on all building components. Water (6) Prohibit the use of fill for strut- <br /> loading values used shall be those assn- tural support of buildings within Zones <br /> ciated with the base flood. Wind load- V1-30. VE. and V on the community's <br /> ing values used shall be those required FIRM: <br /> by applicable State or local building (7) Prohibit man -made alteration of <br /> standards. A registered professional en- sand dunes and mangrove stands with - <br /> gineer or architect shall develop or re- in Zones V1-30, VE, and V on the com- <br /> view the structural design, specifics- munity's FIRM which would increase <br /> tions and plans for the construction. potential flood damage. <br /> and shall certify that the design and (8) Require that manufactured homes <br /> methods of construction to be used are placed or substantially improved with- <br /> in accordance with accepted standards in Zones VZT30, V and VE on the com- <br /> of practice for meeting the provisions munity's TERM on sites <br /> of paragraphs (e)(4)(1) and (if) of this (1) Outside of a manufactured home <br /> section. park or subdivision. <br /> (5) Provide that all new construction (ii) In a new manufactured home <br /> and substantial improvements within park or subdivision, <br /> Zones V1-30. VE, and V on the comniu- 011) In an expansion to an existing <br /> nity's FIRM have the space below the manufactured home park or subdivi- <br /> lowest floor either free of obstruction sion, or <br /> or constructed with non- supporting (iv) In an existing manufactured <br /> breakaway walls, open wood lattice- home park or subdivision on which a. <br /> work, or insect screening intended to manufactured home has incurred "sub - <br /> collapse under wind and water loads stantial damage" as the result of a <br /> without causing collapse, displace- flood, <br /> ment, or other structural damage to meet the standards of paragraphs (eX2) <br /> the elevated portion of the building or through (7) of this section and that <br /> supporting foundation system. For the manufactured homes placed or substan- <br /> purposes of this section, a breakway tially improved on other sites in an ex- <br /> wall shall have a design safe loading re isting manufactured home park or sub - <br /> sistance of not less than 10 and no more division within Zones VI-30, V, and VE <br /> than 20 pounds per square foot. Use of on the community's FIRM meet the re- <br /> breakway walls which exceed a design quirements of paragraph (c)(12) of this <br /> safe loading resistance of 20 pounds per section. <br /> square foot (either by design or when (9) Require that recreational vehicles - <br /> so required by local or State codes) placed on sites within Zones V1-30, V, <br /> may be permitted only if a registered and VE on the community's FIRM ei- <br /> Professional engineer or architect cer ther <br /> tifies that the designs proposed meet (i) Be on the site for fewer than 180 <br /> • the following conditions: consecutive days. <br /> (i) Breakaway wall collapse shall re- (ii) Be fully licensed and ready for <br /> sult from a water load less than that highway use, or <br /> which would occur during the base (iii) Meet the requirements in para- <br /> flood; and, graphs (b)(1) and (e) (2) through (7) of <br /> (ii) The elevated portion of the build- this section. <br /> ing and supporting foundation system A recreational vehicle is ready for <br /> shall not be subject to collapse, dis- highway use if it is on its wheels or <br /> placement, or other structural damage jacking system, is attached to the site <br /> due to the effects of wind and water only by quick disconnect type utilities <br /> loads acting simultaneously on all and security devices, and has no per- <br /> building components (structural and manently attached additions. <br /> non - structural). Water loading values (f) When the Director has provided a <br /> used shall be those associated with the notice of final base flood elevations <br /> 240 <br />