Laserfiche WebLink
'�� <br />—•. <br />GENERAL REQUIREMENTS <br />shall be removed, replaced or changed in a manner that reduces <br />its effectiveness as a safety barrier. <br />SECTION 304 <br />EXTERIOR STRUCTURE <br />304.1 GeneraL The exterior of a structure shall be maintained <br />in good repair, stnicturally sound and sani[ary so as not to pose <br />a threat to the public health, safety or welfare. <br />304.2 Protective treatment. All exterior surfaces, including <br />but not liinited to, doors, door and window frames, cornices, <br />porches, trim, balconies, decks and fences shall be main[ained <br />in good condition. Exterior wood surfaces, other than decay-re- <br />sistant woods, shall be protected from the elements and decay <br />by painting or othei• protective covering or treatment. Peeling, <br />flaking and chipped paint shall be eliminated and surfaces re- <br />painted. A]1 siding and masonry joints as well as chose between <br />the building envelope and the perimeter of windows, doors, and <br />skylights shall be maintained weather resistant and water tight. <br />Al] metal surfaces subject to rust or corrosion shall be coated to <br />inhibit such rust and corrosion and all surf�aces with rust or cor- <br />rpsipn chall he s(�tiili7_ed a_nr� rpgteC� t0 1nh!bit fUt�l-e :�5; 2^� <br />corrosion. Oxidation stains shall be removed from exterior sur- <br />faces. Surfaces designed for stabilization by oxidation are ex- <br />empt from this requirement. <br />[F] 304.3 Premises identification. Buildings shal] have ap- <br />proved address numbers placed in a position to be plainly legi- <br />ble and visibla from the street or road i'ronting the property. <br />These nui��c�rs shatl contra.et with theu background. Address <br />nuinbers shall be Arabic numerals or alphabet letters. Numbers <br />shall be a minimum of 4 inches (102 mm) high with a minimum <br />stroke width of 0.5 inch (12.7 mm). <br />304.4 Structural members. A]I structural members shall be <br />maintained free from deterioration, and shall be capable of <br />safely supportinD the imposed dead and ]ive loads. <br />304.5 Founda6on walls. All foundation walls shall be main- <br />tained plumb and free from open cracks and breaks and shal] be <br />kept in such condition so as [o prevent [he entry of rodents and <br />other pests. <br />304.6 Exterior walls. A]l exterior walls shali be free from <br />holes, breaks, and loose or rotting materials; and maintained <br />weatherproof and properly surface coated where required to <br />prevent deterioration. <br />304.7 Roofs and drainage. The roof and flashing shall be <br />sound, tight �nd not have defects that admit rain. Roof drainage <br />shall be adequate to prevent dampness or deteriorarion itt the <br />walls or interior portion of the structure. Roof drains, gutters <br />and do;�:L,� ntits shall be maintained in good repair and free <br />from oL�t?��tions. RooFwater shall not be discharged in a man- <br />ner that creates a public nuisance. <br />304.8 Decorative features. All cornices, belC courses, corbels, <br />terra cotta triin, wall facings and similar decorative features <br />shall be maintained in good repair with proper anchorage and <br />in a safe condition. <br />304.9 Overhang extensions. AIl overhang extensions includ- <br />ing, but not limited to canopies, marquees, signs, metal awn- <br />ings, fire escapes, standpipes and exhaust ducts shall be <br />�o <br />maintained in good repair and be properly anchored so as to be <br />kept in a sound condition. When required, all exposed surfaces <br />of inetal or wood s6a11 be protected from the elements and <br />against decay or rust by pe�iodic application of weather-coat- <br />ing materials, such as paint or similar surface treatment <br />304.10 Stairways, decks, porches and balconies. Every exte- <br />rior stairway, deck, porch and balcony, and all appurtenances <br />attached thereto, shall be maintained structurally sound, in <br />good repair, ��ith proper anchorage and capable of supporting <br />the imposed loads. <br />304.11 Chimneys aud towers. All chimneys, cooling towers, <br />smoke stacks, and similar appurtenances shall be maintained <br />s[nicturally safe and sound, and in good repair. All exposed sur- <br />faces of inetal or wood shall be protected from the elements and <br />against decay ar rust by periodic application of weather-coat- <br />ing maierials, sucl� as paint or similar surface krea[ment. <br />304.12 Handrails and guards. Every handrail and guard shall <br />be fumly fastened and capable of supporting normally imposed <br />loads and shall be maintained in good condition. <br />304.13 Window, skylight ar�d door frames. Every window, <br />s;c�lig ;t, door aad irame siiatl oe xepi in sound condition, good <br />repair and weather tight. <br />3fl4_13.1 Glazing. All glazing materials shall be maintained <br />free fro�n cracks and holes. <br />304.13.2 Openable windows. Every window, other than a <br />fixed window, shal; be easily openable and capable of being <br />held in positioa b� window hardware. <br />304.14 Insect screens. During the period from [DA7'E) to <br />[DATE], every door, window and oiher outside opening required <br />for ventilation of habi[able rooms, food preparation areas, food <br />seivice areas or any areas where products to be included or uti- <br />lized in food for human consumption az�e processed, manufac- <br />tured, packaged or stored, shal] be supplied with approved <br />Ughtly fitting screens of not less than 16 mesh per inch (16 <br />mesh per 25 mm) and every swinging door shall have a self- <br />closing device in good working condition. <br />Exception: Screens shall not be required where other ap- � <br />proved means, such as air cur[ains or insect repellent fans, <br />are employed. <br />304.15 Doors. All exterior doors, door assemblies and hard- <br />ware shall be maintained in good condition. Locks at all en- <br />trances [o dwe]ling units, rooming units and gues�ooms shall <br />tightly secure the door. Locks on means of egress doors shall be <br />in accordance with Sectio� 702.3. <br />304.16 Basement hatchways. Every basement hatchway shall <br />be maintained to prevent the entrance of rodents, rain and sur- <br />face drainage water. <br />304.17 Guards for basement wvindows. Every basement win- <br />dow that is openable shall be supplied with rodent shields, <br />storm windows or o[her approved protection against the entry <br />of rodents. <br />304.18 Building security. Doors, windows or hatchways for <br />dwelling units, room units or hovsekeeping units shall be pro- <br />vided with devices designed [o provide security for the occu- <br />pants and property within. <br />2003 INTERNATIONAL PROPERTY MAINTENAtJCE CODEC� <br />