Laserfiche WebLink
� <br />■ Research, design and development. <br />■ Bank and financial institutions. <br />■ Health clubs <br />■ Restaurants <br />■ Retail sales <br />. <br />■ Day care centers <br />■ Parking to accommodate uses in a contiguous mixed use business district <br />■ Multi-family housing. <br />7.0 SITE CHARACTERISTICS/DEVELOPMENT PROPOSAL: <br />7.1 The subject property is 6.35 acre property in size and is currently platted as two parcels <br />with separate, but related, owners. The site is currently a primarily wooded site with one <br />single-family residence at its west end. There are portions of two designated wetlands on <br />the site (one on the north side of the property includes 20,301 sq. ft. of wetland area on <br />the site and the other on the south side includes 905 sq. ft. of�wetland on the site.) <br />7.2 The proposal seeks to develop a 4-story elongated 93-unit age-restricted cooperative <br />housing development located at the south end of the site and favoring the east side of the <br />property. As currently proposed the development would be accessed from Cleveland <br />Avenue North approximately mid-point between County Roads C2 and D. The proposed <br />primary access would serve three purposes; to provide access to a below grade parking <br />structure located beneath the building, to access an at-grade resident/guest parking lot, <br />and to provide access to the adjacent Langton Lake Park parking lot. <br />7.3 The applicants have indicated a willingness to augment the existing trees on the north <br />side of their property with the planting of additional trees in an effort to provide a visual <br />screen from the proposed road and development. They have indicated that berming <br />would be possible, but not preferable, as it would require the removal of� mature trees in <br />order to raise the surface elevation. <br />8.0 PUBLIC INFRASTRUCTURE: <br />8.1 The site would include landscaping and pedestrian connection to sidewalks and trails <br />(though not specifically indicated in the plans). All site detail would need to be <br />consistent with the Roseville City Code and or the Twin Lakes Design Principles. <br />8.2 The proposal could rely on existing public sanitary sewer and water located within the <br />Cleveland Avenue right-of-way. Lateral extensions sized appropriately for each use <br />could be extended to the final structure location. <br />8.3 When considering redevelopment areas such as Z�win Lakes, however, a single <br />redevelopment site must be considered under the context of a larger geographic area. <br />Specifically, watermain throughout Twin Lakes must be looped to eliminate dead end <br />lines and possible pressure losses. Such a system relies on good efficient design most <br />likely being provided via a lateral extension form an improved Twin lakes Parkway and <br />PF07-006_ RCA_061807 Page 5 of 9 <br />