My WebLink
|
Help
|
About
|
Sign Out
Home
pf_03225
Roseville
>
Planning Files
>
Old Numbering System (pre-2007)
>
PF3000 - PF3801
>
3200
>
pf_03225
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/14/2011 10:06:02 AM
Creation date
12/9/2004 6:53:56 AM
Metadata
Fields
Template:
Planning Files
Planning Files - Planning File #
3225
Planning Files - Type
Planned Unit Development
Address
2599 Lexington Ave N
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
714
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />of flood-prone areas and other nonwater ponding areas and so <br />that the interiors remain reasonably dry. <br /> <br />STAT AUTH: MS s 168.59 to 168.73 <br /> <br />HIST: 12 SR 2251 <br />Current as of 05/01/97 <br /> <br />1370.0180 UTILITY LINE HAZARDS. <br /> <br />Hazardous utility lines must not be located in or near a <br />storm shelter. The underground electrical service required by <br />part 1370.0200 is exempt from this requirement. <br /> <br />STAT AUTH: MS s 168.59 to 168.73 <br /> <br />HIST: 12 SR 2251 <br />Current as of 05/01/97 <br /> <br />1370.0190 MINIMIZING FIRE DANGER. <br /> <br />Storm shelters must be constructed to minimize the danger <br />of fire from both external and internal sources. <br /> <br />STAT AUTH: MS s 168.59 to 168.73 <br /> <br />HIST: 12 SR 2251 <br />Current as of 05/01/97 <br /> <br />1370.0200 ELECTRICAL POWER. <br /> <br />Underground electrical service must be provided to a storm <br />shelter. <br /> <br />STAT AUTH: MS s 168.59 to 168.73 <br /> <br />HIST: 12 SR 2251 <br />Current as of 05/01/97 <br /> <br />1370.0210 ILLUMINATION. <br /> <br />Subpart 1. ~nimum illumination. At least five foot <br />candles of illumination must be provided at floor level. <br /> <br />Subp. 2. Source. An emergency lighting system must be <br />supplied from storage batteries or an on-site generator <br />installed in accordance with the requirements of the National <br />Electrical Code, incorporated by reference in chapter 1315. <br /> <br />STAT AUTH: MS s 168.59 to 168.73 <br /> <br />HIST: 12 SR 2251 <br />Current as of 05/01/97 <br /> <br />1370.0220 VENTILATION. <br /> <br />Ventilation must comply with the criterion on page nine of <br />the interim guidelines incorporated in part 1370.0130. <br /> <br />STAT AUTH: MS s 168.59 to 168.73 <br /> <br />HIST: 12 SR 2251 <br />Current as of 05/01/97 <br />
The URL can be used to link to this page
Your browser does not support the video tag.