My WebLink
|
Help
|
About
|
Sign Out
Home
pf_03315
Roseville
>
Planning Files
>
Old Numbering System (pre-2007)
>
PF3000 - PF3801
>
3300
>
pf_03315
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/26/2007 12:15:24 PM
Creation date
12/9/2004 7:24:20 AM
Metadata
Fields
Template:
Planning Files
Planning Files - Planning File #
3315
Planning Files - Type
Conditional Use Permit
Address
803 LARPENTEUR AVE W
Applicant
Roselawn Cemetery
Status
Denied
Date Final City Council Action
8/27/2001
Planning Files - Resolution #
9927
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
318
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />Emission Test Report <br />EMC WA-2-08 <br />Section 3 <br />Revision: 0 <br />Date: September 30,1999 <br />Page 6 of 33 <br /> <br />that Run 1 inlet results are low by a factor of 10 compared to Runs 2 and 3. As is <br />commonly observed, data show a trend for increased dioxinlfuran amounts at the outlet <br />compared with the inlet. There is also a trend for increased dioxinlfuran amounts as SCC <br />temperatures are increased. <br /> <br />I <br />I <br /> <br />3.4.5 Results of O2, CO2, S02' NOx, and CO Analysis and Opacity <br />Observations <br /> <br />Continuous instrumental analyzers were used for the duration of a cremation to <br />measure scrubber inlet and outlet emissions of O2, CO2, 502, NOx, and CO. A concurrent <br />visible emissions evaluation for opacity was also performed at the chimney outlet. Results <br />of continuous instrumental analyzers monitoring and opacity observations are presented in <br />Table 3-25. <br /> <br />The Run 5 cremation in Unit 4 started 30 minutes before the end of a cremation in <br />Unit 1. For the first 30 minutes of Run S, therefore, visible emissions recorded may not <br />reflect the true visible emissions from Unit 4 only. <br /> <br />The S02' NOx. and CO instrumental analyzers occasionally recorded gas concentration <br />spikes that exceeded their span. At the end of the test program, the linearity of the <br />analyzers at higher concentrations was demonstrated by using a calibration gas above the <br />highest one-minute average spike measured during the test program. Calibration gas was <br />introduced at the sampling probe, and linearity was demonstrated to meet the accuracy and <br />calibration error requirements of Methods 6C. ?B, and 10 in Appendix A of 40 CFR 60. <br />Data from the post-test linearity checks are contained in Appendix J. <br /> <br />3.4.6 Process Data <br /> <br />Process test data and a summary of body/contai~er characteristics are provided in <br />Tables 3-26 and 3-27, respectively. Process data collection forms are found in <br />Appendix B. As denoted in the process data Table 3-26, no ambient odors were noticeable <br />near t~e crematory. However, a slight foul odor could be observed by passersby near the <br />down draft of the stack during the first 2 to 3 minutes. <br /> <br />I <br /> <br />MRI-AED\R49S 1-08-03 S3.wpd <br /> <br />~.. ; <br />, <br />i <br />
The URL can be used to link to this page
Your browser does not support the video tag.