Laserfiche WebLink
8. Tlle minimum parameters of a setback permit include: <br />a. A setback permit shall not reduce the principal structure side yard required <br />setback by more than 70% or be closer than three (3) feet to a property line <br />(as measured to the structure wall). <br />b. A setback permit shall not reduce the principal structure front or rear yard <br />required setback by more than 20% or be closer than twenty-four (24) feet to <br />a front or rear property line. <br />c. A setback permit shall not reduce the accessory structure side or rear yard <br />required setback by more than 70% or be closer than three (3) feet to a <br />property, line. <br />d. A setback permit shall not reduce the setback of a driveway by more than <br />70% or allow a driveway to be closer than two (2) feet to a property line. As <br />an exception, driveways existing prior to October 26, 1998, and located closer <br />than two (2) feet to a property line may be replaced with a setback permit. <br />9. A minimum of eight (8) of the following twelve (12) site conditions must be met in order or a <br />Setback Permit to be issued by the Community Development Director. Circle which havc been <br />complied with and explain how compliance has been achieved. <br />a. One car gar•age or less is located on the site. <br />b. The proposed pr•oject improves the design or livabiliry of the strarcta�re. <br />c. The proposed project improves the terr�ain or a drainage issue. <br />d. The original reason or need for the setback permit was not created by the current <br />owner. <br />e. The existing improvements along with proposed improvement retain a minimum of <br />70% of the pervious surface and green space of the lot. <br />f. The proposed project creates no other setback or variarrce conditions. <br />g. The proposed project improves the aesthetics, covered stor-age, or the,fiinctios�al <br />arse �f the site. <br />h. The proposed project uses the same exterior ,structure materinls and colors ns the <br />�rincipal structu�-e anci acces:sorres. <br />i. The final building mass is consistent with that on contiguous properties. <br />j. The building or driveway expansion/addition does not place more vehicles <br />adjacent to living quarter first floor bedrooms of adjacent homeowners. <br />k. The drainage and roof gutters guide water away from the structzrre and adjncent <br />structures. <br />1. The roof is properly proportioned to and integrated with the roof qf the principal <br />structure (dwelling) on the properly. <br />10. The following information/materials must be submitted by the applicant (and determined <br />complete by the Community Development Director) ten (10) days before the application may be <br />considered by the Developmcnt Review Committce: <br />a. Application and fee of $75. <br />Page 2 <ir 3 <br />