My WebLink
|
Help
|
About
|
Sign Out
Home
pf_02685
Roseville
>
Planning Files
>
Old Numbering System (pre-2007)
>
PF2000 - PF2999
>
2600
>
pf_02685
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2007 12:04:12 PM
Creation date
12/8/2004 12:14:59 PM
Metadata
Fields
Template:
Planning Files
Planning Files - Planning File #
2685
Planning Files - Type
Planned Unit Development
Address
1716 HAMLINE AVE N
Applicant
KENTFIELD, SANDRA
Status
APPROVED
PIN
152923430042
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
52
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />From: <br /> <br />Mike Falk <br />Douglas Strong~ <br />Planning File #2688 <br /> <br />To: <br /> <br />Re: <br /> <br />Date: August 2, 1994 <br /> <br />This file deals with a PUD at 2131 Fairview Avenue. The <br />engineering staff has reviewed this proposal and has the <br />following recommendations: <br /> <br />1. Site plan does not show a sidewalk on Fairview Avenue <br />south of the proposed new driveway. The proposed new <br />sidewalk north of the driveway is shown as 5 feet and <br />it should be 6 feet. <br /> <br />2. Need storm sewer calculations for the proposed storm <br />sewer line to the proposed new pond. The parking lot <br />needs some catch basins within the parking lot to pickup <br />the runoff Defore it gets to the two new proposed catch <br />next to Fairview Avenue. The two catch basins could not <br />handle that must water. Two catch basins should be built <br />at the property line of the existing driveway to the north. <br /> <br />3. The water service connection needs to be looked at. <br />There is an existing tee which could be changed to a <br />cross to serve the proposed new building. <br /> <br />4. The proposed sanitary sewer service elevation needs to <br />be checked with the existing storm sewer that runs <br />parallel with Fairview Avenue. The sanitary sewer must <br />run under the storm sewer. <br /> <br />5. The landscaping plan needs to be overlaid onto the <br />utility plans to make sure trees are not planted on top <br />of any of the utilities. <br /> <br />6. The northwesterly driveway opening is shown at 22 feet <br />and should be 24 feet. <br />
The URL can be used to link to this page
Your browser does not support the video tag.