My WebLink
|
Help
|
About
|
Sign Out
Home
pf_02976
Roseville
>
Planning Files
>
Old Numbering System (pre-2007)
>
PF2000 - PF2999
>
2900
>
pf_02976
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2007 12:26:35 PM
Creation date
12/8/2004 1:55:40 PM
Metadata
Fields
Template:
Planning Files
Planning Files - Planning File #
2976
Planning Files - Type
Planning-Other
Address
2800 ARONA ST
Applicant
ARONA DEVELOPMENT
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
243
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />1.0 INSPECTION SUMMARY <br /> <br />The asbestos inspection of the NCR Comten Training Center found <br />the following aSbestos-containing materials and approximate <br />quantities: <br /> <br />1. Thermal Systems Insulation = 120 Fittings <br /> 10 Linear Feet <br />2. Thermal Water Heater Insulation = 210 Square Feet <br />3. Floor Tile (9" x 9") = 7,500 Square Feet <br /> <br />These materials have isolated damage and should be repaired or <br />removed. <br /> <br />All but about 10 linear feet of pipe insulation was determined to <br />be nonasbestos. <br /> <br />2.0 INSPECTION HETHODS <br /> <br />The asbestos inspection of the NCR <br />facility was conducted by Mr. Mark <br />inspector and management planner. <br />conducted on May 17, 1991. <br /> <br />The ~urpose of the ins~ection was to identify, quantify, evaluate <br />cond1tion of, accessib1lity of, and indicate location of <br />aSbestos-containing materials (ACM)--both friable and nonfriable <br />types. <br /> <br />Comten Training Center <br />Sonaglia a certified asbestos <br />Inspection of the facility was <br /> <br /> <br />Floor plans for the facility were provided br HCR Comten to <br />provide recordkeeping by mapping the sample ocation of the <br />suspect materials. <br /> <br />The entire facility was inspected for suspect aSbestos-containing <br />laterials. Sus~ect ACM {such as thermal insulation on pipes, and <br />other hot/cold 1tems, ce1ling and floor tile, ceiling panels, and <br />hardboard sheeting) was observed, touched, representatively <br />sampled, and submitted to Braun Laboratories for analysis to <br />~etermine the percent concentration and type of asbestos (if any) <br />In the samples. Location of sam~les are shown on the <br />accompanying figures. Refer to F1gures 1-6. <br /> <br />~t is possible that not all the ACM in the facility was <br />dentified. For example, roofing materials, non-accessible <br />iling plenums, and pipe chases inside walls. If any insulation <br />terial is encountered that does not ap~ear in this report, <br />t resembles ACM, that particular mater1al should be <br />aluated either by visual or if necessary, analytical means to <br />termine that it aoes or does not contain asbestos. <br /> <br />COK'l'DJ ASBESTOS RBPORT <br /> <br />PAGB 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.