Laserfiche WebLink
landscaping plan. - a plan showing 9 trees and 18 shrubs has been submitted. <br />Four of the trees are proposed to be pine. Approximately 1 O' shrubs. are <br />proposed within the Scheuneman Road right of -way. Staff has asked the. <br />applicant to provide two additional trees, as required by the landscaping <br />section of the Consolidated Land. Use Ordinance. <br />In. addition, the building Must be designed by a registered architect; and <br />plans: signed by a P.E. <br />It must be noted that the build.ing.exterior is proposed to be corrugated metal siding. <br />Corrugated siding is not permitted in the. Gateway Zoning ❑istrict. - Polar is <br />requesting a variance from this requirement. They have added a 3' brick wainscoting <br />to. the front of the building. <br />Other ordinance requirements, which must be addressed by the applicant, include: <br />A 25% of the land must be landscaped by grass, shrubbery or trees = an updated <br />landscaping plan has been provided, <br />one. 1.80 square foot minimum landscaped. island. must be provided in the <br />parking lot does the updated plan meet this requirement? <br />the following landscaping must be provided based o.n the site periimeter:. <br />- 11 trees- 30%. of which must be conifers- 9 trees are proposed, 4 .of <br />which are proposed to be pine <br />- 18 shrubs, a minimum of 36" tall - 18 shrubs are now proposed <br />® the landscaped area must.be irrigated - an irrigation detail is not shown on the <br />landscaping plan - there are n.❑ plans to extend sewer and water to the building. <br />No. irrigation is planned for the landscaped areas: The applicant is requesting <br />a variance from this ordinance requirement. A variance from Section 26,4.5 <br />must be approved or in the alternative., the ordinancemay be amended <br />eliminating this requirement. <br />® all refuse/recycling storage must be inside ofth.e building <br />the loading dock and outside mechanical must be screened from the public <br />right-of-way the shrubs planned :for the Scheuneman side of the road will <br />provide some buffering of the larger drive�in door. The loading dock. has very <br />limited screening proposed. Staff suggested that the two additional trees be <br />.placed to.help with the dock screening. <br />No sewer and water is. planned to be extended to the building as no restrooms <br />are proposed <br />The City Engineer has done a preliminary review of the, plan and offers the following <br />comments: <br />plans need to be signed by a P.E_ <br />