<br />4.0 RECOMMENDA TIONS <br /> <br />Based on the survey of the Roseville Activity Center, located at 2800 Arona A venue in <br />Roseville, Minnesota, conducted on August 24, 200n, DPRA makes the following <br />recommendations: <br /> <br />4.1 <br /> <br />Asbestos <br /> <br />This survey was conducted to locate asbestos-containing materials that must legally be <br />removed prior to demolition of the building. Regulations require that all ACM which are <br />friable or will become friable during demolition must be removed from the building prior <br />to demolition by a licensed asbestos abatement contractor. <br /> <br />ACM does not need to be removed prior to demolition if it meets one of the following <br />criteria: (a) it is a Category I non-friable ACM that is not made friable during the <br />demolition process; (b) it is a component that is encased in concrete or other similarly <br />hard material and is adequately wet whenever exposed during demolition; (c) it was not <br />accessible for testing and therefore was not discovered until after demolition began and, <br />as a result of the demolition, cannot be safely removed; or (d) it is a Category II non- <br />friable ACM and the probability is minimal that the material will become crumbled, <br />pulverized, or reduced to powder during demolition. If ACM is not removed because of <br />safety reasons, the exposed RACM and any asbestos-containing debris must be treated as <br />asbestos-containing waste material and kept adequately wet at all times until disposed. <br /> <br />The following asbestos-containing materials must be removed from the building prior to <br />demolition: <br /> <br />Damaged 9" by 9" floor tile in the gymnasium and back hallway. (3,210 square <br />feet) <br />Transite boards around courtyard, along teen room, and around exterior of <br />gymnasium. (1,380 square feet) <br />Air Conditioner Insulation on the rooftop units. (-20 units, 50 square feet each) <br /> <br />The following materials are allowed to remain in place during building demolition per <br />MPCA regulations but must be disposed of properly: <br /> <br />Floor tile and mastic in good condition <br />Caulk <br />Roof Seam Cover <br />Roof Tar <br /> <br />However, if the concrete is to be recycled, all floor tile and mastic must be removed from <br />the building prior to demolition. <br /> <br />12 <br /> <br />Demolition Asbestos Survey <br />DPRA Project No. 5781.0002.0001 <br />September 15, 2000 <br /> <br />Roseville Activity Center <br />Roseville, MN <br />