Laserfiche WebLink
Four-sided Design: <br />G. Building design shall provide consistent <br />architectural treatment on all building walls. All sides of <br />a building must display compatible materials, although <br />decorative elements and materials may be concentrated <br />on street-facing facades. All facades shall contain window <br /> is standard may be waived by the Community <br />Development Department for uses that include elements <br />such as service bays on one or more facades. <br />Maximum Building Length: <br />H. Building length parallel to the <br />Four-sided building design <br />primary abutting street shall not exceed 200 feet without a <br />visual break such as a courtyard or recessed entry, except where <br /> c district. <br />Garages Doors and Loading Docks: <br />I. Loading docks, refuse, <br />recyclables, and/or compactors shall be located on rear or <br />side facades and, to the extent feasible, garage doors should <br />be similarly located. Garage doors of attached garages on <br />a building front shall not exceed 50% of the total length of <br />the building front. Where loading docks, refuse, recyclables, <br />and/or compactors abut a public street frontage, a masonry <br />screen wall comprised of materials similar to the building, or <br />as approved by the Community Development Department, <br />Garage door placement <br />shall be installed to a minimum height to screen all activities. <br />Rooftop Equipment: <br />J. Rooftop equipment, including rooftop <br />structures related to elevators, shall be completely screened <br />from eye level view from contiguous properties and adjacent <br />streets. Such equipment shall be screened with parapets <br />or other materials similar to and compatible with exterior <br />materials and architectural treatment on the structure being <br />served. Horizontal or vertical slats of wood material shall <br />not be utilized for this purpose. Solar and wind energy <br />equipment is exempt from this provision if screening would <br />interfere with system operations. <br />1005.03 Table of Allowed Uses <br /> <br />Table 1005-1 lists all permitted and conditional uses in the <br />commercial and mixed use districts. <br />A. Uses marked as PŽ are permitted in the districts where <br />designated. <br />B. Uses marked with a CŽ are allowed as conditional uses in the <br />districts where designated, in compliance with all applicable <br />standards. <br />C. Uses marked as NPŽ are not permitted in the districts where <br />designated. <br /> c <br />standards must be complied with, whether the use is <br />permitted or conditional. Standards for permitted uses <br /> <br />