Laserfiche WebLink
<br />Any Existing Grading/Drainage/Erosion Concerns ? <br />NO <br />YES <br /> <br />_The plans showing the proposed storm sewer· at the _____ <br />Southeast corner of the lot extending into private <br />- <'----- <br />_railroad property. An easement 1S required over that_ <br />-part of the lot if it is built as shown. <br /> <br />x <br />-- <br /> <br />Drainage Facilities <br /> <br />Existing <br /> <br />To Be Built <br /> <br />x <br /> <br />Storm Sewer Main <br /> <br />Ponding Area <br />Catch Basins <br /> <br />x <br /> <br />Describe Grading/Drainage/Erosion control plan: _The erosion control <br />_fence as shown is required during grading operations. <br /> <br />Any utility Concerns? NO <br /> <br />YES X <br /> <br />-- <br /> <br />utility Facilities Existing To Be Built <br />Water Main X <br />Water Service X <br />Sanitary Sewer Main X <br />Sanitary Sewer Servo X <br /> <br />Describe utility Service Plans: _The proposed sanitary sewer main runs <br />_across two lots. An easement is needed if it is built this way. The_____ <br />-proposed water main needs a wet tap on the existing 12" city main located_ <br />_in County Road C. A permit from Ramsey County is required. The proposed_ <br />hydrant should be placed on the east side of the proposed new driveway. <br /> <br />Any Curb and Gutter to be Removed? <br /> <br />NO <br /> <br />YES X <br />-- <br /> <br />Any Road/Parking Facilities Concerns? NO <br /> <br />YES <br /> <br />X <br /> <br />Describe Road/Parking lots to be built: The proposed new driveway location <br />needs to be built so it meets a set backs. <br /> <br />Page 2 <br />