My WebLink
|
Help
|
About
|
Sign Out
Home
pf_02471
Roseville
>
Planning Files
>
Old Numbering System (pre-2007)
>
PF2000 - PF2999
>
2400
>
pf_02471
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2007 11:53:18 AM
Creation date
12/8/2004 11:32:39 AM
Metadata
Fields
Template:
Planning Files
Planning Files - Planning File #
2471
Planning Files - Type
Planned Unit Development
Address
674 COUNTY ROAD C W
Applicant
PARKRIDGE DEVELOPMENT
Status
WITHDRWN
PIN
112923110007
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
192
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />/IIJ~, I~ <br /> <br />May 18. 1994 <br /> <br /> <br />AI Kehr <br />988 W. County Road D <br />Rosevi11e, MN 55113 <br /> <br />RE: PARTRIDGE RIDGE STORM SEWER PLAN REQUIREMENTS <br /> <br />Dear Mr. Kehr: <br /> <br />Thank you for meeting with us to discuss stonn sewer issues related to your proposed townhome <br />project near County Road C and Dale Street. Based on our discussion, we uilderstand that you <br />are working with George Reiling. the property owner of the southeast quadrant of County Road <br />C and Dale Street. to develop a joint stonnwater detention area to serve both your development <br />and Mr. Reiling's future development. Generally spca1ång. the development ofrcgional ponding <br />areas can be consnucted more efficiently and provide better stormwater treatment than small on- <br />site facilities. . <br /> <br />The purpose oftbis letter is to outline the stormwater design information that we wi11 need to <br />review your P.U.D. application. The purpose of this infonnation is to demonstrate that the <br />proposed drainage system wiD work. Detailed storm sewer design plans are not needed as part of <br />the P.U.D. approval. It should be noted. however, that detailed plans wiUbe required before a <br />building pennit is issued. The following is a list of drainage information needed for P.ll.D. <br />approval: <br /> <br />~ The proposed on-site stonn sewer system should be shown on the site utility plan. This <br />should include pipe sizes, catch basin locations, and pipe invert elevations. <br /> <br />~ An exhibit that shows the connection of your site to George Reiling's site east ofDaJe <br />Street. This exhibit should detail pipe location and pipe size. <br /> <br />~ An exhibit that shows the size. rough grading. and location of the proposed stormwater <br />po~d on George Reiling's property. The purpose of this exhibit is to show that a pond <br />large enough to fulfill the needs of your site, as well as George Reiling's, can reasonably be <br />fit on the property. <br /> <br />. Stonn sewer calculations that show how the proposed pond was sized. The pond should <br />provide flood storage for a lOO-year rain event for both your property and George <br />Reilings property. The calculations should assume that Mr. Reiling's property is <br />developed. The outlet for the pond should be designed to limit the rate of runoff to an <br />existing 10-year event. <br /> <br />2660 CIVIC CI~NTI~H I>RIVI~ · HOSRVJLL)~. MINN)~S01'A · 55J 13·H.!99 <br />(d2.4<JO-2200. TDD ()]2·490-2205 <br />
The URL can be used to link to this page
Your browser does not support the video tag.