Laserfiche WebLink
or choose to take -no. action on the WECS license. If a WECS license is revoked, the WECS and tower must he <br />dismantled and removed. from .the property within-90: days of revocation. <br />244. Code compliance. WECS.installation is not exempt from.the State Building Code and similar safety codes, and all <br />:permits required for the construction and�or. nstaUation.:of WECS components must be obtained. from the Czty's <br />Building Official prior to. commencing work. to 'install. the WECS. <br />24.4.1. Co mpiiance.with state building code. Standard drawings of the structural components of the:wind energy <br />conversion system. and support structures, including base and footings shall be provided along with. engineering <br />data and .calculations to. demonstrate compliance with the structural design :ptovisiods. of the state building <br />code. Drawings and engineering calculations. shall be certified by a Minnesota licensed engineer. <br />24.4.2. Compliance with National Electrical Code.. WECS electrical equipment and connections shall be <br />designed aud.installed in adherence to the National Electrical C0 as. adopted by the city. <br />24,5. Standards. for Siting; Installation and Operation of <br />2.4.5.1. Height The height of a WECS:must co . n1ply Wfth FAA seguiation part.77 "Objects Affecting Navigable <br />Air Space. and/or MND OT Rule 14, MCAR 1.3:a45' Criteria for iJeCernvning obstruction to Air Navigation . <br />24.5.2, Setback. WECS. towers: shall beset baelt. from the closest property line at least one foot for every one <br />foot of the system's total extended:height. Na;part of a WECS (including' gizy; ryire anchors) shall be located <br />within.or above any required front, side or rear yard setback:; <br />24.5.3: Rotor clearance. At iiistallatio ; the bottom o£ `tt e WECS blade diameter shall have a minimum of 5 <br />feet or clearance over any structure:.' �iridud ng above^grounq utilities) or tree within a 200-foot .radius. of the <br />WECS tower. The .property:owner is.`zesporisibu for ensuring that trees and .other vegetation o not encroach <br />onthe minimum rotox.,cleararice:after'the system is=installed. <br />CS shall lie!; ''u g_i wl.th con ol.e ui merit. to prevent dangerous operation in <br />24.5.4. Rotor safety'Each WE. q.<,,PP.,.<;.;:;. p. <br />high wind and`tio. allow the. turWhe to be slowed``q stopped: in`ari :emergency. <br />24.5.5. Tower accessTo;pret unauthoxized clunbing, WECS towers must comply -with. one of the. following <br />Tower-dibabing apparatus shall. riot be located within 12.feet of.the ground. <br />A locked ant limb device'shali be installed. on the tower. <br />being climbed shall be enclosed by -a locked, protective fence at least six feet <br />.24.5.6, :Component c.rtifteation. Each electrical component of the-WECS must. be certified by Underwriters. <br />Laboratories, Inc: The?' ra all WECS system must either be certified or pending certification by the Small: Wind <br />Certification Council as compliant with the American Wind Energy Association's Small Wind Turbine <br />,Performance and Safety Standard. <br />24.5.7..Lightning protection. Each WECS shall be grounded to protect against natural lightning strikes in <br />conformance with the National Electrical Code as adopted by the city. <br />24.5.8. Signs. Each WECS shall have one sign, not to exceed two square feet, posted at. -the base of the tower. <br />and said. sign shall contain. the following information. <br />4 High. voltage warning,. if a. component of the WECS is "high voltage" under the National Electrical <br />Code. <br />4 Manufacturer's :name. <br />Updated March 1 4,. 2d 17 Gem Lake Consolidated -Land .Use Ordinance —. Page .139 <br />