Laserfiche WebLink
11. ALL FIELD WIRE ABOVE GRADE OR WITHIN STRUCTURE TO BE INSTALLED IN CONDUIT PER LOCAL CODE. <br />9. CONTROLER SHALL BE GROUNDED PER MANUFACTURER'S SPECIFICATIONS. <br />4. POWER FOR THE IRRIGATION CONTROLLER, PUMP AND OTHER ELECTRICAL COMPONENTS SHALL BE PROVIDED BY OTHERS. <br /> 6.SOME IRRIGATION COMPONENTS AND PIPING ARE SHOWN IN HARDSCAPE AREAS AND OUTSIDE OF PROPERTY <br />1. IRRIGATION POINT OF CONNECTION SHALL BE CAPABLE OF DELIVERING A VARIABLE FLOW RATE OF <br />2. IF THE POINT OF CONNECTION EXCEEDS THE ABOVE PRESSURE REQUIREMENTS, A PRESSURE REGULATOR SHALL BE <br />5. IRRIGATION SYSTEM IS DISPLAYED SCHEMATIC IN NATURE. MINOR FIELD ADJUSTMENTS MAY BE NECESSARY TO <br />8. SYSTEM TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. <br />7. MAINLINE, LATERALS AND CONTROL WIRES SHALL BE INSTALLED INSIDE THE SAME TRENCH WHENEVER POSSIBLE.. <br /> INSTALLED AT THE OWNER'S EXPENSE. PRESSURE REGULATOR SHALL BE SET AT THE PRESSURE RECOMMENED ABOVE. <br /> CONTRACTOR SHALL VERIFY POWER AVAILABLE MEETS THS REQUIREMENTS OF THE COMPONENT'S MANUFACTURER. <br /> ACCOMMODATE FOR LANDSCAPING CHANGES, PLANTING BEDS OR OTHER OBSTRUCTIONS. THESE ADJUSTMENTS <br /> 20 GPM AT A CONSTANT PRESSURE OF 70 PSI DOWNSTREAM OF <br />IRRIGATION SPECIFICATIONS <br />12. ALL UNDERGROUND SPLICES TO UTILIZE 3M DBY, OR KING WATER PROOF SPLICE KITS, DEPENDING ON NUMBER <br /> BACKFLOW PREVENTION DEVICE.POINT OF CONNECTION SHELL BE ABLE TO MAINTAIN THE MAXIMUM FLOW RATE <br /> AND PRESSURE FOR THE DURATION OF AN IRRIGATION CYCLE. CONTRACTOR SHALL VERIFY THESE PARAMETERS PRIOR <br /> TO CONSTRUCTION, AND NOTIFY OWNER'S REPRESENTATIVE AND IRRIGATION CONSULTANT IF THEY CANNOT BE MET. <br /> IF POWER AVAILABLE IS INADQUATE, CONTRACTOR SHALL NOTIFY THE OWNER'S REPRESENTATIVE PRIOR TO CONSTRUCTION. <br /> MAY BE MADE ONLY AFTER NOTIFYING THE OWNER'S REPRESENTATIVE. <br /> LINES TO IMPROVE ON THE READABILITY OF THE IRRIGATION PLAN. ALL COMPONENTS AND PIPING SHALL <br /> BE INSTALLED INSIDE OF THE PROPERTY LINES AND OUTSIDE OF HARDSCAPE AREAS. <br />AND SIZE OF WIRES. ALL SPLICES SHALL BE MADE INSIDE A VALVE BOX. <br />13. DEPTH OF IRRIGATION PIPING 18" ON MAINLINE; 12" ON LATERALS. <br />14. SLEEVING UNDER PAVED AREAS SHALL BE INSTALLED AT A DEPTH OF 24". <br />10. ALL CONTROLLER/DECODER WIRE SHALL BE THE 2-WIRE CABLE SPECIFIED BY THE CONTROLLER MANUFACTURER. <br />3. AN RPZ TYPE BACKFLOW PREVENTION DEVICE SHALL BE INSTALLED IN A MANNER SATISFYING LOCAL CODES AND MANUFACTURER'S RECOMMENDATIONS. <br />15. CONTRACTOR’S RESPONSIBILITY TO VERIFY SCALE & ACCURACY. <br />16. NO SPEC PROVIDED <br />SYMBOL MANUFACTURER/MODEL QTY <br />Hunter MP2000 PROS-04 5 <br />SYMBOL MANUFACTURER/MODEL QTY <br />Hunter PGP-04 1.5 7 <br />Hunter PGP-04 2.5 25 <br />Hunter PGP-04 4.0 3 <br />SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY <br />Hunter PGV-100G 1" <br />1" Plastic Electric Remote Control Valve, for Residential/Light <br />Commercial Use. Female NPT Inlet/Outlet. Globe Configuration, <br />No Flow Control. <br />5 <br />Zurn 975XL 1" <br />Reduced Pressure Backflow device <br />1 <br />Hunter P2C-400 with (01) PCM-300 <br />Light Commercial & Residential Controller, 7-station expanded <br />module controller, 120 VAC, Outdoor/Indoor model <br />1 <br />Hunter WR-CLIK <br />Rain Sensor, install within 1000 ft of controller, in line of sight. <br />22-28 VAC/VDC 100 mA power from timer transformer. Mount as <br />noted. <br />1 <br />Point of Connection 1 1/4" <br />Location TBD <br />1 <br />Irrigation Lateral Line: POLY PIPE 1"952.3 l.f. <br />Irrigation Lateral Line: POLY PIPE 1 1/4"103.0 l.f. <br />Irrigation Mainline: HDPE PE3608 SIDR 19 1 1/4"152.6 l.f. <br />Pipe Sleeve: PVC Class 160 SDR 26 9.3 l.f. <br />K G R <br />1.5 <br />2.5 <br />4.0 <br />Valve Number <br />Valve Flow <br />Valve Size <br />Valve Callout <br /># <br />##" <br />IRRIGATION SCHEDULE BASE <br />SYMBOL MANUFACTURER/MODEL QTY <br />Hunter MP2000 PROS-04 13 <br />SYMBOL MANUFACTURER/MODEL QTY <br />Hunter PGP-04 2.5 2 <br />SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY <br />Hunter PGV-100G 1" <br />1" Plastic Electric Remote Control Valve, for Residential/Light <br />Commercial Use. Female NPT Inlet/Outlet. Globe Configuration, <br />No Flow Control. <br />1 <br />Irrigation Lateral Line: POLY PIPE 1"316.0 l.f. <br />Irrigation Lateral Line: POLY PIPE 1 1/4"124.1 l.f. <br />K G R <br />2.5 <br />Valve Number <br />Valve Flow <br />Valve Size <br />Valve Callout <br /># <br />##" <br />IRRIGATION SCHEDULE ALT <br />KK <br />K <br />K <br />K <br />K <br />K <br />K <br />K <br />K <br />K <br />K <br />K <br />1.5 <br />2.5 <br />2.5 <br />2.52.5 <br />2.5 <br />2.5 <br />2.5 <br />2.5 <br />2.5 <br />2.5 <br />2.5 <br />1.5 <br />1.5 <br />2.5 <br />2.5 <br />2.5 <br />1.5 <br />1.5 <br />1.5 <br />1.5 <br />K <br />K <br />K <br />K <br />K <br />114" <br />2.5 2.5 2.5 <br />2.5 <br />2.5 <br />2.5 <br />2.5 <br />2.5 <br />2.5 <br />4.0 <br />2.5 <br />2.5 <br />2.5 <br />2.5 <br />4.0 <br />4.0 <br />1" <br />1" <br />114" <br />1" <br />1" <br />114" <br />114" <br />1" <br />1" <br />1" <br />114" <br />1" <br />1" <br />114" <br />1" <br />1" <br />ALT <br />BASE <br />Customer Name : <br />Pr <br />o <br />j <br />e <br />c <br />t <br /> <br />N <br />a <br />m <br />e <br /> <br />: <br />Ge <br />m <br /> <br />L <br />a <br />k <br />e <br /> <br />H <br />e <br />r <br />i <br />t <br />a <br />g <br />e <br /> <br />H <br />a <br />l <br />l <br />Design Date: <br />2 <br />3 <br />4 <br />5 <br />6 <br />Description <br />1 <br />Date <br />REVISIONS <br />4/30/24 <br />Drawing Title: <br />Irrigation Plan <br />Drawing Scale:1" = 30' <br />Project Number:HLS-24-21694 <br />Sheet Number: <br />IR-1 <br />NOT FOR <br />CONSTRUCTION <br />Ge <br />m <br /> <br />L <br />a <br />k <br />e <br />, <br /> <br /> <br />M <br />N <br />L A N D S C A P E S U P P L Y G R O U P <br />..\Midwest Title Blocks\HLS_Outdoor SharedVision_logo.jpg <br />A - The irrigation design services provided by HCSG are crafted to assist our <br />customers during the project bidding process. These services are intended to <br />facilitate preliminary planning and are not to be used for construction <br />purposes. We strongly recommend that all designs, estimates, and related <br />documents be reviewed and utilized by professionals who have the requisite <br />experience and educational background in the field. <br />It is important to note that Heritage Commercial Services Group (HCSG), along <br />with our brands, affiliates, vendors, and contractors, assumes no liability for <br />inaccuracies, omissions, errors, or any potential financial losses (including <br />lost income or revenue) arising from the use of our products and services. <br />Our goal is to support your project planning efforts with quality designs and <br />estimates, while emphasizing the need for further professional review and <br />validation. <br />B - HCSG's irrigation design work is specifically tailored for bid preparation <br />and is not intended for use in actual construction projects. For clients <br />requiring detailed construction-ready drawings, our affiliate, WC3, a <br />specialized irrigation design firm within the Heritage Landscape Supply Group, <br />offers professional services. WC3 is equipped to create comprehensive <br />construction drawings, which can be formally stamped and/or submitted for <br />necessary approvals and reviews. <br />Please be aware that HCSG is not to be considered the "Designer/Architect of <br />Record" for any irrigation design projects. Our role is to provide initial <br />design assistance, with the understanding that final design responsibility and <br />verification lie with the hiring of appropriately licensed professionals for <br />construction purposes. <br />0 feet60 <br />1" = 30' <br />30 90 120