Laserfiche WebLink
<br />I, <br />Ii <br />I,j <br />,I} <br />'1\ <br /> <br />, . <br /> <br /> <br /> <br />-Ii <br />'IJ\ , <br /> <br />I}- <br /> <br />11 <br />IJ <br />t} <br />IJ <br />IJ <br />'IJ <br />.IJ <br />IA <br />II <br />i <br />i <br /> <br />400-1 <br /> <br />S:e:CT~ON 4Q~' - SANIT~Y SEWER <br /> <br />400. 0 . - a:1Ji~~~Y SEQR <br /> <br />401.0 _,~sqription <br /> <br />This work shall consist of the construotion of pipe sewers <br />. utilizing plant fabricated pipe and other appurtenant,materials, <br />installed for conveyanoe of sewage or industrial wastes. The <br />work includes construction of manhole structures and,other <br />related items as specified. <br /> <br />All references to MnDOT ,specifications shall mean the latest <br />published edition of the Minnesota Department ,of ~ransportation <br />-standard Specifications for Highway Construction, as modified by <br />any MnDOT Supplemental Speoifications edition ,published prior to <br />the date of advertisement for bids. All references to other <br />Specifications of 'AAsBTO, ASTM, ANSI, AWWA., etc. shall mean the <br />latest published edition available on the date of advertisement <br />for bids. <br /> <br />402.0 ~~~~IALS <br /> <br />All materials required for this work shall be new material <br />conforming to requirements of the referenced spec~fic~tions for <br />the class, kind, type,'size, grade, and other details indicated <br />in the Contract. ' Un~ess otherwise, in4icated, all, required <br />materials shall be furnished by the- CONTRACTOR.' If any options <br />are provided for, as to type, grade, or ' ,design of the material, <br />the choice shall be limited as may be stipulated in the Plans or <br />Special Provisions. <br /> <br />'~':' ,',' All manufactured' produets shall confon in detai'l ~o sUQh <br />standard design drawings as may be'referenoed or furnished in <br />,the Plans. o'therwise, the Department may require advanc~ <br />approval of material suppliers, product design, or other <br />unspecified details as it deems desirable for maint~ining <br />adopted standards. <br /> <br />402.1 ~ <br /> <br />All pipe furnished f~r main sewer and servioe line installations <br />shall be,of the type, 'kind, size, and class 'indicated for each <br />particular line segment as 'shown in the p~ans and designated in <br />: the Contract. IteJls. Wherever connection of dissimilar materials <br />, . ,or designs is reciui~ed, 'the~ method of joining and any special <br />tittin9s employed shall be subject t() approval by the ENGINEER. <br /> <br />All a" and-l0" sanitary sewer pj,pe shall be either V.C.P., <br />A.S.T.H. Designation C-200-T (extra strength)or_PVC, A.S.T.M. <br />D-3034~72. Pipe'and,fitting~ shall meet extra strength minimum <br />of DRS-35. <br /> <br />Material service connections shall be 4" C.I.S.P. extra-heavy <br />rl;,,(.~, ;;: weight, ASTH 1-8, ASTM A-438, AsTM A-126 or 4" PVC, Class 150, <br />(: 'd'f~:{>~,!,,) ASTM D-2241. <br />