My WebLink
|
Help
|
About
|
Sign Out
Home
pf07-063
Roseville
>
Planning Files
>
2007
>
pf07-063
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/29/2014 11:39:25 AM
Creation date
6/19/2013 3:33:38 PM
Metadata
Fields
Template:
Planning Files
Planning Files - Planning File #
07-063
Planning Files - Type
Zoning Text Amendment
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
83
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
"I'o assess the potential maximum peak noise condition, the dogs were all purposely agitated into <br />a barking frenzy during each sampling episode. This was accomplished by several persons <br />physically n►nning up and down the aisles between the kennels. Based on the pre-test <br />observations, this level of noise would never be achieved due to the constant care and attention <br />given to the occupants of the hotel by the large staff of PetSmart care givers. However, as a result <br />of the experiment the peak noise level measured at any given moment inside the hotel was: <br />Store # 0157 - 7290 W. Bell Rd. 104.6 dBA <br />Store # 0131 - 10825 Tatum Blvd 109.2 d8A <br />In addition to the indoor measurements, exterior measurements were also obtained at the <br />same time. These outdoor measurements provide a comparable measurement between the indoor <br />noise level and therefore the amount of noise level transfer. The outdoor measurements were <br />obtaiized from within twenty feet (20') feet of the front of the btiilding, within 1 foot of the rear <br />door contiguous to the liotel area, at a distance of fiCty feet (50'} from the rear of the building, at a <br />distance of fifty feet (SU') from an exterior wall contiguous to the space occupied by the dogs and <br />from the roof above the pets hotel space. Tl�e results were as follows: <br />Daytime <br />Position Ambient <br />Front of Building 53 dBA <br />i�acic of �3uilding <br />�at the rear door) 48 dBA <br />50' Back of Building 48 dBA <br />West Side of <br />Building <br />West Side of <br />Building 50' <br />Store #0157 <br />7290 W. Bell Rd. <br />Barking <br />Not Audible <br />Barely Audible <br />Not measurable <br />Not Audible <br />Nighttime <br />Ambient Barking <br />72 dBA2 Not Audible <br />52 dBA3 Not Audible <br />48 dBA Not Audible <br />Barely Audible <br />50 dBA Not measurable 54 dBA <br />50 dBA Not Audible 54 dBA <br />Roof 65 dBAI Not Audible 65 dBAI <br />Barely Audible <br />Not measurable <br />Not Audible <br />Audible <br />Not measurable <br />
The URL can be used to link to this page
Your browser does not support the video tag.